- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT02761356
The Added Value of Hybrid Functional Anatomical Imaging PET-CT and SPECT-CT in Patients Treated With Y-90 SIRT for Liver Malignancies
The Added Value of Hybrid Functional Anatomical Imaging PET-CT and SPECT-CT in Patients Treated With Yttrium-90 SIRT for Liver
Patients cohort is composed of 50 consecutive patients both male and female with hepatic malignancies, refered to our nuclear medicine department in the process of radioembolization between January 2010- August 2015. 26 of the patients were examined with Tc99-MAA and SPECT-CT and 24 patients were examined with Tc99-MAA , SPECT-CT and PET-CT. Our study protocol was as follows:
- Collection of anamnestic data
- Calculation of liver tumor volume with quantification software
- Evaluation of the liver tumor involvement
- Evaluation of liver to lung shunt
- Calculation dose of SIRTEX
- Y90 imaging
- Follow Up
Przegląd badań
Status
Interwencja / Leczenie
Szczegółowy opis
The description of the various stages that the patient goes through SIRTex treatment in the department of nuclear medicine and their roll in the study is as following:
The first stage is dedicated to the evaluation of the patient's illegibility for the treatment.
- In Angiography department
- In Nuclear medicine department assessment of liver-lung shunting (planar images). Followed by SPECT-CT of the upper abdomen. SPECT with Low dose CT is used to identify a leak to the stomach, duodenum and mesentery, as well as to assess uptake of Tc-99m-MAA in tumor lesions. In order to increase SPECT-CT resolution and sensitivity we co-registrated SPECT-CT with diagnostic CT provided from previous contrast enhanced CT or PET-CT. In this procedure, the Low dose CT is used as bridge between diagnostic CT and the functional imaging SPECT.
- Calculation dose of Sirtex therapy. At this stage the purpose of the study will be to investigate the added value of SPECT-CT in the estimation of Tc-99m-MAA uptake in tumor lesions.
The second stage is dedicated to the assessment Y-90-SIRTex uptake in liver tumors and to exclude extra hepatic leak. Several hours after treatment patients perform SPECT-CT using Brummshtrullung emission or PET-CT with the peak Zr-90.
At this stage , in our study, we will compare liver lesions uptake of Tc-99m-MAA in the SPECT-CT to lesions uptake of Y-90 -SIRT SPECT/PET-CT as well as to assess if SPECT-CT withTc-99m-MAA may be used as a predictor of Y-90-SIRTex uptake in liver lesion. Does SPECT-CT with Tc-99m-MAA change patient managment.
The third stage of the study is the collection and monitoring of post treatment outcome data.
Typ studiów
Zapisy (Rzeczywisty)
Kontakty i lokalizacje
Lokalizacje studiów
-
-
-
Tel Aviv, Izrael
- Department of Nuclear Medicine, Tel Aviv Sourasky Medical Center
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Metoda próbkowania
Badana populacja
Opis
Inclusion Criteria:
- 1. Age ≥ 18. 2. Patients with malignancy of the liver (metastasis or primary tumor) who were treated with Y90 SIRT and were refered to the nuclear medicine department for a PET-CT.
Exclusion Criteria:
- 1. Age < 18. 2. Pregnant woman 3. Children and legally incompetent.
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
Kohorty i interwencje
Grupa / Kohorta |
Interwencja / Leczenie |
|---|---|
|
Tc99-MAA and SPECT-CT
26 of the patients were examined with Tc99-MAA and SPECT-C
|
To evaluate the fisibility of Tc99-MAA injected intra epatic artery to predict uptake of Yttrium-90 SIRT in patients with liver malignancies
Inne nazwy:
|
|
Tc99-MAA , SPECT-CT and PET-CT
24 patients were examined with Tc99-MAA , SPECT-CT and PET-CT.
|
To evaluate the fisibility of Tc99-MAA injected intra epatic artery to predict uptake of Yttrium-90 SIRT in patients with liver malignancies
Inne nazwy:
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Visual assesment of Tc-99m-MAA in liver lesions compared to visual assesment of Y-90 sirtex.
Ramy czasowe: one year
|
Undestanding the role of Tc-99- MAA in the prediction of Y90 sirt uptake in liver lesions by visual assesment with PET-CT and SPECT-CT imaging
|
one year
|
Współpracownicy i badacze
Sponsor
Śledczy
- Główny śledczy: Einat Even-Sapir, Phd, MD, Tel-Aviv Sourasky Medical Center
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów
Zakończenie podstawowe (Rzeczywisty)
Ukończenie studiów (Rzeczywisty)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Oszacować)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Oszacować)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- TASMC-16-ES-0413-15-TLV-CTIL
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .