- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT07598331
Contrast-Enhanced Ultrasound for Early Assessment of Microwave Ablation in HCC (SBS-CEUS)
A Diagnostic Pilot Study of Side-by-Side Contrast-Enhanced Ultrasound for Early Assessment of Microwave Ablation Efficacy in Hepatocellular Carcinoma
Hepatocellular carcinoma (HCC) is the sixth most common malignancy and the fourth leading cause of cancer-related deaths worldwide [1]. Although surgical resection remains the reference curative therapy, ultrasound-guided microwave ablation (MWA) yields comparable oncologic outcomes [2,3] and is endorsed as a first-line option in several national and international guidelines. A sufficient ablative ablation margins (AM) is pivotal for preventing local tumour progression (LTP) [4,5].
According to current consensus, technical success is judged one month after ablation using contrast-enhanced CT (CE-CT) or MRI (CE-MRI) together with long-term follow-up [6,7]. Yet, inflammatory changes within the ablation zone peak during the first few days, delaying reliable evaluation, increasing patient anxiety, and often necessitating multiple imaging sessions.In recent years, various fusion imaging methods have been used to assess AM after ablation in HCC patients, including CT-CT image fusion [8, 9], MR-MR image fusion [10, 11], and contrast-enhanced ultrasound (CEUS)-CT/MR image fusion [12, 13]. However, fusion imaging techniques require high-quality preoperative images, and post-operative liver displacement and deformation due to tumour removal can make image registration difficult.
Contrast-enhanced ultrasound (CEUS) is widely used in clinical practice due to its economic simplicity, lack of radiation, and ability to display lesion areas in real time [14-16]. Recently, fusion imaging based on 3D CEUS has been reported to show good accuracy in AM evaluation [17-19], but the assessment of AM for multiple ablations of multiple tumours remains uncertain.Therefore, the potential of CEUS for early assessment of AM should be further developed. Simultaneous-screen comparison contrast-enhanced ultrasound (SBS-CEUS) refers to the simultaneous comparison of arterial phase images before and after tumour ablation under the same settings of the ultrasound diagnostic instrument.Studies have shown [20] that SBS-CEUS has significant value in displaying liver lesions in difficult-to-visualise areas, but to date, no studies have systematically compared SBS-CEUS with CEUS in the assessment of AM.
This retrospective study therefore compared the diagnostic accuracy of SBS-CEUS versus CEUS for early (1-3 days) assessment of the AM after MWA in patients with HCC.
Panoramica dello studio
Stato
Intervento / Trattamento
Tipo di studio
Iscrizione (Effettivo)
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
Jilin
-
Changchun, Jilin, Cina, 130021
- GE
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
- Adulto
- Adulto più anziano
Accetta volontari sani
Descrizione
Inclusion Criteria:
a) HCC diagnosed according to EASL guidelines and confirmed by pathology and/or typical imaging features on CE-CT, CE-MRI, or CEUS;b) ≤3 lesions, each ≤5 cm, without vascular/bile-duct invasion or distant metastasis;c) CE-MRI performed at our centre ≤1 month before and ≤1 month after ablation (CE-CT for MRI-contraindicated patients) to serve as the reference standard;d)Baseline CEUS ≤7 days before MWA and follow-up CEUS 1-3 days after MWA .
Exclusion Criteria:
a) Severe comorbid disease;b) Missing mandatory imaging;c) Any condition judged by the investigators to preclude reliable data acquisition.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Selezione
- Assegnazione: N / A
- Modello interventistico: Assegnazione di gruppo singolo
- Mascheramento: Nessuno (etichetta aperta)
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Sperimentale: Side-by-Side Contrast-Enhanced Ultrasound for Early Assessment of Microwave Ablation Efficacy in HCC
Side-by-Side Contrast-Enhanced Ultrasound is performed 1-3 days after MWA surgery.
|
Side-by-Side Contrast-Enhanced Ultrasound is performed 1-3 days after MWA surgery, with contrast-enhanced MRI or CT one month after microwave ablation as the reference standard. Contrast-Enhanced Ultrasound is performed within 7 days before MWA surgery and 1-3 days after surgery, with contrast-enhanced MRI or CT one month after microwave ablation as the reference standard. |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Lasso di tempo |
|---|---|
|
Side-by-Side Contrast-Enhanced Ultrasound and Contrast-Enhanced Ultrasound were used to evaluate the efficacy of microwave ablation for hepatocellular carcinoma. Based on the minimum distance between the tumour margin and the ablation zone, early postope
Lasso di tempo: Contrast-enhanced ultrasound (CEUS) was performed within 7 days prior to microwave ablation for hepatocellular carcinoma, and side-by-side contrast-enhanced ultrasound and contrast-enhanced ultrasound were performed simultaneously within 1-3 days after t
|
Contrast-enhanced ultrasound (CEUS) was performed within 7 days prior to microwave ablation for hepatocellular carcinoma, and side-by-side contrast-enhanced ultrasound and contrast-enhanced ultrasound were performed simultaneously within 1-3 days after t
|
Collaboratori e investigatori
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- 2023-KS-233
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
prodotto fabbricato ed esportato dagli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .
Prove cliniche su Carcinoma epatocellulare (HCC)
-
Shanghai Zhongshan HospitalNon ancora reclutamentoCarcinom epatocellulare non resecabile
-
Guangzhou Virotech Pharmaceutical Co., Ltd.Reclutamento
-
Tongji HospitalNon ancora reclutamento
-
Qianfoshan HospitalNon ancora reclutamento
-
University of PisaAzienda Ospedaliera Città della Salute e della Scienza di Torino; Fondazione... e altri collaboratoriReclutamento
-
Seoul National University HospitalPhilips HealthcareCompletato
-
Huazhong University of Science and TechnologySconosciuto
-
Taipei Medical University WanFang HospitalTerminato
-
Leiden University Medical CenterMedtronic; ZonMw: The Netherlands Organisation for Health Research and Development e altri collaboratoriCompletato
-
Lei ZHAONon ancora reclutamento
Prove cliniche su Side-by-Side Contrast-Enhanced Ultrasound
-
Soon Chun Hyang UniversityCompletatoTumore di KlatskinCorea, Repubblica di