- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT07571512
In Vitro Microstructural and Mechanical Analysis of Waste Material From Total Knee Arthroplasty for the Study of Innovative Solutions in the Treatment of Joint and Ligament Pathologies (TIB PLAT)
In orthopedic surgical practice, there is an increasing incidence of degenerative joint diseases, due to the rising average age of the population, as well as ligament injuries resulting from the growing participation in sports activities. The knee joint, in particular, is the most affected by these conditions, which, given their heterogeneous nature, impact patients across a wide age range.
Knee pathologies, often interconnected (with a higher incidence of degenerative diseases following ligamentous and/or meniscal injuries), are particularly debilitating for patients and entail high costs for the national healthcare system, which are expected to increase over time.
Scientific efforts in the field of knee surgery are therefore focused on achieving an increasingly detailed understanding of pathological conditions, as well as on the development of innovative technologies to support surgical and clinical practice.
Carrying out such analyses and developing new technologies inevitably involves experimental laboratory studies of joint tissues. The study of waste material obtained from surgical procedures represents a fundamental resource in this context and has always been used safely, with no additional invasiveness for the patient. A vast amount of information derived from laboratory analyses of discarded tissue has contributed to improving clinical practice and has led to the development of solutions that are now part of routine surgical use.
Recent technologies allow increasingly accurate evaluation of both the structure and mechanical properties of discarded tissue explanted during surgery. For example, structural assessment using micro-CT enables visualization and analysis of the interface between bone tissue, ligamentous structures, and surgical implants with micrometric precision. This makes it possible to determine tissue density, orientation, and material quality, distinguishing between different boundary conditions and physiopathological states of the tissues. Such analyses can also be performed under conditions close to those characterizing the joint in vivo, both in terms of tissue immersed in fluid and with respect to mechanical loads applied to deform the tissue. Furthermore, it is possible to reconstruct the structural interaction between human tissue and external materials used in surgery, such as screws, plates, anchoring devices, etc.
These instruments therefore make it possible to surpass the level of detail achievable with conventional diagnostic and research equipment used over the years, and to investigate with increasing accuracy the onset and progression of a pathology, the condition of the involved tissues, and to predict functional recovery of the treated site following the application of anchoring devices in the operating room. These new analyses also enable the study of innovative solutions for tissue repair and reconstruction, such as patient-specific customized devices and/or new materials produced using 3D printing technology, without posing any risk to the patient during surgery.
Studie Overzicht
Toestand
Conditie
Studietype
Inschrijving (Werkelijk)
Contacten en locaties
Studie Locaties
-
-
-
Bologna, Italië, 40136
- IRCCS Rizzoli Ortopedic Institute
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
- Volwassen
- Oudere volwassene
Accepteert gezonde vrijwilligers
Bemonsteringsmethode
Studie Bevolking
Beschrijving
Inclusion Criteria:
- Total knee arthroplasty
- Kellgren-Lawrence grade II, III, or IV osteoarthritis;
- age < 85 years;
- BMI < 35
Exclusion Criteria:
- History/evidence of previous partial (unicompartmental) knee arthroplasty;
- positivity for viral infections such as HIV, HBV, or HCV;
- inability to provide informed consent.
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Microstructural properties of the explanted tissue
Tijdsspanne: At least 24 months
|
Porosity of the subchondral bone tissue
|
At least 24 months
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Load transfer mechanisms
Tijdsspanne: At least 24 months
|
Load transfer mechanisms from the residual cartilage tissue to the underlying bone tissue.
Load transfer from the residual cartilage to the subchondral bone can be represented by the stress (Pa) developed in the underlying bone
|
At least 24 months
|
|
Bone/Tissue Density
Tijdsspanne: At least 24 months
|
Tissue density at the anterior cruciate ligament insertion will be quantified using micro-computed tomography and expressed as bone mineral density (mg HA/cm³).
|
At least 24 months
|
|
Structural Organization
Tijdsspanne: At least 24 months
|
Tissue orientation and homogeneity at the ligament insertion will be evaluated using histological and histomorphometric analysis and expressed using quantitative indices (e.g., orientation index, % area uniformity).
|
At least 24 months
|
Medewerkers en onderzoekers
Sponsor
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- TIB PLAT
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .