- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT07605793
Reliability and Validity of Physical Performance Tests in Individuals With Obesity
Clinician-Friendly Physical Performance Tests in Individuals With Obesity: Reliability and Validity
This study aims to investigate the reliability and validity of practical performance-based physical function tests in individuals with obesity. Functional limitations such as reduced walking ability, impaired balance, and decreased lower extremity strength are common in people with obesity and may negatively affect daily activities and quality of life.
Participants will complete several commonly used clinical functional tests, including the 1-Minute Stair Climbing Test, 40-Meter Fast-Paced Walk Test, 2-Minute Walk Test, Timed Up and Go Test, and 30-Second Sit-to-Stand Test. In addition, cardiopulmonary exercise testing, balance assessment, and knee extensor muscle strength measurements will be performed.
The study will evaluate whether these simple and clinically applicable tests provide reliable results over repeated measurements and whether they are associated with objective indicators of physical function such as maximal oxygen consumption (VO₂max), balance performance, and muscle strength. The findings may help clinicians use practical and cost-effective tools to assess physical function in individuals with obesity.
Przegląd badań
Status
Warunki
Interwencja / Leczenie
Typ studiów
Zapisy (Szacowany)
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
- Dorosły
- Starszy dorosły
Akceptuje zdrowych ochotników
Metoda próbkowania
Badana populacja
Opis
Inclusion Criteria:
- Body mass index (BMI) ≥ 30 kg/m²
- Stable body weight during the last 3 months (less than ±2 kg change)
- Ability to perform daily living activities independently
Exclusion Criteria:
- History of cardiovascular disease
- History of pulmonary disease
- History of neurological disease
- Musculoskeletal injury affecting lower extremity function
- Presence of lower extremity prosthesis or severe deformity
- Major surgery within the previous 6 months
- Pregnancy
- Postpartum period
- Vestibular disorders affecting balance
- Visual impairments affecting test performance
- Hearing impairments affecting test performance
- Cognitive impairment limiting understanding of instructions
- Participation in strenuous physical activity before testing
- Use of medications affecting cardiopulmonary responses (e.g., beta-blockers)
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
1-Minute Stair Climbing Test
Ramy czasowe: 1 hour
|
A performance-based functional test used to assess stair climbing ability and lower extremity functional capacity.
The total number of completed stair cycles within 1 minute will be recorded.
|
1 hour
|
|
40-Meter Fast-Paced Walk Test
Ramy czasowe: 1 hour
|
A walking performance test used to evaluate fast-paced gait speed and functional mobility.
The time required to complete a total walking distance of 40 meters will be measured in seconds.
|
1 hour
|
|
2-Minute Walk Test
Ramy czasowe: 1 hour
|
A functional endurance test used to assess ambulatory capacity.
The total walking distance completed within 2 minutes will be recorded in meters.
|
1 hour
|
|
Timed Up and Go Test
Ramy czasowe: 1 hour
|
A functional mobility test used to assess dynamic balance and independent mobility.
The time required to stand up from a chair, walk 3 meters, return, and sit down will be measured in seconds.
|
1 hour
|
|
30-Second Sit-to-Stand Test
Ramy czasowe: 1 hour
|
A lower extremity functional strength and endurance test.
The total number of sit-to-stand repetitions completed within 30 seconds will be recorded.
|
1 hour
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Cardiopulmonary Exercise Testing (VO₂max)
Ramy czasowe: 1 hour
|
A maximal exercise test performed using the Modified Bruce Protocol on a treadmill to assess aerobic exercise capacity.
Maximal oxygen consumption (VO₂max) values will be recorded.
|
1 hour
|
|
Static Balance Assessment
Ramy czasowe: 1 hour
|
Balance performance will be evaluated using the PROKIN® computerized balance assessment system.
Parameters related to postural stability and body sway during static tasks will be recorded
|
1 hour
|
|
Knee Extensor Muscle Strength
Ramy czasowe: 1 hour
|
Isometric knee extensor muscle strength will be measured using a hand-held dynamometer.
Maximum voluntary contraction force will be recorded.
|
1 hour
|
|
Dynamic Balance Assessment
Ramy czasowe: 1 hour
|
Description: Balance performance will be evaluated using the PROKIN® computerized balance assessment system.
Parameters related to postural stability and body sway during static and dynamic tasks will be recorded
|
1 hour
|
Współpracownicy i badacze
Sponsor
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Szacowany)
Zakończenie podstawowe (Szacowany)
Ukończenie studiów (Szacowany)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- 21
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .