Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Outcomes of Macular Hole Surgery With Inverted Flap With vs Without Post op Posturing With SF6 in Macular Hole More Than 400 Micrometres

5 de setembro de 2026 atualizado por: Muhammad Irfan Jamil, Lahore General Hospital

This study evaluated the outcomes of surgery for large full-thickness macular holes measuring more than 400 micrometres using the inverted internal limiting membrane flap technique with sulphur hexafluoride (SF6) gas tamponade. The study was conducted at the Department of Ophthalmology, Lahore General Hospital, Lahore. A total of 52 male and female patients aged 52-84 years with full-thickness macular holes were included.

All patients underwent 23-gauge pars plana vitrectomy with hyaloidectomy and inverted internal limiting membrane flap surgery after staining with 0.05% Brilliant Blue. Patients were divided into two groups according to postoperative positioning. One group performed postoperative face-down posturing, whereas the other group did not perform face-down posturing. The study examined whether successful closure of large macular holes could be achieved without postoperative face-down positioning after surgery with SF6 gas tamponade.

Patients were followed on postoperative days 1, 7, 30, and 90. The main outcome was anatomical closure of the macular hole, which was assessed using optical coherence tomography (OCT). Successful treatment was defined as complete anatomical closure of the macular hole. The outcomes of patients who performed face-down posturing were compared with those who did not perform postoperative posturing to determine whether face-down positioning was necessary following surgery for macular holes larger than 400 micrometres.

Visão geral do estudo

Tipo de estudo

Intervencional

Inscrição (Real)

52

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

    • Punjab Province
      • Lahore, Punjab Province, Paquistão, 54000
        • Lahore General Hospital, Lahore

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Adulto
  • Adulto mais velho

Aceita Voluntários Saudáveis

Não

Descrição

Inclusion Criteria:

  • Gender: male and female
  • All patient having age between 52-84 years
  • All the patients with full thickness macular hole
  • All the patients with written informed consent

Exclusion Criteria:

  • Patients with high myopia.
  • Patient having age related macular degenerations (AMD).
  • Patient having any chorioretinal disease or Diabetic retinopathy.
  • Secondary MH causes

    • Trauma.
    • Uveitis.
    • Cystic macular edema.
    • Age-related macular degeneration
    • Glaucoma or ocular hypertension
    • corneal opacity
  • Patient with history of previously intraocular or vitrectomy surgery other than uncomplicated cataract surgery.
  • Patient with history of previous laser photocoagulation.
  • Presence of traction on the macula (OCT).
  • Patient with significant media opacity preventing retinal view or poor image quality.

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Tratamento
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição Paralela
  • Mascaramento: Nenhum (rótulo aberto)

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: Face-Down Posturing Group
Patients underwent 23-gauge pars plana vitrectomy with hyaloidectomy and inverted internal limiting membrane flap surgery after staining with 0.05% Brilliant Blue, followed by SF6 gas tamponade. After surgery, patients performed postoperative face-down posturing.
Patients underwent 23-gauge pars plana vitrectomy with hyaloidectomy and inverted internal limiting membrane flap surgery with SF6 gas tamponade.
Patients performed face-down posturing after surgery according to the postoperative instructions.
Comparador Ativo: No Face-Down Posturing Group
Patients underwent the same 23-gauge pars plana vitrectomy with hyaloidectomy and inverted internal limiting membrane flap surgery after staining with 0.05% Brilliant Blue, followed by SF6 gas tamponade. Patients did not perform postoperative face-down posturing.
Patients underwent 23-gauge pars plana vitrectomy with hyaloidectomy and inverted internal limiting membrane flap surgery with SF6 gas tamponade.
Patients were managed without postoperative face-down posturing.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Anatomical Closure of the Macular Hole on OCT
Prazo: 3 months after surgery.
Proportion of participants with complete anatomical closure of the macular hole on optical coherence tomography.
3 months after surgery.

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Investigadores

  • Investigador principal: Ahmad Fauzan, Lahore General Hospital, Lahore

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

1 de maio de 2026

Conclusão Primária (Estimado)

30 de outubro de 2026

Conclusão do estudo (Estimado)

30 de outubro de 2026

Datas de inscrição no estudo

Enviado pela primeira vez

22 de agosto de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

22 de agosto de 2026

Primeira postagem (Real)

26 de agosto de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

10 de setembro de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

5 de setembro de 2026

Última verificação

1 de setembro de 2026

Mais Informações

Termos relacionados a este estudo

Outros números de identificação do estudo

  • LahoreGeneralH19

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever