The Comparison of Two Different Methods of Partial Inflation of Cuff for Facile Insertion of Laryngeal Mask Airway in Pediatric Patients
2014年3月4日 更新者:Jeong-Rim LEE、Yonsei University
Partial cuff inflation before insertion is generally used for laryngeal mask airway insertion in children.
However, it is not proven how much the cuff should be inflated.
The aim of this study is to compare efficacy between the method using the resting volume and the method using half the maximum volume for partial cuff inflation.
研究概览
地位
完全的
条件
研究类型
介入性
注册 (实际的)
78
阶段
- 不适用
联系人和位置
本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。
学习地点
-
-
-
Seoul、大韩民国、120-752
- Severance Hospital
-
-
参与标准
研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。
资格标准
适合学习的年龄
不超过 9年 (孩子)
接受健康志愿者
不
有资格学习的性别
全部
描述
Inclusion Criteria:
- children (0-9 years of age)
- children who is scheduled for elective surgery of short duration (less than 2 hr) undergoing general anesthesia using LMA-classic
Exclusion Criteria:
- patients with an abnormal airway
- patients with reactive airway disease
- patients with gastroesophageal reflux disease
- patients with chronic respiratory disease
- patients who has a history of an upper respiratory tract infection in the preceding 6-week period
学习计划
本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。
研究是如何设计的?
设计细节
- 分配:随机化
- 介入模型:并行分配
- 屏蔽:双倍的
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:静息容积组
|
80 patients are randomly allocated into two groups : resting volume group (n=40), half the maximum volume group (n=40).
In the resting volume group, the pilot balloon valve is connected to syringe without piston for keeping the valve open to the atmosphere and allowing the pressure within the cuff of LMA to equalize with atmospheric pressure.
In the half the maximum volume group, the cuff of LMA is completely emptied and then the cuff is filled with the half the maximum volume.
|
|
有源比较器:maximum volume group
|
80 patients are randomly allocated into two groups : resting volume group (n=40), half the maximum volume group (n=40).
In the resting volume group, the pilot balloon valve is connected to syringe without piston for keeping the valve open to the atmosphere and allowing the pressure within the cuff of LMA to equalize with atmospheric pressure.
In the half the maximum volume group, the cuff of LMA is completely emptied and then the cuff is filled with the half the maximum volume.
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
The intra-cuff pressure
大体时间:approximately 5 to 10 minutes after insertion of LMA.
|
1) After insertion of LMA, we confirm adequate ventilation.
And then we measure intra-cuff pressure using cuff pressure manometer.
2) After confirming adequate ventilation, tidal volumes are measured using spirometer sensor attached anesthesia machine.
Five corresponding inspiratory and expiratory tidal volumes are recorded and the difference between these is calculated as the leak volume.
The time that measures the intra-cuff pressure and leak volume is approximately 5 to 10 minutes after insertion of LMA.
|
approximately 5 to 10 minutes after insertion of LMA.
|
|
The leak volume
大体时间:approximately 5 to 10 minutes after insertion of LMA.
|
1) After insertion of LMA, we confirm adequate ventilation.
And then we measure intra-cuff pressure using cuff pressure manometer.
2) After confirming adequate ventilation, tidal volumes are measured using spirometer sensor attached anesthesia machine.
Five corresponding inspiratory and expiratory tidal volumes are recorded and the difference between these is calculated as the leak volume.
The time that measures the intra-cuff pressure and leak volume is approximately 5 to 10 minutes after insertion of LMA.
|
approximately 5 to 10 minutes after insertion of LMA.
|
合作者和调查者
在这里您可以找到参与这项研究的人员和组织。
出版物和有用的链接
负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。
研究记录日期
这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。
研究主要日期
学习开始
2011年9月1日
初级完成 (实际的)
2012年6月1日
研究完成 (实际的)
2012年6月1日
研究注册日期
首次提交
2011年9月14日
首先提交符合 QC 标准的
2011年9月15日
首次发布 (估计)
2011年9月16日
研究记录更新
最后更新发布 (估计)
2014年3月6日
上次提交的符合 QC 标准的更新
2014年3月4日
最后验证
2014年3月1日
更多信息
与本研究相关的术语
其他研究编号
- 1-2011-0046
药物和器械信息、研究文件
研究美国 FDA 监管的药品
不
研究美国 FDA 监管的设备产品
不
在美国制造并从美国出口的产品
不
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.