Self-Centering Guide Catheter Feasibility Study
August 27, 2018 updated by: Boston Scientific Corporation
An evaluation of the feasibility of using the Self-Centering Guide Catheter to deliver a guide wire across a stenotic native aortic valve into the left ventricle.
Study Overview
Status
Completed
Conditions
Intervention / Treatment
Detailed Description
A prospective, open-label, single-arm feasibility study evaluating the Self-Centering Guide Catheter.
All subjects who are candidates for transcatheter aortic valve replacement (TAVR) of a native valve with a transcatheter aortic valve that is introduced percutaneously via the femoral artery using conventional catheterization techniques will be evaluated for enrollment in this study.
The Self-Centering Guide Catheter is intended to facilitate delivery of a guidewire across a stenotic native aortic valve and into the left ventricle.
Study Type
Interventional
Enrollment (Actual)
20
Phase
- Not Applicable
Contacts and Locations
This section provides the contact details for those conducting the study, and information on where this study is being conducted.
Study Locations
-
-
Minnesota
-
Rochester, Minnesota, United States, 55905
- Mayo Clinic
-
-
Participation Criteria
Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.
Eligibility Criteria
Ages Eligible for Study
18 years to 110 years (Adult, Older Adult)
Accepts Healthy Volunteers
No
Genders Eligible for Study
All
Description
Inclusion Criteria:
- Subject must be at least 18 years of age.
- Subject (or legal guardian) understands the study requirements and the treatment procedures and provides written informed consent before any study-specific tests or procedures are performed.
- Subject is eligible for and is an acceptable candidate for transcatheter aortic valve replacement of a stenotic (aortic valve area ≤1 cm2, aortic jet velocity ≥4.0 m/s, or mean gradient ≥40 mmHg) native valve with a transcatheter aortic valve that is introduced percutaneously via the femoral artery using conventional catheterization techniques.
Exclusion Criteria:
- Subject has known hypersensitivity to the components of the device (e.g., polyether block amide, fluoropolymers, nickel, platinum, tantalum, titanium).
- Subject has a pre-existing prosthetic aortic valve.
Study Plan
This section provides details of the study plan, including how the study is designed and what the study is measuring.
How is the study designed?
Design Details
- Primary Purpose: Device Feasibility
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Experimental: Self-Centering Guide Catheter
Subjects who provided written informed consent and an attempt is made to insert the Self-Centering Guide Catheter into the subject's femoral artery.
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Number of Self-Centering Guide Catheters Successfully Used to Deliver a Guide Wire Through the Self-Centering Guide Catheter Across the Stenotic Native Aortic Valve Into the Left Ventricle
Time Frame: Through study completion, up to 72 hours post-procedure
|
This outcome will be assessed via physician determination and will be recorded in the case report form.
|
Through study completion, up to 72 hours post-procedure
|
Other Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Time From Insertion of the Self-Centering Guide Catheter Into the Body to Successful Placement of a PTFE-coated Guidewire Across the Stenotic Native Aortic Valve
Time Frame: Through study completion, up to 72 hours post-procedure
|
Through study completion, up to 72 hours post-procedure
|
|
|
Time From Insertion of the Self-Centering Guide Catheter Into the Body to Removal of the Self-Centering Guide Catheter From the Body
Time Frame: Through study completion, up to 72 hours post-procedure
|
Through study completion, up to 72 hours post-procedure
|
|
|
Number of Attempts Made to Cross the Stenotic Native Aortic Valve With a PTFE-coated Guidewire
Time Frame: Through study completion, up to 72 hours post-procedure
|
Through study completion, up to 72 hours post-procedure
|
|
|
Successful Recapture of the Distal Self-centering Basket of the Device Into the Guide and Withdrawal of the Self-Centering Guide Catheter Through the Guide System
Time Frame: Through study completion, up to 72 hours post-procedure
|
The outcome measure of successful recapture of the distal self-centering basket of the device into the guide and withdrawal of the Self-Centering Guide Catheter through the guide system will be assessed via physician assessment of the self-centering basket recapture and will be recorded in the case report form.
|
Through study completion, up to 72 hours post-procedure
|
|
Number of Self-Centering Guide Catheters With Device Success
Time Frame: Through study completion, up to 72 hours post-procedure
|
Device success is defined as successful delivery of a guide wire through the Self-Centering Guide Catheter across the stenotic native aortic valve into the left ventricle and successful recapture of the distal self-centering basket of the device into the guide and withdrawal of the Self-Centering Guide Catheter through the guide system.
This outcome will be assessed via physician determination and will be recorded in the case report form.
|
Through study completion, up to 72 hours post-procedure
|
|
Number of Participants With Stroke
Time Frame: 72 hours post-procedure
|
72 hours post-procedure
|
|
|
Number of Participants With Cardiac Tamponade
Time Frame: 72 hours post-procedure
|
72 hours post-procedure
|
|
|
Death, All-cause, Cardiovascular, and Non-cardiovascular
Time Frame: 72 hours post-procedure
|
72 hours post-procedure
|
|
|
Any Device-related Adverse Event
Time Frame: 72 hours post-procedure
|
72 hours post-procedure
|
|
|
Any Adverse Event Occurring While the Self-Centering Guide Catheter is in the Subject
Time Frame: 72 hours post-procedure
|
72 hours post-procedure
|
|
|
Number of Device Deficiencies Including But Not Limited to Failures, Malfunctions, Use Errors, Product Nonconformities, and Labeling Errors
Time Frame: 72 hours post-procedure
|
All device deficiencies including but not limited to failures, malfunctions, use errors, product nonconformities, and labeling errors will be recorded in the case report form
|
72 hours post-procedure
|
Collaborators and Investigators
This is where you will find people and organizations involved with this study.
Sponsor
Investigators
- Principal Investigator: Rajiv Gulati, MD, PhD, Mayo Clinic
Study record dates
These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.
Study Major Dates
Study Start (Actual)
May 12, 2016
Primary Completion (Actual)
October 6, 2016
Study Completion (Actual)
October 6, 2016
Study Registration Dates
First Submitted
December 17, 2015
First Submitted That Met QC Criteria
December 21, 2015
First Posted (Estimate)
December 24, 2015
Study Record Updates
Last Update Posted (Actual)
August 29, 2018
Last Update Submitted That Met QC Criteria
August 27, 2018
Last Verified
August 1, 2018
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- S2360
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
NO
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
No
Studies a U.S. FDA-regulated device product
Yes
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Aortic Stenosis
-
National Institute of Cardiology, Warsaw, PolandThe Institute of Bioorganic Chemistry, Polish Academy of SciencesRecruitingAortic Stenosis | Low-gradient Aortic StenosisPoland
-
MiRusRecruitingAortic Stenosis | Symptomatic Severe Native Aortic StenosisUnited States
-
Edwards LifesciencesCompletedAortic Stenosis | Aortic Regurgitation | Symptomatic Aortic StenosisChina
-
Anteris Technologies Ltd.Active, not recruitingAortic Stenosis | Aortic Valve Calcification | Severe Aortic Valve Stenosis | Symptomatic Aortic StenosisUnited States
-
Azienda Ospedaliera "Sant'Andrea"University of Bologna; Politecnico di Milano; Centro Cardiologico Monzino; I.R.C...RecruitingAortic Stenosis | Calcific Aortic Valve Disease | Chronic Coronary Syndrome | Calcific Aortic StenosisItaly
-
Hospices Civils de LyonCompleted
-
Abbott Medical DevicesCompletedSevere Aortic Stenosis | Symptomatic Degenerative Aortic StenosisSpain, Italy, United Kingdom, Germany, Switzerland, Czechia, Australia, Belgium, Poland
-
Edwards LifesciencesRecruitingAortic Valve Stenosis | Aortic Stenosis, CalcificUnited States, Australia, Switzerland, Canada, Japan, Netherlands
-
University of AlbertaNot yet recruitingAortic Stenosis | Severe Aortic StenosisCanada
-
Medtronic CardiovascularCompleted
Clinical Trials on Self-Centering Guide Catheter
-
University Hospital HeidelbergCompletedAcute Ischemic Stroke | Acute Ischemic Stroke AIS | Acute Ischemic Stroke PatientsGermany
-
Capital Medical UniversityUnknownStroke | Mechanical Thrombectomy | Balloon Guide CatheterChina
-
Tallahassee Research Institute, Inc.Boston Scientific CorporationCompleted
-
Second Affiliated Hospital, School of Medicine,...Recruiting
-
Changhai HospitalTerminatedThrombosis | Acute Ischemic Stroke | Large Vessel Occlusion | ThrombectomyChina
-
University of South FloridaRecruitingAcute Ischemic Stroke AISUnited States
-
Tianjin Demax Medical Technology Co., LtdCEISONot yet recruitingCoronary Artery DiseaseFrance
-
University Hospital, MontpellierRecruitingIntensive Care | Newborns | NeonatologyFrance
-
King's College LondonGuy's and St Thomas' NHS Foundation Trust; South London and Maudsley NHS Foundation...CompletedAnxiety | Autism Spectrum DisordersUnited Kingdom
-
Xuanwu Hospital, BeijingFujian Medical University Union Hospital; Zhangzhou Affiliated Hospital of...Recruiting