经导管主动脉瓣植入术后新发持续性左束支传导阻滞患者的高度房室传导阻滞的动态心电图监测。 “母马”研究 (MARE)
The purpose of this study is to determine the incidence and predictors of high degree or complete atrioventricular block (AVB) (paroxysmal or persistent) in patients with new-onset persistent left bundle branch block (NOP-LBBB) following transcatheter aortic valve implantation (TAVI) and to evaluate the usefulness of the Reveal LINQ® insertable Cardiac Monitor (ICM) (Medtronic, Inc., Minneapolis, USA) for the detection of significant arrhythmias in patients with NOP-LBBB following TAVI.
研究概览
详细说明
This is a prospective observational study including patients undergoing TAVI with either self- or balloon-expandable valves. After the procedure, patients will be on ECG monitoring during the hospitalization period (or at least 72 hours), and an ECG will be performed daily until hospital discharge in all patients. Patients with new-onset persistent LBBB at hospital discharge (new-onset LBBB of a duration of at least 48 h which persists at hospital discharge, at least 3 days and up to 15 days after the procedure) will receive an implantable loop recorder Reveal ICM LINQ®, which will be implanted subcutaneously to record adequate QRS complexes and P waves. The patients will be followed in outpatient clinic visits at 1, 12, 24 and 36 months after TAVR, or if symptoms suggestive of cardiac origin or relevant arrhythmic events occur. The device will be manually interrogated in each visit. Phone contacts will be also carried out every three months.
研究类型
注册 (估计的)
阶段
- 不适用
联系人和位置
学习地点
-
-
Quebec
-
Québec、Quebec、加拿大、G1V 4G5
- 招聘中
- IUCPQ
-
接触:
- Emilie Pelletier Beaumont, M.Sc.
- 电话号码:3929 418-656-8711
- 邮箱:Emilie.Pelletier-Beaumont@criucpq.ulaval.ca
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
Inclusion Criteria:
-Patients undergoing TAVI with either balloon or self-expandable valves who develop new-onset LBBB persistent at hospital discharge, at least 3 days after the procedure
Exclusion Criteria:
- Failure to provide informed consent
- Baseline pacemaker/defibrillator or pacemaker/defibrillator implanted during the hospitalization period following the TAVI procedure
- Pre-existing complete LBBB
- Patients with a life-expectancy of less than 2 years
学习计划
研究是如何设计的?
设计细节
- 主要用途:诊断
- 分配:不适用
- 介入模型:单组作业
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:植入式循环记录仪 Reveal ICM LINQ®,
|
研究衡量的是什么?
主要结果指标
结果测量 |
大体时间 |
|---|---|
|
- 高度或完全性 AVB 的发生率和时间
大体时间:1年
|
1年
|
|
-IRL 确定的导致治疗改变或主要不良事件的心律失常事件的发生率
大体时间:1年
|
1年
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
-AVB的高度或完成率
大体时间:TAVI 手术后的第一个月内
|
TAVI 手术后的第一个月内
|
|
|
-AVB的高度或完成率
大体时间:6个月的随访
|
6个月的随访
|
|
|
-高度或完全AVB率
大体时间:24个月的随访
|
24个月的随访
|
|
|
-高度或完全AVB率
大体时间:36个月的随访
|
36个月的随访
|
|
|
-新房颤或室性心律失常的发生率
大体时间:TAVI 手术后的前 3 年内
|
TAVI 手术后的前 3 年内
|
|
|
- 左心室功能和二尖瓣反流随时间的变化
大体时间:TAVI 手术后的前 3 年内
|
TAVI 手术后的前 3 年内
|
|
|
-Electrocardiographic and device-related factors predicting the occurence of high degree or complete AVB in patients with new-onset LBBB after TAVI
大体时间:Within the first 3 years following TAVI procedure
|
Periprocedural results of TAVI of patients with NOP-LVV will be used to characterize predictors of high degree or complete AVB. Moreover, electrocardiographic characteristics at hospital discharge of patients with NOP-LVV will also be used to characterize predictors of high degree or complete AVB. |
Within the first 3 years following TAVI procedure
|
合作者和调查者
调查人员
- 首席研究员:Josep Rodes, MD、Fondation IUCPQ
出版物和有用的链接
一般刊物
- Krahn AD, Klein GJ, Yee R, Takle-Newhouse T, Norris C. Use of an extended monitoring strategy in patients with problematic syncope. Reveal Investigators. Circulation. 1999 Jan 26;99(3):406-10. doi: 10.1161/01.cir.99.3.406.
- Lombardi F, Calosso E, Mascioli G, Marangoni E, Donato A, Rossi S, Pala M, Foti F, Lunati M. Utility of implantable loop recorder (Reveal Plus) in the diagnosis of unexplained syncope. Europace. 2005 Jan;7(1):19-24. doi: 10.1016/j.eupc.2004.09.003.
- Epstein AE, DiMarco JP, Ellenbogen KA, Estes NA 3rd, Freedman RA, Gettes LS, Gillinov AM, Gregoratos G, Hammill SC, Hayes DL, Hlatky MA, Newby LK, Page RL, Schoenfeld MH, Silka MJ, Stevenson LW, Sweeney MO; American College of Cardiology Foundation; American Heart Association Task Force on Practice Guidelines; Heart Rhythm Society. 2012 ACCF/AHA/HRS focused update incorporated into the ACCF/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines and the Heart Rhythm Society. Circulation. 2013 Jan 22;127(3):e283-352. doi: 10.1161/CIR.0b013e318276ce9b. Epub 2012 Dec 19. No abstract available.
- Surawicz B, Childers R, Deal BJ, Gettes LS, Bailey JJ, Gorgels A, Hancock EW, Josephson M, Kligfield P, Kors JA, Macfarlane P, Mason JW, Mirvis DM, Okin P, Pahlm O, Rautaharju PM, van Herpen G, Wagner GS, Wellens H; American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; American College of Cardiology Foundation; Heart Rhythm Society. AHA/ACCF/HRS recommendations for the standardization and interpretation of the electrocardiogram: part III: intraventricular conduction disturbances: a scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College of Cardiology Foundation; and the Heart Rhythm Society. Endorsed by the International Society for Computerized Electrocardiology. J Am Coll Cardiol. 2009 Mar 17;53(11):976-81. doi: 10.1016/j.jacc.2008.12.013. No abstract available.
- Kappetein AP, Head SJ, Genereux P, Piazza N, van Mieghem NM, Blackstone EH, Brott TG, Cohen DJ, Cutlip DE, van Es GA, Hahn RT, Kirtane AJ, Krucoff MW, Kodali S, Mack MJ, Mehran R, Rodes-Cabau J, Vranckx P, Webb JG, Windecker S, Serruys PW, Leon MB; Valve Academic Research Consortium (VARC)-2. Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document (VARC-2). Eur J Cardiothorac Surg. 2012 Nov;42(5):S45-60. doi: 10.1093/ejcts/ezs533. Epub 2012 Oct 1.
- Leon MB, Piazza N, Nikolsky E, Blackstone EH, Cutlip DE, Kappetein AP, Krucoff MW, Mack M, Mehran R, Miller C, Morel MA, Petersen J, Popma JJ, Takkenberg JJ, Vahanian A, van Es GA, Vranckx P, Webb JG, Windecker S, Serruys PW. Standardized endpoint definitions for Transcatheter Aortic Valve Implantation clinical trials: a consensus report from the Valve Academic Research Consortium. J Am Coll Cardiol. 2011 Jan 18;57(3):253-69. doi: 10.1016/j.jacc.2010.12.005. Epub 2011 Jan 7.
- Thompson R, Mitchell A, Ahmed M, Towers M, Yacoub M. Conduction defects in aortic valve disease. Am Heart J. 1979 Jul;98(1):3-10. doi: 10.1016/0002-8703(79)90313-2. No abstract available.
- El-Khally Z, Thibault B, Staniloae C, Theroux P, Dubuc M, Roy D, Guerra P, Macle L, Talajic M. Prognostic significance of newly acquired bundle branch block after aortic valve replacement. Am J Cardiol. 2004 Oct 15;94(8):1008-11. doi: 10.1016/j.amjcard.2004.06.055.
- Thomas JL, Dickstein RA, Parker FB Jr, Potts JL, Poirier RA, Fruehan CT, Eich RH. Prognostic significance of the development of left bundle conduction defects following aortic valve replacement. J Thorac Cardiovasc Surg. 1982 Sep;84(3):382-6.
- Foppl M, Hoffmann A, Amann FW, Roth J, Stulz P, Hasse J, Gradel E, Burckhardt D. Sudden cardiac death after aortic valve surgery: incidence and concomitant factors. Clin Cardiol. 1989 Apr;12(4):202-7. doi: 10.1002/clc.4960120405.
- van der Boon RM, Nuis RJ, Van Mieghem NM, Jordaens L, Rodes-Cabau J, van Domburg RT, Serruys PW, Anderson RH, de Jaegere PP. New conduction abnormalities after TAVI--frequency and causes. Nat Rev Cardiol. 2012 May 1;9(8):454-63. doi: 10.1038/nrcardio.2012.58.
- Dou J, Xia L, Zhang Y, Shou G, Wei Q, Liu F, Crozier S. Mechanical analysis of congestive heart failure caused by bundle branch block based on an electromechanical canine heart model. Phys Med Biol. 2009 Jan 21;54(2):353-71. doi: 10.1088/0031-9155/54/2/012. Epub 2008 Dec 19.
- Piazza N, Nuis RJ, Tzikas A, Otten A, Onuma Y, Garcia-Garcia H, Schultz C, van Domburg R, van Es GA, van Geuns R, de Jaegere P, Serruys PW. Persistent conduction abnormalities and requirements for pacemaking six months after transcatheter aortic valve implantation. EuroIntervention. 2010 Sep;6(4):475-84. doi: 10.4244/EIJ30V6I4A80.
- Houthuizen P, Van Garsse LA, Poels TT, de Jaegere P, van der Boon RM, Swinkels BM, Ten Berg JM, van der Kley F, Schalij MJ, Baan J Jr, Cocchieri R, Brueren GR, van Straten AH, den Heijer P, Bentala M, van Ommen V, Kluin J, Stella PR, Prins MH, Maessen JG, Prinzen FW. Left bundle-branch block induced by transcatheter aortic valve implantation increases risk of death. Circulation. 2012 Aug 7;126(6):720-8. doi: 10.1161/CIRCULATIONAHA.112.101055. Epub 2012 Jul 12.
- Testa L, Latib A, De Marco F, De Carlo M, Agnifili M, Latini RA, Petronio AS, Ettori F, Poli A, De Servi S, Ramondo A, Napodano M, Klugmann S, Ussia GP, Tamburino C, Brambilla N, Colombo A, Bedogni F. Clinical impact of persistent left bundle-branch block after transcatheter aortic valve implantation with CoreValve Revalving System. Circulation. 2013 Mar 26;127(12):1300-7. doi: 10.1161/CIRCULATIONAHA.112.001099. Epub 2013 Feb 26.
- Urena M, Mok M, Serra V, Dumont E, Nombela-Franco L, DeLarochelliere R, Doyle D, Igual A, Larose E, Amat-Santos I, Cote M, Cuellar H, Pibarot P, de Jaegere P, Philippon F, Garcia del Blanco B, Rodes-Cabau J. Predictive factors and long-term clinical consequences of persistent left bundle branch block following transcatheter aortic valve implantation with a balloon-expandable valve. J Am Coll Cardiol. 2012 Oct 30;60(18):1743-52. doi: 10.1016/j.jacc.2012.07.035. Epub 2012 Oct 3.
- Moya A, Garcia-Civera R, Croci F, Menozzi C, Brugada J, Ammirati F, Del Rosso A, Bellver-Navarro A, Garcia-Sacristan J, Bortnik M, Mont L, Ruiz-Granell R, Navarro X; Bradycardia detection in Bundle Branch Block (B4) study. Diagnosis, management, and outcomes of patients with syncope and bundle branch block. Eur Heart J. 2011 Jun;32(12):1535-41. doi: 10.1093/eurheartj/ehr071. Epub 2011 Mar 28.
- Furukawa T, Maggi R, Bertolone C, Fontana D, Brignole M. Additional diagnostic value of very prolonged observation by implantable loop recorder in patients with unexplained syncope. J Cardiovasc Electrophysiol. 2012 Jan;23(1):67-71. doi: 10.1111/j.1540-8167.2011.02133.x. Epub 2011 Jul 21.
- Paruchuri V, Adhaduk M, Garikipati NV, Steinberg JS, Mittal S. Clinical utility of a novel wireless implantable loop recorder in the evaluation of patients with unexplained syncope. Heart Rhythm. 2011 Jun;8(6):858-63. doi: 10.1016/j.hrthm.2011.01.039. Epub 2011 Feb 2.
- Krahn AD, Klein GJ, Yee R, Hoch JS, Skanes AC. Cost implications of testing strategy in patients with syncope: randomized assessment of syncope trial. J Am Coll Cardiol. 2003 Aug 6;42(3):495-501. doi: 10.1016/s0735-1097(03)00659-4.
- Crossley GH, Boyle A, Vitense H, Chang Y, Mead RH; CONNECT Investigators. The CONNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) trial: the value of wireless remote monitoring with automatic clinician alerts. J Am Coll Cardiol. 2011 Mar 8;57(10):1181-9. doi: 10.1016/j.jacc.2010.12.012. Epub 2011 Jan 20.
- Goldberger JJ, Cain ME, Hohnloser SH, Kadish AH, Knight BP, Lauer MS, Maron BJ, Page RL, Passman RS, Siscovick D, Siscovick D, Stevenson WG, Zipes DP; American Heart Association; American College of Cardiology Foundation; Heart Rhythm Society. American Heart Association/American College of Cardiology Foundation/Heart Rhythm Society scientific statement on noninvasive risk stratification techniques for identifying patients at risk for sudden cardiac death: a scientific statement from the American Heart Association Council on Clinical Cardiology Committee on Electrocardiography and Arrhythmias and Council on Epidemiology and Prevention. Circulation. 2008 Sep 30;118(14):1497-1518. No abstract available.
- Muntane-Carol G, Urena M, Nombela-Franco L, Amat-Santos I, Kleiman N, Munoz-Garcia A, Atienza F, Serra V, Deyell MW, Veiga-Fernandez G, Masson JB, Canadas-Godoy V, Himbert D, Castrodeza J, Elizaga J, Francisco Pascual J, Webb JG, de la Torre Hernandez JM, Asmarats L, Pelletier-Beaumont E, Philippon F, Rodes-Cabau J. Arrhythmic burden in patients with new-onset persistent left bundle branch block after transcatheter aortic valve replacement: 2-year results of the MARE study. Europace. 2021 Feb 5;23(2):254-263. doi: 10.1093/europace/euaa213.
- Rodes-Cabau J, Urena M, Nombela-Franco L, Amat-Santos I, Kleiman N, Munoz-Garcia A, Atienza F, Serra V, Deyell MW, Veiga-Fernandez G, Masson JB, Canadas-Godoy V, Himbert D, Castrodeza J, Elizaga J, Francisco Pascual J, Webb JG, de la Torre JM, Asmarats L, Pelletier-Beaumont E, Philippon F. Arrhythmic Burden as Determined by Ambulatory Continuous Cardiac Monitoring in Patients With New-Onset Persistent Left Bundle Branch Block Following Transcatheter Aortic Valve Replacement: The MARE Study. JACC Cardiovasc Interv. 2018 Aug 13;11(15):1495-1505. doi: 10.1016/j.jcin.2018.04.016. Epub 2018 Jul 18.
- Piazza N, de Jaegere P, Schultz C, Becker AE, Serruys PW, Anderson RH. Anatomy of the aortic valvar complex and its implications for transcatheter implantation of the aortic valve. Circ Cardiovasc Interv. 2008 Aug;1(1):74-81. doi: 10.1161/CIRCINTERVENTIONS.108.780858.
- Task Force members; Brignole M, Vardas P, Hoffman E, Huikuri H, Moya A, Ricci R, Sulke N, Wieling W; EHRA Scientific Documents Committee; Auricchio A, Lip GY, Almendral J, Kirchhof P, Aliot E, Gasparini M, Braunschweig F; Document Reviewers; Lip GY, Almendral J, Kirchhof P, Botto GL; EHRA Scientific Documents Committee. Indications for the use of diagnostic implantable and external ECG loop recorders. Europace. 2009 May;11(5):671-87. doi: 10.1093/europace/eup097. No abstract available.
研究记录日期
研究主要日期
学习开始
初级完成 (实际的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (估计的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.