- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT07785024
CEST for Prostate Biopsy
Advanced Metabolic MRI to Refine Targeted Prostate Biopsy
Przegląd badań
Status
Warunki
Interwencja / Leczenie
Szczegółowy opis
Prostate Imaging and Data Reporting System assessment categories positively correlate with an increased likelihood of detecting clinically significant prostate cancer (csPCa) at targeted biopsy1. A PI-RADS assessment category 3 (intermediate, clinically significant cancer likelihood equivocal) lesion is often not csPCa. Studies evaluating the likelihood of csPCa cancer at targeted biopsy of PI-RADS category 3 lesions have reported variable rates of PCa diagnosis, ranging from 5-30%, with the majority of studies showing a relatively low likelihood of eventual csPCa diagnosis2-4. Management of PI-RADS category 3 lesion is variable, ranging from immediate biopsy to surveillance5,6. Given the disparity in management patterns for PI-RADS category 3 lesions and a small but not insignificant proportion of these lesions harboring csPCa, better classification of category 3 lesion is an unmet need. Previous studies in these patients have shown a correlation of csPCa with older patient age, smaller prostate volumes, higher prostate-specific antigen density (PSAD), and increased clinical stage7-11.
In this study, we will investigate the ability of magnetization transfer (MT) and chemical exchange saturation transfer (CEST) magnetic resonance imaging (MRI), without the use of any injected contrast agent, in conjunction with multiparametric magnetic resonance imaging (mpMRI) to aid in the detection of cancer, risk stratification and to decide whether a targeted prostate biopsy is justified. In this study, we propose to use the following ST-MRI techniques:
- Chemical Exchange Saturation Transfer (CEST) to probe changes in tumour metabolism.
- Magnetization Transfer (MT) to evaluate tumour environment microstructure.
Up to five healthy volunteers will be recruited for ST-MRI testing and estimation of test/re-test reproducibility. Testing of MR imaging protocols on healthy volunteers (without contrast agent) is required for optimization of sequence parameters including: higher signal intensity, higher contrast between tissue types, decreased scan time, and reduced image artifacts. There will be up to three MRI scans per healthy volunteer. MRI contrast agent will not be injected.
Patient recruitment will be performed at the Odette Cancer Centre. There will be one MRI scan per patient. All patients will undergo ST-MRI scans at Sunnybrook. ST-MRI parameter images including MTR, AREX, and quantitative MT model parameters, in addition to quantitative magnetization relaxation images will be used to identify areas of prostate with altered image contrast. Other quantitative and semiquantitative features will also be evaluated from the images. We hypothesize that ST-MRI will identify cancer suspicious areas that overlap with those identified by mpMRI and potentially additional areas.
Typ studiów
Zapisy (Szacowany)
Faza
- Nie dotyczy
Kontakty i lokalizacje
Kontakt w sprawie studiów
- Nazwa: Greg J Stanisz, PhD
- Numer telefonu: 416-480-5725
- E-mail: greg.stanisz@utoronto.ca
Lokalizacje studiów
-
-
Ontario
-
Toronto, Ontario, Kanada, M4N 3M5
- Sunnybrook Health Sciences Centre
-
Główny śledczy:
- Greg J Stanisz, PhD
-
Główny śledczy:
- Christopher Lim, MD
-
Główny śledczy:
- Danny Vesprini, MSc, MD
-
Główny śledczy:
- Stanley K Liu, MD, PhD
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
- Dorosły
- Starszy dorosły
Akceptuje zdrowych ochotników
Opis
Inclusion Criteria:
- PI-RADS category 3 prostate cancer with upcoming targeted biopsy
Exclusion Criteria:
- Contraindications to MRI
- Prior radiotherapy
- Prior chemotherapy
- Prior prostate biopsy
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Diagnostyczny
- Przydział: Nie dotyczy
- Model interwencyjny: Zadanie dla jednej grupy
- Maskowanie: Brak (otwarta etykieta)
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Eksperymentalny: Diagnostic Test: Saturation Transfer (ST)-MRI
Non-contrast magnetic resonance imaging "Saturation Transfer" scans consisting of magnetization transfer (MT) and chemical exchange saturation transfer (CEST)
|
Saturation transfer MRI (chemical exchange saturation transfer and magnetization transfer) used to identify two additional biopsy locations in addition to those identified by conventional MRI.
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Aiding the detection of prostate cancer
Ramy czasowe: 1 year
|
To determine whether MT/CEST MRI can aid in the detection of prostate cancer.
The histopathological detection of cancer in biopsy cores will serve as a measure of outcome to which the MT/CEST MRI parameter and relaxation images will be compared.
|
1 year
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Aiding risk stratification and the decision whether targeted prostate biopsy is justified
Ramy czasowe: 1 year
|
To determine whether MT/CEST MRI can aid multiparametric MRI (mpMRI) in risk stratification and to decide whether targeted prostate biopsy is justified.
The presence of cancer detected histopathologically in biopsy locations suggested by MT/CEST MRI, but not chosen for biopsy by convention mpMRI will serve as a measure of outcome.
|
1 year
|
Współpracownicy i badacze
Śledczy
- Główny śledczy: Greg J Stanisz, PhD, Sunnybrook Research Institute
- Główny śledczy: Christopher Lim, MD, Sunnybrook Health Sciences Centre
- Główny śledczy: Danny Vesprini, MSc, MD, Sunnybrook Health Sciences Centre
- Główny śledczy: Stanley K Liu, MD, PhD, Sunnybrook Health Sciences Centre
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Szacowany)
Zakończenie podstawowe (Szacowany)
Ukończenie studiów (Szacowany)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Inne numery identyfikacyjne badania
- 7378 (CTEP)
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .