Эта страница была переведена автоматически, точность перевода не гарантируется. Пожалуйста, обратитесь к английской версии для исходного текста.

Radiological Comparison Between Single-Leg and Double-Leg Stance in the Assessment of Genu Varum: Pre- and Postoperative Evaluation and Functional Outcomes

18 июля 2026 г. обновлено: Ahmed Salah, Assiut University

Genu varum, commonly known as bow-legged deformity, is characterized by an outward angulation of the knee joint that disrupts normal lower limb alignment and weight distribution(1,2). This condition alters the mechanical axis of the limb, often increasing medial compartment loading, which can accelerate degenerative joint changes and pain. Radiographic assessment plays a central role in quantifying the deformity, typically measured through parameters such as the hip-knee-ankle (HKA) angle, mechanical axis deviation (MAD), and medial proximal tibial angle (MPTA)(1,2).

Weight-bearing posture during imaging significantly influences these alignment parameters. Several studies have demonstrated that single-leg stance radiographs produce more physiologically representative alignment measurements than double-leg stance, since the single-leg condition better simulates natural load distribution and joint reaction forces during locomotion(3,4). The single-leg stance increases joint compression and reveals hidden malalignments that may be masked in double-leg or non-weight-bearing positions. Consequently, preoperative evaluations based solely on double-leg stance may underestimate the severity of genu varum deformity(3,4).

Surgical correction, through techniques such as high tibial osteotomy or guided growth, aims to restore the mechanical axis to a near-neutral position, improving load symmetry and delaying degenerative changes(4,5). Postoperative evaluation is essential for monitoring realignment success and predicting functional recovery, which often involves comparing radiological correction with clinical outcomes such as range of motion, pain reduction, and activity resumption. However, the correspondence between radiographic correction measured under different stance conditions and postoperative function remains poorly defined(6,7).

Recent evidence suggests that patients assessed preoperatively under single-leg stance conditions may have more accurate predictions of postoperative alignment and function than those evaluated under double-leg stance (5,6). Furthermore, differences between stance types may influence surgical planning decisions, including the degree of correction targeted and the fixation technique used. Functional outcomes after genu varum correction depend not only on bony realignment but also on balanced muscular forces, proprioception, and joint stability - factors more dynamically engaged in single-leg stance evaluation(7,8).

Despite increasing recognition of weight-bearing differences in radiological evaluation, limited research directly compares single-leg versus double-leg stance assessment for genu varum across preoperative and postoperative stages. Establishing which stance provides a more reliable correlation with functional outcomes could refine surgical planning, enhance rehabilitation monitoring, and standardize postoperative evaluation protocols for improved patient outcomes.

Обзор исследования

Статус

Еще не набирают

Условия

Тип исследования

Наблюдательный

Регистрация (Оцененный)

70

Критерии участия

Исследователи ищут людей, которые соответствуют определенному описанию, называемому критериям приемлемости. Некоторыми примерами этих критериев являются общее состояние здоровья человека или предшествующее лечение.

Критерии приемлемости

Возраст, подходящий для обучения

  • Взрослый
  • Пожилой взрослый

Принимает здоровых добровольцев

Нет

Метод выборки

Вероятностная выборка

Исследуемая популяция

Patients with genu varum

Описание

Inclusion Criteria:

  • • Patients aged 18-65 years diagnosed with genu varum requiring surgical correction (e.g., high tibial osteotomy )

    • Willingness to participate and provide informed consent.
    • Ability to stand independently for radiographic assessment.
    • No prior lower limb surgery within the last year.

Exclusion Criteria:

  • Patients with genu varum with Blount's disease, rickets and metabolic bone disease.

    • History of knee surgery within the last year.
    • Neurological, psychological, or systemic disorders affecting gait or stance.
    • Inadequate preoperative or follow-up radiographs.
    • Inability to comply with follow-up schedule.

Учебный план

В этом разделе представлена ​​подробная информация о плане исследования, в том числе о том, как планируется исследование и что оно измеряет.

Как устроено исследование?

Детали дизайна

Когорты и вмешательства

Группа / когорта
Group A
single-leg stance group
Group B
double-leg stance group

Что измеряет исследование?

Первичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
radiographic alignment parameters
Временное ограничение: 3 months postoperative
Difference in radiographic alignment parameters between single-leg and double-leg stance pre- and postoperatively.
3 months postoperative

Соавторы и исследователи

Здесь вы найдете людей и организации, участвующие в этом исследовании.

Спонсор

Даты записи исследования

Эти даты отслеживают ход отправки отчетов об исследованиях и сводных результатов на сайт ClinicalTrials.gov. Записи исследований и сообщаемые результаты проверяются Национальной медицинской библиотекой (NLM), чтобы убедиться, что они соответствуют определенным стандартам контроля качества, прежде чем публиковать их на общедоступном веб-сайте.

Изучение основных дат

Начало исследования (Оцененный)

1 июня 2026 г.

Первичное завершение (Оцененный)

1 июня 2027 г.

Завершение исследования (Оцененный)

1 декабря 2027 г.

Даты регистрации исследования

Первый отправленный

5 мая 2026 г.

Впервые представлено, что соответствует критериям контроля качества

18 июля 2026 г.

Первый опубликованный (Действительный)

22 июля 2026 г.

Обновления учебных записей

Последнее опубликованное обновление (Действительный)

22 июля 2026 г.

Последнее отправленное обновление, отвечающее критериям контроля качества

18 июля 2026 г.

Последняя проверка

1 июля 2026 г.

Дополнительная информация

Термины, связанные с этим исследованием

Другие идентификационные номера исследования

  • RadiologicalSingle Double leg

Информация о лекарствах и устройствах, исследовательские документы

Изучает лекарственный продукт, регулируемый FDA США.

Нет

Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.

Нет

Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .

Подписаться