- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT07625566
Anodal tDCS Over Left PPC Enhances Visuospatial Attention and Alpha Power Among Young Adults
Background: Visuospatial attention enables individuals to detect and process relevant stimuli efficiently. The posterior parietal cortex (PPC), a core hub of the dorsal attention network, exerts top-down control over visual scanning and is closely linked to alpha-band oscillations (8-13 Hz), which index attentional allocation and inhibition of distractors. Transcranial direct current stimulation (tDCS) offers a noninvasive method to alter cortical excitability transiently, but evidence for its effects on PPC-mediated attention and alpha power remains mixed.
Objective: This randomized, single-blind trial examined whether anodal tDCS over the left PPC modulates visuospatial attention and resting-state alpha power in young adults, and whether EEG changes predict behavioral performance.
Method: Thirty-two healthy participants (18-40 years) were randomized to anodal (2 mA, 20 min; n=15) or sham (n=17) stimulation. Cancellation Test performance and resting-state EEG were assessed pre- and post-stimulation. EEG analyses focused on artifact-free alpha power; regression models probed associations between neural and behavioral changes.
Visão geral do estudo
Status
Condições
Intervenção / Tratamento
Tipo de estudo
Inscrição (Real)
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
İ̇stanbul
-
Beykoz, İ̇stanbul, Turquia (Türkiye), 34820
- Istanbul Medipol University
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
- Adulto
Aceita Voluntários Saudáveis
Descrição
Inclusion Criteria:
- Age between 18 and 40 years
- Score of 21 or higher on the Montreal Cognitive Assessment Scale (MoCA)
Exclusion Criteria:
- History of neurological or psychiatric illness
- Uncorrected visual impairments
- MoCA score of 21 or lower
- Use of medications affecting cortical excitability
- History of seizures or epilepsy
- Presence of intracranial metal objects, implanted stimulating devices, or pacemakers
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Ciência básica
- Alocação: Randomizado
- Modelo Intervencional: Atribuição Paralela
- Mascaramento: Solteiro
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Experimental: Anodal tDCS Group
|
Anodal tDCS Protocol: In the Anodal tDCS participant group, a direct current of 2 mA was applied for 20 minutes in accordance with the safety guidelines.
To provide cortical stimulation, the superficial anodal electrode of the device was placed on the P3 region (left PPC), which is located in the left superior parietal lobe, corresponds to Brodmann area (BA) 40, and is associated with the dorsal visual pathway according to the international 10-20 EEG system.
The reference electrode was placed on the contralateral (opposite) shoulder.
|
|
Comparador Falso: Sham tDCS Group
|
Sham tDCS Protocol: The anode superficial electrode of the device was placed on the P3 region (left PPC), located in the left superior parietal lobe, corresponding to Brodmann area (BA) 40, and associated with the dorsal visual pathway according to the international 10-20 EEG system.
The reference electrode was placed on the contralateral (opposite) shoulder.
In the Sham tDCS group, a single 20-minute sham session was administered over the left posterior parietal cortex (P3) without delivering current, in accordance with the safety guidelines.
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
EEG recording and power in alpha band
Prazo: Before and immediately after applying tDCS
|
EEG recordings were acquired in a semi-dark, electrically shielded Faraday room using a BrainAmp 32-Channel DC System (Brain Products, Munich, Germany).
Signals were sampled at 500 Hz with a 0.01-250 Hz bandpass filter and recorded using BrainVision Recorder software.
A 32-channel Ag/AgCl electrode cap (Easycap) was positioned according to the international 10-20 system.
Resting-state EEG data were collected for 4 minutes with eyes open and 4 minutes with eyes closed.
Numerical evaluation of artifact-free EEG data for power density calculation is performed using Fast Fourier Transform (FFT) with 0.5 Hz frequency resolution, and alpha (8-13 Hz) bands were calculated and then averaged over these power spectrum values.
The amplitude values, measured from peak to peak, were recorded for each individual, and the necessary data for statistical analysis were collected.
|
Before and immediately after applying tDCS
|
|
Cancellation Test
Prazo: Before and immediately after applying tDCS
|
The Cancellation Test is one of the most widely used tools for assessing visuospatial attention.
IT consists of four subtests arranged on A4-sized sheets.
Each subtest includes 60 target stimuli distributed among 300 total stimuli.
For each subtest, separate scores are calculated for the right and left sides, including the number of correctly marked targets (IT1), omitted targets (IT2), incorrectly marked letters/shapes (IT3), total error score (IT4), and scanning time (IT5).
The total error score is calculated as the sum of omitted targets and incorrectly marked letters/shapes.
Achieving a high score (i.e., a high number of correctly marked targets and a low number of errors) and a short completion time (time score) indicate better performance.
İn the present study, the paper-and-pencil version of the Cancellation Test was chosen to reliably assess visuospatial attention and subtle tDCS-induced changes.
|
Before and immediately after applying tDCS
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Diretor de estudo: Lütfü Hanoğlu, Professor, Medipol University
- Cadeira de estudo: Mevhibe Sarıcaoğlu, PhD, Medipol University
- Diretor de estudo: Miray Budak, PhD, Rutgers University-Newark
- Cadeira de estudo: Fatma Aydın, MsC, Medipol University
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- E-10840098-772.02-605
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .