In Vitro Microstructural and Mechanical Analysis of Waste Material From Total Knee Arthroplasty for the Study of Innovative Solutions in the Treatment of Joint and Ligament Pathologies (TIB PLAT)

2026年4月30日 更新者:Stefano Zaffagnini

In orthopedic surgical practice, there is an increasing incidence of degenerative joint diseases, due to the rising average age of the population, as well as ligament injuries resulting from the growing participation in sports activities. The knee joint, in particular, is the most affected by these conditions, which, given their heterogeneous nature, impact patients across a wide age range.

Knee pathologies, often interconnected (with a higher incidence of degenerative diseases following ligamentous and/or meniscal injuries), are particularly debilitating for patients and entail high costs for the national healthcare system, which are expected to increase over time.

Scientific efforts in the field of knee surgery are therefore focused on achieving an increasingly detailed understanding of pathological conditions, as well as on the development of innovative technologies to support surgical and clinical practice.

Carrying out such analyses and developing new technologies inevitably involves experimental laboratory studies of joint tissues. The study of waste material obtained from surgical procedures represents a fundamental resource in this context and has always been used safely, with no additional invasiveness for the patient. A vast amount of information derived from laboratory analyses of discarded tissue has contributed to improving clinical practice and has led to the development of solutions that are now part of routine surgical use.

Recent technologies allow increasingly accurate evaluation of both the structure and mechanical properties of discarded tissue explanted during surgery. For example, structural assessment using micro-CT enables visualization and analysis of the interface between bone tissue, ligamentous structures, and surgical implants with micrometric precision. This makes it possible to determine tissue density, orientation, and material quality, distinguishing between different boundary conditions and physiopathological states of the tissues. Such analyses can also be performed under conditions close to those characterizing the joint in vivo, both in terms of tissue immersed in fluid and with respect to mechanical loads applied to deform the tissue. Furthermore, it is possible to reconstruct the structural interaction between human tissue and external materials used in surgery, such as screws, plates, anchoring devices, etc.

These instruments therefore make it possible to surpass the level of detail achievable with conventional diagnostic and research equipment used over the years, and to investigate with increasing accuracy the onset and progression of a pathology, the condition of the involved tissues, and to predict functional recovery of the treated site following the application of anchoring devices in the operating room. These new analyses also enable the study of innovative solutions for tissue repair and reconstruction, such as patient-specific customized devices and/or new materials produced using 3D printing technology, without posing any risk to the patient during surgery.

研究概览

地位

完全的

研究类型

观察性的

注册 (实际的)

29

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

      • Bologna、意大利、40136
        • IRCCS Rizzoli Ortopedic Institute

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 成人
  • 年长者

接受健康志愿者

不

取样方法

非概率样本

研究人群

Waste materials obtained from primary total knee arthroplasty procedures will be used. The collected material will mainly consist of osteochondral tissue from the patient's tibial plateau. This portion of tissue is routinely removed during the resection of the proximal (tibia) and distal (femur) bone components, which is necessary for the implantation of the prosthetic components. The resection and subsequent removal of the tibial plateau constitute a standard procedure and a mandatory step in primary total knee arthroplasty. This procedure will be performed intraoperatively by the medical staff of the coordinating investigator (Orthopaedic and Traumatology Clinic II). The waste material will be placed in a dedicated single-use container and transferred to the Research Center laboratories for analysis, in accordance with the above-mentioned internal procedure.

描述

Inclusion Criteria:

  • Total knee arthroplasty
  • Kellgren-Lawrence grade II, III, or IV osteoarthritis;
  • age < 85 years;
  • BMI < 35

Exclusion Criteria:

  • History/evidence of previous partial (unicompartmental) knee arthroplasty;
  • positivity for viral infections such as HIV, HBV, or HCV;
  • inability to provide informed consent.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Microstructural properties of the explanted tissue
大体时间:At least 24 months
Porosity of the subchondral bone tissue
At least 24 months

次要结果测量

结果测量
措施说明
大体时间
Load transfer mechanisms
大体时间:At least 24 months
Load transfer mechanisms from the residual cartilage tissue to the underlying bone tissue. Load transfer from the residual cartilage to the subchondral bone can be represented by the stress (Pa) developed in the underlying bone
At least 24 months
Bone/Tissue Density
大体时间:At least 24 months
Tissue density at the anterior cruciate ligament insertion will be quantified using micro-computed tomography and expressed as bone mineral density (mg HA/cm³).
At least 24 months
Structural Organization
大体时间:At least 24 months
Tissue orientation and homogeneity at the ligament insertion will be evaluated using histological and histomorphometric analysis and expressed using quantitative indices (e.g., orientation index, % area uniformity).
At least 24 months

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2021年11月30日

初级完成 (实际的)

2024年3月7日

研究完成 (实际的)

2025年1月7日

研究注册日期

首次提交

2026年4月21日

首先提交符合 QC 标准的

2026年4月30日

首次发布 (实际的)

2026年5月6日

研究记录更新

最后更新发布 (实际的)

2026年5月6日

上次提交的符合 QC 标准的更新

2026年4月30日

最后验证

2026年4月1日

更多信息

与本研究相关的术语

其他相关的 MeSH 术语

其他研究编号

  • TIB PLAT

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅