- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT07605793
Reliability and Validity of Physical Performance Tests in Individuals With Obesity
Clinician-Friendly Physical Performance Tests in Individuals With Obesity: Reliability and Validity
This study aims to investigate the reliability and validity of practical performance-based physical function tests in individuals with obesity. Functional limitations such as reduced walking ability, impaired balance, and decreased lower extremity strength are common in people with obesity and may negatively affect daily activities and quality of life.
Participants will complete several commonly used clinical functional tests, including the 1-Minute Stair Climbing Test, 40-Meter Fast-Paced Walk Test, 2-Minute Walk Test, Timed Up and Go Test, and 30-Second Sit-to-Stand Test. In addition, cardiopulmonary exercise testing, balance assessment, and knee extensor muscle strength measurements will be performed.
The study will evaluate whether these simple and clinically applicable tests provide reliable results over repeated measurements and whether they are associated with objective indicators of physical function such as maximal oxygen consumption (VO₂max), balance performance, and muscle strength. The findings may help clinicians use practical and cost-effective tools to assess physical function in individuals with obesity.
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Tipo di studio
Iscrizione (Stimato)
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
- Adulto
- Adulto più anziano
Accetta volontari sani
Metodo di campionamento
Popolazione di studio
Descrizione
Inclusion Criteria:
- Body mass index (BMI) ≥ 30 kg/m²
- Stable body weight during the last 3 months (less than ±2 kg change)
- Ability to perform daily living activities independently
Exclusion Criteria:
- History of cardiovascular disease
- History of pulmonary disease
- History of neurological disease
- Musculoskeletal injury affecting lower extremity function
- Presence of lower extremity prosthesis or severe deformity
- Major surgery within the previous 6 months
- Pregnancy
- Postpartum period
- Vestibular disorders affecting balance
- Visual impairments affecting test performance
- Hearing impairments affecting test performance
- Cognitive impairment limiting understanding of instructions
- Participation in strenuous physical activity before testing
- Use of medications affecting cardiopulmonary responses (e.g., beta-blockers)
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
1-Minute Stair Climbing Test
Lasso di tempo: 1 hour
|
A performance-based functional test used to assess stair climbing ability and lower extremity functional capacity.
The total number of completed stair cycles within 1 minute will be recorded.
|
1 hour
|
|
40-Meter Fast-Paced Walk Test
Lasso di tempo: 1 hour
|
A walking performance test used to evaluate fast-paced gait speed and functional mobility.
The time required to complete a total walking distance of 40 meters will be measured in seconds.
|
1 hour
|
|
2-Minute Walk Test
Lasso di tempo: 1 hour
|
A functional endurance test used to assess ambulatory capacity.
The total walking distance completed within 2 minutes will be recorded in meters.
|
1 hour
|
|
Timed Up and Go Test
Lasso di tempo: 1 hour
|
A functional mobility test used to assess dynamic balance and independent mobility.
The time required to stand up from a chair, walk 3 meters, return, and sit down will be measured in seconds.
|
1 hour
|
|
30-Second Sit-to-Stand Test
Lasso di tempo: 1 hour
|
A lower extremity functional strength and endurance test.
The total number of sit-to-stand repetitions completed within 30 seconds will be recorded.
|
1 hour
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Cardiopulmonary Exercise Testing (VO₂max)
Lasso di tempo: 1 hour
|
A maximal exercise test performed using the Modified Bruce Protocol on a treadmill to assess aerobic exercise capacity.
Maximal oxygen consumption (VO₂max) values will be recorded.
|
1 hour
|
|
Static Balance Assessment
Lasso di tempo: 1 hour
|
Balance performance will be evaluated using the PROKIN® computerized balance assessment system.
Parameters related to postural stability and body sway during static tasks will be recorded
|
1 hour
|
|
Knee Extensor Muscle Strength
Lasso di tempo: 1 hour
|
Isometric knee extensor muscle strength will be measured using a hand-held dynamometer.
Maximum voluntary contraction force will be recorded.
|
1 hour
|
|
Dynamic Balance Assessment
Lasso di tempo: 1 hour
|
Description: Balance performance will be evaluated using the PROKIN® computerized balance assessment system.
Parameters related to postural stability and body sway during static and dynamic tasks will be recorded
|
1 hour
|
Collaboratori e investigatori
Sponsor
Studiare le date dei record
Studia le date principali
Inizio studio (Stimato)
Completamento primario (Stimato)
Completamento dello studio (Stimato)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- 21
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .
Prove cliniche su Physical Performance Tests
-
Rabin Medical CenterTerminatoDiabete di tipo 1Israele
-
Istanbul Kültür UniversityMarmara University; Istanbul University - Cerrahpasa (IUC)CompletatoAttività fisica | Morbo di Parkinson | Bilancia | Cadente | KinesiofobiaTacchino
-
Muş Alparlan UniversityHacettepe UniversityReclutamentoDistrofia muscolare di DuchenneTacchino
-
Dr. Mohammad Auais, PhDReclutamentoFratture dell'ancaCanada
-
University of BariProf. Maria GranoCompletato
-
Universiteit AntwerpenUniversity Hospital, Antwerp; Cliniques universitaires Saint-Luc- Université...CompletatoEmofilia A | Emofilia BBelgio