- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT03831087
Cardiac Magnetic Resonance Imaging Versus Computed Tomography to Guide Transcatheter Aortic Valve Replacement (TAVR-CMR)
Cardiac Magnetic Resonance Imaging Versus Computed Tomography to Guide Transcatheter Aortic Valve Replacement: A Randomized Multicenter Trial
Study Overview
Status
Conditions
Intervention / Treatment
Detailed Description
Study Title: Cardiac Magnetic Resonance Imaging Versus Computed Tomography to Guide Transcatheter Aortic Valve Replacement (TAVR-CMR).
Coordinating Prinicpal Investigator: Prof. Bernhard Metzler, University Clinic of Internal Medicine III, Cardiology and Angiology, Innsbruck Medical University.
Planned Study Period: 2017-2023.
Objective: To investigate, for the first time, the non-inferiority of TAVR-CMR to contrast-enhanced computed tomography (TAVR-CT) regarding efficacy and safety end-points.
Design: Prospective, randomized, open-label, multi-centre trial.
Patients (planned): 270 patients.
Diagnosis / Inclusion Criteria: Symptomatic severe aortic stenosis scheduled for TAVR based on a local heart-team decision.
Methods: Patients will be randomized in a 1:1 fashion to receive a predefined TAVR-CMR protocol or to receive a standard TAVR-CT protocol within two weeks after inclusion.
Main Outcome Measure: Follow-up will be performed at hospital discharge after TAVR and after 6 months. The primary efficacy outcome is device implantation success at discharge. The secondary endpoints are a combined safety endpoint and a combined clinical efficacy endpoint at baseline and at 6 months, as well as a comparison of imaging procedure related variables (see section 5.11.2). Endpoint definitions are based on the updated 2012 VARC-2 consensus document.
Study Type
Enrollment (Actual)
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Tirol
-
Innsbruck, Tirol, Austria, 6020
- University Clinic of Internal Medicine III
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Signed informed consent
- Severe aortic stenosis according to recent guidelines (aortic valve area ≤ 1.0cm² or aortic valve index ≤ 0.6 cm²/m²) (1)
- Typical symptoms of severe aortic stenosis like shortness of breath, angina or syncope
- Patient is evaluated for TAVR
Exclusion Criteria:
- Contraindications to perform CMR
- Contraindications to perform CT
- Contraindications for TAVR or reduced life expectancy < 1 year.
- Known hypersensitivity to CMR or CT contrast agents
- Childbearing potential or inability to exclude pregnancy
- Inability to understand and follow study-related instructions
- Severe renal insufficiency requiring renal replacement therapy
- Severe hepatic insufficiency (Child-Pugh class B or C)
- Post organ transplantation
- Participation in another clinical study
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Other: TAVR-CMR
All MR examinations will be performed with a 1.5-T clinical MR imaging unit (AVANTO_fit; Siemens, Erlangen, Germany).
The MR protocol consists of a Navigator-gated free breathing 3D "whole-heart" coronary magnetic resonance angiography (MRA), axial 2D true fast imaging with steady-state free precession (true-FISP) during free breathing covering whole body trunk and a coronal 3D fast low-angle shot (FLASH) Gd-MRA.
|
CMR protocol for the exact determination of the aortic valve dimensions, valve size and implantation route.
|
|
Other: TAVR-CT
All CT examinations will be performed on a 128-slice dual-source CT and high-pitch factor.
Prospective electrocardiographic synchronization will be applied, triggered into the diastolic phase for the heart.
An injected bolus of 70 to 110 mL of nonionic iodine contrast agent will be applied with 370 mg/mL iodine concentration, using an automatic injector at a flow rate of 5 mL/s, followed by 40 mL saline solution.
Contrast agent volume for each patient will be calculated by scan time and body weight.
Patients will be placed supine with arms overhead.
The scan length range from supraaortic branches to the groins.
|
CT protocol for the exact determination of the aortic valve dimensions, valve size and implantation route.
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
The non-inferiority of TAVR-CMR compared to TAVR-CT to guide TAVR according to clinical efficacy, defined as implantation success based on the VARC-2 criteria.
Time Frame: 6 months
|
The primary outcome will be a composite clinical efficacy end-point related to implantation success at hospital discharge, based on the VARC-2 criteria: Absence of procedural mortality AND correct positioning of the prosthetic valve AND intended performance of the prosthetic valve (mean aortic valve gradient < 20mmHg and no valve regurgitation > mild)
|
6 months
|
Collaborators and Investigators
Sponsor
Investigators
- Principal Investigator: Bernhard Metzler, Prof., Medical University Innsbruck
Publications and helpful links
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- 20171002-1653
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Aortic Stenosis
-
MiRusRecruitingAortic Stenosis | Symptomatic Severe Native Aortic StenosisUnited States
-
National Institute of Cardiology, Warsaw, PolandThe Institute of Bioorganic Chemistry, Polish Academy of SciencesRecruitingAortic Stenosis | Low-gradient Aortic StenosisPoland
-
Edwards LifesciencesCompletedAortic Stenosis | Aortic Regurgitation | Symptomatic Aortic StenosisChina
-
Azienda Ospedaliera "Sant'Andrea"University of Bologna; Politecnico di Milano; Centro Cardiologico Monzino; I.R.C...RecruitingAortic Stenosis | Calcific Aortic Valve Disease | Chronic Coronary Syndrome | Calcific Aortic StenosisItaly
-
Anteris Technologies Ltd.Active, not recruitingAortic Stenosis | Aortic Valve Calcification | Severe Aortic Valve Stenosis | Symptomatic Aortic StenosisUnited States
-
Abbott Medical DevicesCompletedSevere Aortic Stenosis | Symptomatic Degenerative Aortic StenosisSpain, Italy, United Kingdom, Germany, Switzerland, Czechia, Australia, Belgium, Poland
-
Hospices Civils de LyonCompleted
-
Edwards LifesciencesRecruitingAortic Valve Stenosis | Aortic Stenosis, CalcificUnited States, Australia, Switzerland, Canada, Japan, Netherlands
-
University of AlbertaNot yet recruitingAortic Stenosis | Severe Aortic StenosisCanada
-
Medtronic CardiovascularCompleted
Clinical Trials on TAVR-CMR
-
MiRusRecruitingAortic Stenosis | Symptomatic Severe Native Aortic StenosisUnited States
-
Niguarda HospitalRecruitingAortic Valve Stenosis | Transcatheter Aortic Valve ReplacementItaly
-
Zhicheng Medical Technology (Jiaxing) Co, LtdBeijing Anzhen Hospital; Second Xiangya Hospital of Central South University; Fu Wai Hospital, Beijing, China and other collaboratorsNot yet recruitingAortic Stenosis Treated With TAVI
-
Region StockholmRecruitingAcute Coronary Syndrome | Non-ST Elevation Myocardial InfarctionSweden
-
Abbott Medical DevicesCompletedAortic Valve StenosisGermany, Netherlands, Italy, Switzerland, Denmark
-
Edwards LifesciencesCompletedSymptomatic Severe Aortic StenosisUnited States
-
IRCCS Policlinico S. DonatoCompletedFailed Transcather Aortic ValveItaly
-
University of UlmCompletedPM Implantation After TAVRGermany
-
Michele De BonisCompletedAortic StenosisDenmark, Hungary, Italy
-
Edwards LifesciencesAmerican College of CardiologyCompletedCalcific Aortic Stenosis | Severe | SymptomaticUnited States