- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT07598331
Contrast-Enhanced Ultrasound for Early Assessment of Microwave Ablation in HCC (SBS-CEUS)
A Diagnostic Pilot Study of Side-by-Side Contrast-Enhanced Ultrasound for Early Assessment of Microwave Ablation Efficacy in Hepatocellular Carcinoma
Hepatocellular carcinoma (HCC) is the sixth most common malignancy and the fourth leading cause of cancer-related deaths worldwide [1]. Although surgical resection remains the reference curative therapy, ultrasound-guided microwave ablation (MWA) yields comparable oncologic outcomes [2,3] and is endorsed as a first-line option in several national and international guidelines. A sufficient ablative ablation margins (AM) is pivotal for preventing local tumour progression (LTP) [4,5].
According to current consensus, technical success is judged one month after ablation using contrast-enhanced CT (CE-CT) or MRI (CE-MRI) together with long-term follow-up [6,7]. Yet, inflammatory changes within the ablation zone peak during the first few days, delaying reliable evaluation, increasing patient anxiety, and often necessitating multiple imaging sessions.In recent years, various fusion imaging methods have been used to assess AM after ablation in HCC patients, including CT-CT image fusion [8, 9], MR-MR image fusion [10, 11], and contrast-enhanced ultrasound (CEUS)-CT/MR image fusion [12, 13]. However, fusion imaging techniques require high-quality preoperative images, and post-operative liver displacement and deformation due to tumour removal can make image registration difficult.
Contrast-enhanced ultrasound (CEUS) is widely used in clinical practice due to its economic simplicity, lack of radiation, and ability to display lesion areas in real time [14-16]. Recently, fusion imaging based on 3D CEUS has been reported to show good accuracy in AM evaluation [17-19], but the assessment of AM for multiple ablations of multiple tumours remains uncertain.Therefore, the potential of CEUS for early assessment of AM should be further developed. Simultaneous-screen comparison contrast-enhanced ultrasound (SBS-CEUS) refers to the simultaneous comparison of arterial phase images before and after tumour ablation under the same settings of the ultrasound diagnostic instrument.Studies have shown [20] that SBS-CEUS has significant value in displaying liver lesions in difficult-to-visualise areas, but to date, no studies have systematically compared SBS-CEUS with CEUS in the assessment of AM.
This retrospective study therefore compared the diagnostic accuracy of SBS-CEUS versus CEUS for early (1-3 days) assessment of the AM after MWA in patients with HCC.
Visão geral do estudo
Status
Intervenção / Tratamento
Tipo de estudo
Inscrição (Real)
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
Jilin
-
Changchun, Jilin, China, 130021
- GE
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
- Adulto
- Adulto mais velho
Aceita Voluntários Saudáveis
Descrição
Inclusion Criteria:
a) HCC diagnosed according to EASL guidelines and confirmed by pathology and/or typical imaging features on CE-CT, CE-MRI, or CEUS;b) ≤3 lesions, each ≤5 cm, without vascular/bile-duct invasion or distant metastasis;c) CE-MRI performed at our centre ≤1 month before and ≤1 month after ablation (CE-CT for MRI-contraindicated patients) to serve as the reference standard;d)Baseline CEUS ≤7 days before MWA and follow-up CEUS 1-3 days after MWA .
Exclusion Criteria:
a) Severe comorbid disease;b) Missing mandatory imaging;c) Any condition judged by the investigators to preclude reliable data acquisition.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Triagem
- Alocação: N / D
- Modelo Intervencional: Atribuição de grupo único
- Mascaramento: Nenhum (rótulo aberto)
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Experimental: Side-by-Side Contrast-Enhanced Ultrasound for Early Assessment of Microwave Ablation Efficacy in HCC
Side-by-Side Contrast-Enhanced Ultrasound is performed 1-3 days after MWA surgery.
|
Side-by-Side Contrast-Enhanced Ultrasound is performed 1-3 days after MWA surgery, with contrast-enhanced MRI or CT one month after microwave ablation as the reference standard. Contrast-Enhanced Ultrasound is performed within 7 days before MWA surgery and 1-3 days after surgery, with contrast-enhanced MRI or CT one month after microwave ablation as the reference standard. |
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Prazo |
|---|---|
|
Side-by-Side Contrast-Enhanced Ultrasound and Contrast-Enhanced Ultrasound were used to evaluate the efficacy of microwave ablation for hepatocellular carcinoma. Based on the minimum distance between the tumour margin and the ablation zone, early postope
Prazo: Contrast-enhanced ultrasound (CEUS) was performed within 7 days prior to microwave ablation for hepatocellular carcinoma, and side-by-side contrast-enhanced ultrasound and contrast-enhanced ultrasound were performed simultaneously within 1-3 days after t
|
Contrast-enhanced ultrasound (CEUS) was performed within 7 days prior to microwave ablation for hepatocellular carcinoma, and side-by-side contrast-enhanced ultrasound and contrast-enhanced ultrasound were performed simultaneously within 1-3 days after t
|
Colaboradores e Investigadores
Patrocinador
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- 2023-KS-233
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
produto fabricado e exportado dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .
Ensaios clínicos em Carcinoma Hepatocelular (CHC)
-
Ain Shams UniversityConcluído
-
Seoul National University HospitalBayerConcluídoDiagnóstico | HccRepublica da Coréia
-
Shanghai Zhongshan HospitalAinda não está recrutandoCarcinom hepatocelular irressecável
-
Yonsei UniversityAinda não está recrutando
-
Fondazione IRCCS Policlinico San Matteo di PaviaConcluídoCarcinoma Hepatocelular (CHC) | Masld-hcc | Hcv_hccItália
-
Assistance Publique - Hôpitaux de ParisAinda não está recrutandoCarcinoma hepatocelular avançado (HCC), classificado como BCLC estágio B ou C, tratado com uma combinação de terapia de radiação interna seletivaFrança
-
Jiangsu HengRui Medicine Co., Ltd.ConcluídoTerapia adjuvante em pacientes com carcinoma hepatocelular (HCC) com alto risco de recorrência após ressecção ou ablação curativaChina