Dynamic Management of Excess Residual Limb Pressure With New Smart Socket Technology/Intelligent Prosthetic Socket With Variable Volume and Elevated Vacuum Systems (SMARTsocket-)
Dynamic Management of Excess Residual Limb Pressure With New Smart Socket Technology/Intelligent Amputee Sockets Employing Real Time Advanced Photonic Sensors for Optimum Fit and Pressure Relief Through Active Controls/Intelligent Prosthetic Socket With Variable Volume and Elevated Vacuum Systems
This study centers around the imaging of internal structures of residual limb by means of modern radiographic imaging techniques (Dynamic Radiography-DRSA).
The purpose of our research is to further study the behavior of bones and soft tissue of the socket-stump interface during dynamic tasks such as walking or brisk walking. In the long term this research could prove a basis for improvements in the general design of sockets for the new generation of prosthetic devices.
Visão geral do estudo
Status
Condições
Intervenção / Tratamento
Descrição detalhada
There is very little known about the dynamic conditions inside a prosthetic socket, despite several research efforts based on pressure sensors, static X-ray images and/or computer simulations (FEM). The man reason is the inability of current measuring devices to track with enough resolution the in-vivo high speed kinematics of the stump-socket interface. Socket manufacturing and rectification in the field still relies on the experience and skill of the technician and feedback from the patient. This results in considerable dissatisfaction among the users and poor quantification of the socket fitting problems.
For lower extremity amputees, a well-fitting socket is an important element for a successful rehabilitation. The socket provides the interface between the prosthesis and residual limb, which is designed to provide comfort, appropriate load transmission, and efficient movement control. Attaining these objectives is extremely challenging, with up to 55% of lower limb amputees reporting dissatisfaction with socket comfort, residual limb pain, and/or skin breakdown. In addition, current techniques used to produce sockets with suitable characteristics are labor and cost intensive, and depend on the work of skilled prosthetists that are relatively scarce compared to the number of amputees. Currently, there are more than 500,000 lower limb amputees in the U.S. alone, with 60,000 new ones every year. For upper extremity amputees the issues related to the efficiency of movement, load transmission and comfort become even more challenging due to the different nature of the associated motor skills and performing tasks. Similarly there are l7,350 annual upper limb amputations distal to elbow in individuals under 21 years of age in the US. In most developed countries there are 1.55 amputees per 1000 people. Most amputees wear a prosthesis for about 70 hr/week and use crutches or wheelchairs as alternative assistive devices when performing certain tasks. Current solutions do not meet the patient specific needs.
It is suggested that our findings can further the understanding of the effects of slippage or harmful relative motion between stump and socket. Eventually new - and scientific based - guidelines for the fitting of artificial limbs could be recommended.
Tipo de estudo
Inscrição (Antecipado)
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
-
Nicosia, Chipre
- SAFE LLC
-
-
-
-
New York
-
New York, New York, Estados Unidos, 11023
- George Papaioannou Ph.d
-
-
Wisconsin
-
Milwaukee, New York, Nicosia, Wisconsin, Estados Unidos, 53211
- Safe Llc Move Center and Laboratories
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
- trans-tibial amputation, proficiency in prosthesis use
Exclusion Criteria:
- pregnancy, balance impairment, stump skin breakdown
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Ciência básica
- Alocação: N / D
- Modelo Intervencional: Atribuição de grupo único
- Mascaramento: Nenhum (rótulo aberto)
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Experimental: adaptive trans-tibial socket
subjects are fitted with experimental sockets.
|
trans tibial socket with actuator zones (inflatable fluid bladders)
Outros nomes:
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Prazo |
|---|---|
|
Change in skin/socket displacement with different prosthetic sockets
Prazo: one (1) year -baseline end of first year i.e. end of 2010 - with measurements at sixth and twelveth month
|
one (1) year -baseline end of first year i.e. end of 2010 - with measurements at sixth and twelveth month
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: George Papaioannou, Ph.D, SAVE LLC
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo
Conclusão Primária (Real)
Conclusão do estudo (Antecipado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Estimativa)
Atualizações de registro de estudo
Última Atualização Postada (Estimativa)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Outros números de identificação do estudo
- CPSHI/IRB 00002053
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .