- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT07784257
Diagnostic Accuracy of Triphasic Bone Scan and SPECT/CT in Foot and Ankle Osteoarthritis
Diagnostic Accuracy of Triphasic Bone Scan and SPECT/CT for the Evaluation of Foot and Ankle Osteoarthritis Using MRI as Reference Standard
Przegląd badań
Status
Szczegółowy opis
Osteoarthritis of the foot and ankle is a significant cause of chronic pain and functional impairment. Conventional radiography has limited sensitivity for early changes, while magnetic resonance imaging (MRI) is considered the reference standard for evaluating cartilage, bone marrow edema, and soft tissue structures.
Nuclear medicine techniques provide functional information about bone metabolism. Triphasic bone scan using technetium-99m methylene diphosphonate (99mTc-MDP) assesses perfusion, blood pool, and delayed skeletal uptake. However, planar imaging has limited spatial resolution and anatomical localization in the complex anatomy of the foot and ankle.
Hybrid SPECT/CT combines the functional data of SPECT with the precise anatomical localization of CT, improving diagnostic confidence and specificity. This study will evaluate the diagnostic accuracy of triphasic bone scan and SPECT/CT compared with MRI in patients with suspected foot and ankle osteoarthritis.
Typ studiów
Zapisy (Szacowany)
Kontakty i lokalizacje
Kontakt w sprawie studiów
- Nazwa: Amira A Ebraheem, resident
- Numer telefonu: 01212838177 01212838177
- E-mail: aaabbb10121999@gmail.com
Kopia zapasowa kontaktu do badania
- Nazwa: Mohamed A Mekawy, prof
- Numer telefonu: 01223196777 01223196777
- E-mail: M_mekkay51@yahoo.com
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
- Dorosły
- Starszy dorosły
Akceptuje zdrowych ochotników
Metoda próbkowania
Badana populacja
Opis
Inclusion Criteria:
Age ≥ 18 years
- Patients presenting with chronic foot and/or ankle pain suspected to be due to osteoarthritis
- Clinical and/or radiographic suspicion of foot or ankle osteoarthritis
Exclusion Criteria:
- Age < 18 years
- Previous surgery or joint replacement of the affected foot or ankle
- Bone tumors or metastatic bone disease
- Active osteomyelitis or septic arthritis
- Inflammatory arthropathies (e.g., rheumatoid arthritis, psoriatic arthritis, gout)
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Diagnostic accuracy of triphasic bone scan and SPECT/CT
Ramy czasowe: Baseline
|
Sensitivity, specificity, positive predictive value, and negative predictive value of triphasic bone scintigraphy and SPECT/CT for detecting foot and ankle osteoarthritis, using MRI as the reference standard.
|
Baseline
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Identification of affected joints
Ramy czasowe: Baseline
|
Determination of the specific joints affected by osteoarthritis in the foot and ankle based on SPECT/CT and MRI findings.
|
Baseline
|
Współpracownicy i badacze
Sponsor
Śledczy
- Krzesło do nauki: Mohamed A Mekawy, prof, assiut
Publikacje i pomocne linki
Publikacje ogólne
- Freeman LM, Donald Blaufox M. Seminars in Nuclear Medicine March 2019. Semin Nucl Med. 2019 Mar;49(2):83-84. doi: 10.1053/j.semnuclmed.2018.11.003. Epub 2018 Dec 6. No abstract available.
- Expert Panel on Musculoskeletal Imaging; Tafur M, Bencardino JT, Roberts CC, Appel M, Bell AM, Gyftopoulos S, Metter DF, Mintz DN, Morrison WB, Small KMS, Subhas N, Weissman BN, Yu JS, Kransdorf MJ. ACR Appropriateness Criteria(R) Chronic Foot Pain. J Am Coll Radiol. 2020 Nov;17(11S):S391-S402. doi: 10.1016/j.jacr.2020.09.015.
- van Hasselt AJ, de Vries AJ, de Zwart AD, Reininga IHF, Jutte PC, van Raaij TM. Diagnostic accuracy of 99mTc-HDP SPECT/CT and MRI for foot and ankle osteoarthritis (ProSPECT-trial): Study protocol. Foot Ankle Surg. 2025 Jul;31(5):443-447. doi: 10.1016/j.fas.2025.01.008. Epub 2025 Jan 19.
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Szacowany)
Zakończenie podstawowe (Szacowany)
Ukończenie studiów (Szacowany)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- Foot-Ankle-OA-SPECTCT-2026
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .