- ICH GCP
- Amerikanska kliniska prövningsregistret
- Klinisk prövning NCT07605793
Reliability and Validity of Physical Performance Tests in Individuals With Obesity
Clinician-Friendly Physical Performance Tests in Individuals With Obesity: Reliability and Validity
This study aims to investigate the reliability and validity of practical performance-based physical function tests in individuals with obesity. Functional limitations such as reduced walking ability, impaired balance, and decreased lower extremity strength are common in people with obesity and may negatively affect daily activities and quality of life.
Participants will complete several commonly used clinical functional tests, including the 1-Minute Stair Climbing Test, 40-Meter Fast-Paced Walk Test, 2-Minute Walk Test, Timed Up and Go Test, and 30-Second Sit-to-Stand Test. In addition, cardiopulmonary exercise testing, balance assessment, and knee extensor muscle strength measurements will be performed.
The study will evaluate whether these simple and clinically applicable tests provide reliable results over repeated measurements and whether they are associated with objective indicators of physical function such as maximal oxygen consumption (VO₂max), balance performance, and muscle strength. The findings may help clinicians use practical and cost-effective tools to assess physical function in individuals with obesity.
Studieöversikt
Status
Betingelser
Intervention / Behandling
Studietyp
Inskrivning (Beräknad)
Deltagandekriterier
Urvalskriterier
Åldrar som är berättigade till studier
- Vuxen
- Äldre vuxen
Tar emot friska volontärer
Testmetod
Studera befolkning
Beskrivning
Inclusion Criteria:
- Body mass index (BMI) ≥ 30 kg/m²
- Stable body weight during the last 3 months (less than ±2 kg change)
- Ability to perform daily living activities independently
Exclusion Criteria:
- History of cardiovascular disease
- History of pulmonary disease
- History of neurological disease
- Musculoskeletal injury affecting lower extremity function
- Presence of lower extremity prosthesis or severe deformity
- Major surgery within the previous 6 months
- Pregnancy
- Postpartum period
- Vestibular disorders affecting balance
- Visual impairments affecting test performance
- Hearing impairments affecting test performance
- Cognitive impairment limiting understanding of instructions
- Participation in strenuous physical activity before testing
- Use of medications affecting cardiopulmonary responses (e.g., beta-blockers)
Studieplan
Hur är studien utformad?
Designdetaljer
Vad mäter studien?
Primära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
|---|---|---|
|
1-Minute Stair Climbing Test
Tidsram: 1 hour
|
A performance-based functional test used to assess stair climbing ability and lower extremity functional capacity.
The total number of completed stair cycles within 1 minute will be recorded.
|
1 hour
|
|
40-Meter Fast-Paced Walk Test
Tidsram: 1 hour
|
A walking performance test used to evaluate fast-paced gait speed and functional mobility.
The time required to complete a total walking distance of 40 meters will be measured in seconds.
|
1 hour
|
|
2-Minute Walk Test
Tidsram: 1 hour
|
A functional endurance test used to assess ambulatory capacity.
The total walking distance completed within 2 minutes will be recorded in meters.
|
1 hour
|
|
Timed Up and Go Test
Tidsram: 1 hour
|
A functional mobility test used to assess dynamic balance and independent mobility.
The time required to stand up from a chair, walk 3 meters, return, and sit down will be measured in seconds.
|
1 hour
|
|
30-Second Sit-to-Stand Test
Tidsram: 1 hour
|
A lower extremity functional strength and endurance test.
The total number of sit-to-stand repetitions completed within 30 seconds will be recorded.
|
1 hour
|
Sekundära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
|---|---|---|
|
Cardiopulmonary Exercise Testing (VO₂max)
Tidsram: 1 hour
|
A maximal exercise test performed using the Modified Bruce Protocol on a treadmill to assess aerobic exercise capacity.
Maximal oxygen consumption (VO₂max) values will be recorded.
|
1 hour
|
|
Static Balance Assessment
Tidsram: 1 hour
|
Balance performance will be evaluated using the PROKIN® computerized balance assessment system.
Parameters related to postural stability and body sway during static tasks will be recorded
|
1 hour
|
|
Knee Extensor Muscle Strength
Tidsram: 1 hour
|
Isometric knee extensor muscle strength will be measured using a hand-held dynamometer.
Maximum voluntary contraction force will be recorded.
|
1 hour
|
|
Dynamic Balance Assessment
Tidsram: 1 hour
|
Description: Balance performance will be evaluated using the PROKIN® computerized balance assessment system.
Parameters related to postural stability and body sway during static and dynamic tasks will be recorded
|
1 hour
|
Samarbetspartners och utredare
Sponsor
Studieavstämningsdatum
Studera stora datum
Studiestart (Beräknad)
Primärt slutförande (Beräknad)
Avslutad studie (Beräknad)
Studieregistreringsdatum
Först inskickad
Först inskickad som uppfyllde QC-kriterierna
Första postat (Faktisk)
Uppdateringar av studier
Senaste uppdatering publicerad (Faktisk)
Senaste inskickade uppdateringen som uppfyllde QC-kriterierna
Senast verifierad
Mer information
Termer relaterade till denna studie
Nyckelord
Ytterligare relevanta MeSH-villkor
Andra studie-ID-nummer
- 21
Läkemedels- och apparatinformation, studiedokument
Studerar en amerikansk FDA-reglerad läkemedelsprodukt
Studerar en amerikansk FDA-reglerad produktprodukt
Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .