此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Trilogy Comparison Study - Adults

2021年1月14日 更新者:Philips Respironics

Comparing Known Modes of Ventilation Delivered by Trilogy Versus Conventional Mechanical Ventilators

The objective of this study (Part II) will be to compare the performance of the Trilogy device and a conventional ventilator (participant's current device). Both devices will be set to the participants' current mode and prescription settings.

研究概览

详细说明

A. Primary Hypothesis and end-point In patients with respiratory insufficiency, when compared to conventional ventilators, the Trilogy device achieves comparable level of gas exchange (measured as partial pressure of CO2 in arterial or venous blood)and SpO2 levels during various modes of ventilation.

B. Secondary Hypothesis and end-points In patients with respiratory insufficiency, when compared to conventional ventilators, the Trilogy device achieves comparable breathing pattern (tidal volume, respiratory rate, minute ventilation), hemodynamics (heart rate), and subjective measures of breathing comfort (measured by modified Borg dyspnea scale).

研究类型

介入性

注册 (实际的)

11

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

    • Manitoba
      • Winnipeg、Manitoba、加拿大、R3E 0Z3
        • University of Manitoba

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

21年 至 85年 (成人、年长者)

接受健康志愿者

不

有资格学习的性别

全部

描述

Inclusion Criteria:

  1. Age > 21 years of age; < 85 years of age
  2. Able to follow instructions
  3. Able to provide informed consent
  4. Considered clinically stable, with low flow oxygen requirements less than 15 LPM (or FIO2 less than 60 %) and PEEP no greater than 10 cm H2O.
  5. Requiring mechanical ventilation through nasal/facial mask,tracheostomy or endotracheal tube (ET Tube)

Exclusion Criteria:

  1. Clinically unstable, i.e.,

    1. Acute Respiratory Failure
    2. Participants with refractory hypotension defined as systolic blood pressure less than 90 mm Hg despite inotropic agents),
    3. Uncontrolled cardiac ischemia or arrhythmias,
    4. or as otherwise determined inappropriate for the study as determined by the investigator.
  2. Patients suffering from metastatic or terminal cancer and patients with do-not-resuscitate orders
  3. Pregnancy

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:治疗
  • 分配:随机化
  • 介入模型:交叉作业
  • 屏蔽:单身的

武器和干预

参与者组/臂
干预/治疗
实验性的:Trilogy
Trilogy Device
Exposure for one hour on the Trilogy ventilator
有源比较器:Standard of Care
Participants prescribed ventilator
Exposure to participants current ventilator

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Comparable Level of Gas Exchange (Measured as Partial Pressure of CO2 in Arterial or Venous Blood).
大体时间:After one hour of ventilator use
Blood gas was obtained for this study one hour after use of each device.
After one hour of ventilator use
Comparable Level of Gas Exchange SpO2 Levels During Various Modes of Ventilation.
大体时间:After one hour of ventilator use
Pulse Oximetry was measured after one hour of use of each ventilator.
After one hour of ventilator use

次要结果测量

结果测量
措施说明
大体时间
Tidal Volume
大体时间:One hour during ventilator use.
Tidal volume is the amount of air that moves in or out of the lungs with each respiratory cycle. It measures around 500 mL in an average healthy adult male and approximately 400 mL in a healthy female. Average tidal volume was compare after a hour of use of each device.
One hour during ventilator use.
Minute Ventilation
大体时间:One hour during ventilator use.
Minute ventilation is the volume of gas inhaled or exhaled from a person's lungs per minute. This was measured after one hour of use of each device.
One hour during ventilator use.
Hemodynamics (Heart Rate)
大体时间:One hour during ventilator use.
Number of beats per minute. Measured after one hour of use of each device.
One hour during ventilator use.

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:Steven Mink, MD、University of Manitoba

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2008年3月12日

初级完成 (实际的)

2009年2月5日

研究完成 (实际的)

2009年2月5日

研究注册日期

首次提交

2008年12月17日

首先提交符合 QC 标准的

2008年12月17日

首次发布 (估计)

2008年12月18日

研究记录更新

最后更新发布 (实际的)

2021年2月3日

上次提交的符合 QC 标准的更新

2021年1月14日

最后验证

2021年1月1日

更多信息

与本研究相关的术语

其他相关的 MeSH 术语

其他研究编号

  • MR-0609-TRI2-SS

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

是的

在美国制造并从美国出口的产品

是的

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.