In Vitro Microstructural and Mechanical Analysis of Waste Material From Total Knee Arthroplasty for the Study of Innovative Solutions in the Treatment of Joint and Ligament Pathologies (TIB PLAT)

30 de abril de 2026 atualizado por: Stefano Zaffagnini

In orthopedic surgical practice, there is an increasing incidence of degenerative joint diseases, due to the rising average age of the population, as well as ligament injuries resulting from the growing participation in sports activities. The knee joint, in particular, is the most affected by these conditions, which, given their heterogeneous nature, impact patients across a wide age range.

Knee pathologies, often interconnected (with a higher incidence of degenerative diseases following ligamentous and/or meniscal injuries), are particularly debilitating for patients and entail high costs for the national healthcare system, which are expected to increase over time.

Scientific efforts in the field of knee surgery are therefore focused on achieving an increasingly detailed understanding of pathological conditions, as well as on the development of innovative technologies to support surgical and clinical practice.

Carrying out such analyses and developing new technologies inevitably involves experimental laboratory studies of joint tissues. The study of waste material obtained from surgical procedures represents a fundamental resource in this context and has always been used safely, with no additional invasiveness for the patient. A vast amount of information derived from laboratory analyses of discarded tissue has contributed to improving clinical practice and has led to the development of solutions that are now part of routine surgical use.

Recent technologies allow increasingly accurate evaluation of both the structure and mechanical properties of discarded tissue explanted during surgery. For example, structural assessment using micro-CT enables visualization and analysis of the interface between bone tissue, ligamentous structures, and surgical implants with micrometric precision. This makes it possible to determine tissue density, orientation, and material quality, distinguishing between different boundary conditions and physiopathological states of the tissues. Such analyses can also be performed under conditions close to those characterizing the joint in vivo, both in terms of tissue immersed in fluid and with respect to mechanical loads applied to deform the tissue. Furthermore, it is possible to reconstruct the structural interaction between human tissue and external materials used in surgery, such as screws, plates, anchoring devices, etc.

These instruments therefore make it possible to surpass the level of detail achievable with conventional diagnostic and research equipment used over the years, and to investigate with increasing accuracy the onset and progression of a pathology, the condition of the involved tissues, and to predict functional recovery of the treated site following the application of anchoring devices in the operating room. These new analyses also enable the study of innovative solutions for tissue repair and reconstruction, such as patient-specific customized devices and/or new materials produced using 3D printing technology, without posing any risk to the patient during surgery.

Visão geral do estudo

Status

Concluído

Tipo de estudo

Observacional

Inscrição (Real)

29

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

      • Bologna, Itália, 40136
        • IRCCS Rizzoli Ortopedic Institute

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Adulto
  • Adulto mais velho

Aceita Voluntários Saudáveis

Não

Método de amostragem

Amostra Não Probabilística

População do estudo

Waste materials obtained from primary total knee arthroplasty procedures will be used. The collected material will mainly consist of osteochondral tissue from the patient's tibial plateau. This portion of tissue is routinely removed during the resection of the proximal (tibia) and distal (femur) bone components, which is necessary for the implantation of the prosthetic components. The resection and subsequent removal of the tibial plateau constitute a standard procedure and a mandatory step in primary total knee arthroplasty. This procedure will be performed intraoperatively by the medical staff of the coordinating investigator (Orthopaedic and Traumatology Clinic II). The waste material will be placed in a dedicated single-use container and transferred to the Research Center laboratories for analysis, in accordance with the above-mentioned internal procedure.

Descrição

Inclusion Criteria:

  • Total knee arthroplasty
  • Kellgren-Lawrence grade II, III, or IV osteoarthritis;
  • age < 85 years;
  • BMI < 35

Exclusion Criteria:

  • History/evidence of previous partial (unicompartmental) knee arthroplasty;
  • positivity for viral infections such as HIV, HBV, or HCV;
  • inability to provide informed consent.

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Microstructural properties of the explanted tissue
Prazo: At least 24 months
Porosity of the subchondral bone tissue
At least 24 months

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Load transfer mechanisms
Prazo: At least 24 months
Load transfer mechanisms from the residual cartilage tissue to the underlying bone tissue. Load transfer from the residual cartilage to the subchondral bone can be represented by the stress (Pa) developed in the underlying bone
At least 24 months
Bone/Tissue Density
Prazo: At least 24 months
Tissue density at the anterior cruciate ligament insertion will be quantified using micro-computed tomography and expressed as bone mineral density (mg HA/cm³).
At least 24 months
Structural Organization
Prazo: At least 24 months
Tissue orientation and homogeneity at the ligament insertion will be evaluated using histological and histomorphometric analysis and expressed using quantitative indices (e.g., orientation index, % area uniformity).
At least 24 months

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

30 de novembro de 2021

Conclusão Primária (Real)

7 de março de 2024

Conclusão do estudo (Real)

7 de janeiro de 2025

Datas de inscrição no estudo

Enviado pela primeira vez

21 de abril de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

30 de abril de 2026

Primeira postagem (Real)

6 de maio de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

6 de maio de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

30 de abril de 2026

Última verificação

1 de abril de 2026

Mais Informações

Termos relacionados a este estudo

Termos MeSH relevantes adicionais

Outros números de identificação do estudo

  • TIB PLAT

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever