The Comparison of Two Different Methods of Partial Inflation of Cuff for Facile Insertion of Laryngeal Mask Airway in Pediatric Patients
2014. március 4. frissítette: Jeong-Rim LEE, Yonsei University
Partial cuff inflation before insertion is generally used for laryngeal mask airway insertion in children.
However, it is not proven how much the cuff should be inflated.
The aim of this study is to compare efficacy between the method using the resting volume and the method using half the maximum volume for partial cuff inflation.
A tanulmány áttekintése
Állapot
Befejezve
Tanulmány típusa
Beavatkozó
Beiratkozás (Tényleges)
78
Fázis
- Nem alkalmazható
Kapcsolatok és helyek
Ez a rész a vizsgálatot végzők elérhetőségeit, valamint a vizsgálat lefolytatásának helyére vonatkozó információkat tartalmazza.
Tanulmányi helyek
-
-
-
Seoul, Koreai Köztársaság, 120-752
- Severance Hospital
-
-
Részvételi kritériumok
A kutatók olyan embereket keresnek, akik megfelelnek egy bizonyos leírásnak, az úgynevezett jogosultsági kritériumoknak. Néhány példa ezekre a kritériumokra a személy általános egészségi állapota vagy a korábbi kezelések.
Jogosultsági kritériumok
Tanulmányozható életkorok
Nem régebbi, mint 9 év (Gyermek)
Egészséges önkénteseket fogad
Nem
Tanulmányozható nemek
Összes
Leírás
Inclusion Criteria:
- children (0-9 years of age)
- children who is scheduled for elective surgery of short duration (less than 2 hr) undergoing general anesthesia using LMA-classic
Exclusion Criteria:
- patients with an abnormal airway
- patients with reactive airway disease
- patients with gastroesophageal reflux disease
- patients with chronic respiratory disease
- patients who has a history of an upper respiratory tract infection in the preceding 6-week period
Tanulási terv
Ez a rész a vizsgálati terv részleteit tartalmazza, beleértve a vizsgálat megtervezését és a vizsgálat mérését.
Hogyan készül a tanulmány?
Tervezési részletek
- Kiosztás: Véletlenszerűsített
- Beavatkozó modell: Párhuzamos hozzárendelés
- Maszkolás: Kettős
Fegyverek és beavatkozások
Résztvevő csoport / kar |
Beavatkozás / kezelés |
|---|---|
|
Kísérleti: nyugalmi térfogatcsoport
|
80 patients are randomly allocated into two groups : resting volume group (n=40), half the maximum volume group (n=40).
In the resting volume group, the pilot balloon valve is connected to syringe without piston for keeping the valve open to the atmosphere and allowing the pressure within the cuff of LMA to equalize with atmospheric pressure.
In the half the maximum volume group, the cuff of LMA is completely emptied and then the cuff is filled with the half the maximum volume.
|
|
Aktív összehasonlító: maximum volume group
|
80 patients are randomly allocated into two groups : resting volume group (n=40), half the maximum volume group (n=40).
In the resting volume group, the pilot balloon valve is connected to syringe without piston for keeping the valve open to the atmosphere and allowing the pressure within the cuff of LMA to equalize with atmospheric pressure.
In the half the maximum volume group, the cuff of LMA is completely emptied and then the cuff is filled with the half the maximum volume.
|
Mit mér a tanulmány?
Elsődleges eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
|---|---|---|
|
The intra-cuff pressure
Időkeret: approximately 5 to 10 minutes after insertion of LMA.
|
1) After insertion of LMA, we confirm adequate ventilation.
And then we measure intra-cuff pressure using cuff pressure manometer.
2) After confirming adequate ventilation, tidal volumes are measured using spirometer sensor attached anesthesia machine.
Five corresponding inspiratory and expiratory tidal volumes are recorded and the difference between these is calculated as the leak volume.
The time that measures the intra-cuff pressure and leak volume is approximately 5 to 10 minutes after insertion of LMA.
|
approximately 5 to 10 minutes after insertion of LMA.
|
|
The leak volume
Időkeret: approximately 5 to 10 minutes after insertion of LMA.
|
1) After insertion of LMA, we confirm adequate ventilation.
And then we measure intra-cuff pressure using cuff pressure manometer.
2) After confirming adequate ventilation, tidal volumes are measured using spirometer sensor attached anesthesia machine.
Five corresponding inspiratory and expiratory tidal volumes are recorded and the difference between these is calculated as the leak volume.
The time that measures the intra-cuff pressure and leak volume is approximately 5 to 10 minutes after insertion of LMA.
|
approximately 5 to 10 minutes after insertion of LMA.
|
Együttműködők és nyomozók
Itt találhatja meg a tanulmányban érintett személyeket és szervezeteket.
Szponzor
Publikációk és hasznos linkek
A vizsgálattal kapcsolatos információk beviteléért felelős személy önkéntesen bocsátja rendelkezésre ezeket a kiadványokat. Ezek bármiről szólhatnak, ami a tanulmányhoz kapcsolódik.
Tanulmányi rekorddátumok
Ezek a dátumok nyomon követik a ClinicalTrials.gov webhelyre benyújtott vizsgálati rekordok és összefoglaló eredmények benyújtásának folyamatát. A vizsgálati feljegyzéseket és a jelentett eredményeket a Nemzeti Orvostudományi Könyvtár (NLM) felülvizsgálja, hogy megbizonyosodjon arról, hogy megfelelnek-e az adott minőség-ellenőrzési szabványoknak, mielőtt közzéteszik őket a nyilvános weboldalon.
Tanulmány főbb dátumok
Tanulmány kezdete
2011. szeptember 1.
Elsődleges befejezés (Tényleges)
2012. június 1.
A tanulmány befejezése (Tényleges)
2012. június 1.
Tanulmányi regisztráció dátumai
Először benyújtva
2011. szeptember 14.
Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak
2011. szeptember 15.
Első közzététel (Becslés)
2011. szeptember 16.
Tanulmányi rekordok frissítései
Utolsó frissítés közzétéve (Becslés)
2014. március 6.
Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak
2014. március 4.
Utolsó ellenőrzés
2014. március 1.
Több információ
A tanulmányhoz kapcsolódó kifejezések
Egyéb vizsgálati azonosító számok
- 1-2011-0046
Gyógyszer- és eszközinformációk, tanulmányi dokumentumok
Egy amerikai FDA által szabályozott gyógyszerkészítményt tanulmányoz
Nem
Egy amerikai FDA által szabályozott eszközterméket tanulmányoz
Nem
az Egyesült Államokban gyártott és onnan exportált termék
Nem
Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .
Klinikai vizsgálatok a The cuff inflation by the resting volume
-
University of North Carolina, Chapel HillAktív, nem toborzóSzagláshiány | Szaglási zavarok | Akut COVID-19 utáni szindróma | Hosszú távú COVID-19Egyesült Államok