Irreversible Electroporation for Treatment of Solid Abdominal Tumors
Irreversible electroporation (IRE) is a novel non-thermal ablation modality with promise for revolutionizing the treatment for local solid tumors.
With the growing demand for alternative and less invasive treatments for localized tumors, the investigators have seen the development and investigation of several tissue ablation modalities, including radiofrequency ablation (RFA), microwave ablation, and cryoablation. Although these modalities have been efficacious, they have some disadvantages owing to their reliance on thermal energy for creating cell death.
Обзор исследования
Подробное описание
Irreversible electroporation is novel in that it does not use thermal energy, but electrical energy to produce focused cell death while sparing the normal extracellular matrix, nearby vessels, and structures, while allowing for rapid normal tissue regrowth.
Unlike thermal ablation modalities, Irreversible electroporation does not require significant consideration for dissipation of thermal energy, or heat sink, and has less complications relating to damage of normal soft tissue, eliminating a major cause of treatment failure.
Irreversible electroporation is a novel minimally invasive tumor/tissue ablation technique that can be used under guidance of ultrasound (US) or computed tomography (CT), without inducing thermal damaging effects, and with preservation of the surrounding vital structures such as vessels, bile ducts, urethra, and nerves which remain intact to function normally, even in locally advanced tumors. The technique depends upon inducing apoptotic non-necrotic cell death in short procedure time.
It has the advantage of allowing quick tissue regeneration. Irreversible electroporation treatment time is significantly shorter than traditional thermal ablation modalities, usually in few minutes range, and allows for treating considerably larger lesions than thermal ablation modalities.
Тип исследования
Регистрация (Ожидаемый)
Фаза
- Непригодный
Контакты и местонахождение
Критерии участия
Критерии приемлемости
Возраст, подходящий для обучения
- Ребенок
- Взрослый
- Пожилой взрослый
Принимает здоровых добровольцев
Полы, имеющие право на обучение
Описание
Inclusion Criteria:
- Patients with unresectable solid abdominal tumors (hepatic, pancreatic, porta hepatis,…).
- The mass measures less than 4 cm.
- Associated with no or oligo metastatic lesions
Exclusion Criteria:
- Patients with cardiac arrhythmia and pacemaker.
- Patients unfit for general anesthesia.
- The lesion size is larger than 4 cm.
Учебный план
Как устроено исследование?
Детали дизайна
- Основная цель: Уход
- Распределение: Н/Д
- Интервенционная модель: Одногрупповое задание
- Маскировка: Нет (открытая этикетка)
Оружие и интервенции
Группа участников / Армия |
Вмешательство/лечение |
|---|---|
|
Другой: hepatic focal lesions and pancreatic masses
|
minimal invasive ablative technique for tumors
|
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
The ablation success
Временное ограничение: 3 months
|
the ability to deliver planned therapy and to have no residual
|
3 months
|
Вторичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Local recurrence
Временное ограничение: 3,6 and 12 months
|
defined as re appearance of viable tumor after period during which no tumor could be detected
|
3,6 and 12 months
|
Соавторы и исследователи
Спонсор
Публикации и полезные ссылки
Общие публикации
- Davalos RV, Mir IL, Rubinsky B. Tissue ablation with irreversible electroporation. Ann Biomed Eng. 2005 Feb;33(2):223-31. doi: 10.1007/s10439-005-8981-8.
- Edd JF, Horowitz L, Davalos RV, Mir LM, Rubinsky B. In vivo results of a new focal tissue ablation technique: irreversible electroporation. IEEE Trans Biomed Eng. 2006 Jul;53(7):1409-15. doi: 10.1109/TBME.2006.873745.
- Lee EW, Chen C, Prieto VE, Dry SM, Loh CT, Kee ST. Advanced hepatic ablation technique for creating complete cell death: irreversible electroporation. Radiology. 2010 May;255(2):426-33. doi: 10.1148/radiol.10090337.
- Rubinsky B. Irreversible electroporation in medicine. Technol Cancer Res Treat. 2007 Aug;6(4):255-60. doi: 10.1177/153303460700600401.
- Kasivisvanathan V, Thapar A, Oskrochi Y, Picard J, Leen EL. Irreversible electroporation for focal ablation at the porta hepatis. Cardiovasc Intervent Radiol. 2012 Dec;35(6):1531-4. doi: 10.1007/s00270-012-0363-7. Epub 2012 Feb 25.
- Usman M, Moore W, Talati R, Watkins K, Bilfinger TV. Irreversible electroporation of lung neoplasm: a case series. Med Sci Monit. 2012 Jun;18(6):CS43-7. doi: 10.12659/msm.882888.
- Esser AT, Smith KC, Gowrishankar TR, Weaver JC. Towards solid tumor treatment by nanosecond pulsed electric fields. Technol Cancer Res Treat. 2009 Aug;8(4):289-306. doi: 10.1177/153303460900800406.
- Silk MT, Wimmer T, Lee KS, Srimathveeravalli G, Brown KT, Kingham PT, Fong Y, Durack JC, Sofocleous CT, Solomon SB. Percutaneous ablation of peribiliary tumors with irreversible electroporation. J Vasc Interv Radiol. 2014 Jan;25(1):112-8. doi: 10.1016/j.jvir.2013.10.012. Epub 2013 Nov 18.
Даты записи исследования
Изучение основных дат
Начало исследования (Ожидаемый)
Первичное завершение (Ожидаемый)
Завершение исследования (Ожидаемый)
Даты регистрации исследования
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Действительный)
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Дополнительные соответствующие термины MeSH
Другие идентификационные номера исследования
- IREAT
Информация о лекарствах и устройствах, исследовательские документы
Изучает лекарственный продукт, регулируемый FDA США.
Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.
продукт, произведенный в США и экспортированный из США.
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .
Клинические исследования Irreversible electroporation
-
Arga Medtech SAРекрутингМерцательная аритмия (ФП) | Пароксизмальная ФП | Стойкая мерцательная аритмияСоединенные Штаты, Нидерланды, Хорватия, Бельгия, Литва, Чехия