The Comparison of Two Different Methods of Partial Inflation of Cuff for Facile Insertion of Laryngeal Mask Airway in Pediatric Patients

4 maart 2014 bijgewerkt door: Jeong-Rim LEE, Yonsei University
Partial cuff inflation before insertion is generally used for laryngeal mask airway insertion in children. However, it is not proven how much the cuff should be inflated. The aim of this study is to compare efficacy between the method using the resting volume and the method using half the maximum volume for partial cuff inflation.

Studie Overzicht

Studietype

Ingrijpend

Inschrijving (Werkelijk)

78

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studie Locaties

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

Niet ouder dan 9 jaar (Kind)

Accepteert gezonde vrijwilligers

Nee

Geslachten die in aanmerking komen voor studie

Allemaal

Beschrijving

Inclusion Criteria:

  • children (0-9 years of age)
  • children who is scheduled for elective surgery of short duration (less than 2 hr) undergoing general anesthesia using LMA-classic

Exclusion Criteria:

  • patients with an abnormal airway
  • patients with reactive airway disease
  • patients with gastroesophageal reflux disease
  • patients with chronic respiratory disease
  • patients who has a history of an upper respiratory tract infection in the preceding 6-week period

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Toewijzing: Gerandomiseerd
  • Interventioneel model: Parallelle opdracht
  • Masker: Dubbele

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Experimenteel: rust volume groep
80 patients are randomly allocated into two groups : resting volume group (n=40), half the maximum volume group (n=40). In the resting volume group, the pilot balloon valve is connected to syringe without piston for keeping the valve open to the atmosphere and allowing the pressure within the cuff of LMA to equalize with atmospheric pressure. In the half the maximum volume group, the cuff of LMA is completely emptied and then the cuff is filled with the half the maximum volume.
Actieve vergelijker: maximum volume group
80 patients are randomly allocated into two groups : resting volume group (n=40), half the maximum volume group (n=40). In the resting volume group, the pilot balloon valve is connected to syringe without piston for keeping the valve open to the atmosphere and allowing the pressure within the cuff of LMA to equalize with atmospheric pressure. In the half the maximum volume group, the cuff of LMA is completely emptied and then the cuff is filled with the half the maximum volume.

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
The intra-cuff pressure
Tijdsspanne: approximately 5 to 10 minutes after insertion of LMA.
1) After insertion of LMA, we confirm adequate ventilation. And then we measure intra-cuff pressure using cuff pressure manometer. 2) After confirming adequate ventilation, tidal volumes are measured using spirometer sensor attached anesthesia machine. Five corresponding inspiratory and expiratory tidal volumes are recorded and the difference between these is calculated as the leak volume. The time that measures the intra-cuff pressure and leak volume is approximately 5 to 10 minutes after insertion of LMA.
approximately 5 to 10 minutes after insertion of LMA.
The leak volume
Tijdsspanne: approximately 5 to 10 minutes after insertion of LMA.
1) After insertion of LMA, we confirm adequate ventilation. And then we measure intra-cuff pressure using cuff pressure manometer. 2) After confirming adequate ventilation, tidal volumes are measured using spirometer sensor attached anesthesia machine. Five corresponding inspiratory and expiratory tidal volumes are recorded and the difference between these is calculated as the leak volume. The time that measures the intra-cuff pressure and leak volume is approximately 5 to 10 minutes after insertion of LMA.
approximately 5 to 10 minutes after insertion of LMA.

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Publicaties en nuttige links

De persoon die verantwoordelijk is voor het invoeren van informatie over het onderzoek stelt deze publicaties vrijwillig ter beschikking. Dit kan gaan over alles wat met het onderzoek te maken heeft.

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start

1 september 2011

Primaire voltooiing (Werkelijk)

1 juni 2012

Studie voltooiing (Werkelijk)

1 juni 2012

Studieregistratiedata

Eerst ingediend

14 september 2011

Eerst ingediend dat voldeed aan de QC-criteria

15 september 2011

Eerst geplaatst (Schatting)

16 september 2011

Updates van studierecords

Laatste update geplaatst (Schatting)

6 maart 2014

Laatste update ingediend die voldeed aan QC-criteria

4 maart 2014

Laatst geverifieerd

1 maart 2014

Meer informatie

Termen gerelateerd aan deze studie

Andere studie-ID-nummers

  • 1-2011-0046

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

product vervaardigd in en geëxporteerd uit de V.S.

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren