Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

In Vitro Microstructural and Mechanical Analysis of Waste Material From Total Knee Arthroplasty for the Study of Innovative Solutions in the Treatment of Joint and Ligament Pathologies (TIB PLAT)

30 avril 2026 mis à jour par: Stefano Zaffagnini

In orthopedic surgical practice, there is an increasing incidence of degenerative joint diseases, due to the rising average age of the population, as well as ligament injuries resulting from the growing participation in sports activities. The knee joint, in particular, is the most affected by these conditions, which, given their heterogeneous nature, impact patients across a wide age range.

Knee pathologies, often interconnected (with a higher incidence of degenerative diseases following ligamentous and/or meniscal injuries), are particularly debilitating for patients and entail high costs for the national healthcare system, which are expected to increase over time.

Scientific efforts in the field of knee surgery are therefore focused on achieving an increasingly detailed understanding of pathological conditions, as well as on the development of innovative technologies to support surgical and clinical practice.

Carrying out such analyses and developing new technologies inevitably involves experimental laboratory studies of joint tissues. The study of waste material obtained from surgical procedures represents a fundamental resource in this context and has always been used safely, with no additional invasiveness for the patient. A vast amount of information derived from laboratory analyses of discarded tissue has contributed to improving clinical practice and has led to the development of solutions that are now part of routine surgical use.

Recent technologies allow increasingly accurate evaluation of both the structure and mechanical properties of discarded tissue explanted during surgery. For example, structural assessment using micro-CT enables visualization and analysis of the interface between bone tissue, ligamentous structures, and surgical implants with micrometric precision. This makes it possible to determine tissue density, orientation, and material quality, distinguishing between different boundary conditions and physiopathological states of the tissues. Such analyses can also be performed under conditions close to those characterizing the joint in vivo, both in terms of tissue immersed in fluid and with respect to mechanical loads applied to deform the tissue. Furthermore, it is possible to reconstruct the structural interaction between human tissue and external materials used in surgery, such as screws, plates, anchoring devices, etc.

These instruments therefore make it possible to surpass the level of detail achievable with conventional diagnostic and research equipment used over the years, and to investigate with increasing accuracy the onset and progression of a pathology, the condition of the involved tissues, and to predict functional recovery of the treated site following the application of anchoring devices in the operating room. These new analyses also enable the study of innovative solutions for tissue repair and reconstruction, such as patient-specific customized devices and/or new materials produced using 3D printing technology, without posing any risk to the patient during surgery.

Aperçu de l'étude

Statut

Complété

Type d'étude

Observationnel

Inscription (Réel)

29

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

      • Bologna, Italie, 40136
        • IRCCS Rizzoli Ortopedic Institute

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Adulte
  • Adulte plus âgé

Accepte les volontaires sains

Non

Méthode d'échantillonnage

Échantillon non probabiliste

Population étudiée

Waste materials obtained from primary total knee arthroplasty procedures will be used. The collected material will mainly consist of osteochondral tissue from the patient's tibial plateau. This portion of tissue is routinely removed during the resection of the proximal (tibia) and distal (femur) bone components, which is necessary for the implantation of the prosthetic components. The resection and subsequent removal of the tibial plateau constitute a standard procedure and a mandatory step in primary total knee arthroplasty. This procedure will be performed intraoperatively by the medical staff of the coordinating investigator (Orthopaedic and Traumatology Clinic II). The waste material will be placed in a dedicated single-use container and transferred to the Research Center laboratories for analysis, in accordance with the above-mentioned internal procedure.

La description

Inclusion Criteria:

  • Total knee arthroplasty
  • Kellgren-Lawrence grade II, III, or IV osteoarthritis;
  • age < 85 years;
  • BMI < 35

Exclusion Criteria:

  • History/evidence of previous partial (unicompartmental) knee arthroplasty;
  • positivity for viral infections such as HIV, HBV, or HCV;
  • inability to provide informed consent.

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Microstructural properties of the explanted tissue
Délai: At least 24 months
Porosity of the subchondral bone tissue
At least 24 months

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Load transfer mechanisms
Délai: At least 24 months
Load transfer mechanisms from the residual cartilage tissue to the underlying bone tissue. Load transfer from the residual cartilage to the subchondral bone can be represented by the stress (Pa) developed in the underlying bone
At least 24 months
Bone/Tissue Density
Délai: At least 24 months
Tissue density at the anterior cruciate ligament insertion will be quantified using micro-computed tomography and expressed as bone mineral density (mg HA/cm³).
At least 24 months
Structural Organization
Délai: At least 24 months
Tissue orientation and homogeneity at the ligament insertion will be evaluated using histological and histomorphometric analysis and expressed using quantitative indices (e.g., orientation index, % area uniformity).
At least 24 months

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Parrainer

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

30 novembre 2021

Achèvement primaire (Réel)

7 mars 2024

Achèvement de l'étude (Réel)

7 janvier 2025

Dates d'inscription aux études

Première soumission

21 avril 2026

Première soumission répondant aux critères de contrôle qualité

30 avril 2026

Première publication (Réel)

6 mai 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

6 mai 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

30 avril 2026

Dernière vérification

1 avril 2026

Plus d'information

Termes liés à cette étude

Termes MeSH pertinents supplémentaires

Autres numéros d'identification d'étude

  • TIB PLAT

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner