In Vitro Microstructural and Mechanical Analysis of Waste Material From Total Knee Arthroplasty for the Study of Innovative Solutions in the Treatment of Joint and Ligament Pathologies (TIB PLAT)
In orthopedic surgical practice, there is an increasing incidence of degenerative joint diseases, due to the rising average age of the population, as well as ligament injuries resulting from the growing participation in sports activities. The knee joint, in particular, is the most affected by these conditions, which, given their heterogeneous nature, impact patients across a wide age range.
Knee pathologies, often interconnected (with a higher incidence of degenerative diseases following ligamentous and/or meniscal injuries), are particularly debilitating for patients and entail high costs for the national healthcare system, which are expected to increase over time.
Scientific efforts in the field of knee surgery are therefore focused on achieving an increasingly detailed understanding of pathological conditions, as well as on the development of innovative technologies to support surgical and clinical practice.
Carrying out such analyses and developing new technologies inevitably involves experimental laboratory studies of joint tissues. The study of waste material obtained from surgical procedures represents a fundamental resource in this context and has always been used safely, with no additional invasiveness for the patient. A vast amount of information derived from laboratory analyses of discarded tissue has contributed to improving clinical practice and has led to the development of solutions that are now part of routine surgical use.
Recent technologies allow increasingly accurate evaluation of both the structure and mechanical properties of discarded tissue explanted during surgery. For example, structural assessment using micro-CT enables visualization and analysis of the interface between bone tissue, ligamentous structures, and surgical implants with micrometric precision. This makes it possible to determine tissue density, orientation, and material quality, distinguishing between different boundary conditions and physiopathological states of the tissues. Such analyses can also be performed under conditions close to those characterizing the joint in vivo, both in terms of tissue immersed in fluid and with respect to mechanical loads applied to deform the tissue. Furthermore, it is possible to reconstruct the structural interaction between human tissue and external materials used in surgery, such as screws, plates, anchoring devices, etc.
These instruments therefore make it possible to surpass the level of detail achievable with conventional diagnostic and research equipment used over the years, and to investigate with increasing accuracy the onset and progression of a pathology, the condition of the involved tissues, and to predict functional recovery of the treated site following the application of anchoring devices in the operating room. These new analyses also enable the study of innovative solutions for tissue repair and reconstruction, such as patient-specific customized devices and/or new materials produced using 3D printing technology, without posing any risk to the patient during surgery.
Descripción general del estudio
Estado
Condiciones
Tipo de estudio
Inscripción (Actual)
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
-
Bologna, Italia, 40136
- IRCCS Rizzoli Ortopedic Institute
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
- Adulto
- Adulto Mayor
Acepta Voluntarios Saludables
Método de muestreo
Población de estudio
Descripción
Inclusion Criteria:
- Total knee arthroplasty
- Kellgren-Lawrence grade II, III, or IV osteoarthritis;
- age < 85 years;
- BMI < 35
Exclusion Criteria:
- History/evidence of previous partial (unicompartmental) knee arthroplasty;
- positivity for viral infections such as HIV, HBV, or HCV;
- inability to provide informed consent.
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Microstructural properties of the explanted tissue
Periodo de tiempo: At least 24 months
|
Porosity of the subchondral bone tissue
|
At least 24 months
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Load transfer mechanisms
Periodo de tiempo: At least 24 months
|
Load transfer mechanisms from the residual cartilage tissue to the underlying bone tissue.
Load transfer from the residual cartilage to the subchondral bone can be represented by the stress (Pa) developed in the underlying bone
|
At least 24 months
|
|
Bone/Tissue Density
Periodo de tiempo: At least 24 months
|
Tissue density at the anterior cruciate ligament insertion will be quantified using micro-computed tomography and expressed as bone mineral density (mg HA/cm³).
|
At least 24 months
|
|
Structural Organization
Periodo de tiempo: At least 24 months
|
Tissue orientation and homogeneity at the ligament insertion will be evaluated using histological and histomorphometric analysis and expressed using quantitative indices (e.g., orientation index, % area uniformity).
|
At least 24 months
|
Colaboradores e Investigadores
Patrocinador
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Actual)
Finalización del estudio (Actual)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- TIB PLAT
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .