- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT03864120
Understand the Difference Between Clinical Measured UF and Real UF.
Understand the Difference Between Clinical Measured Ultrafiltration and Real Ultrafiltration.
The importance of ultrafiltration (UF) and fluid status in peritoneal dialysis has been increasingly aware of over the last two decades. There is growing body of observational evidence showing that low UF is related to unfavorable outcome especially in anuric patients. The other side of the problem of UF is excessive fluid removal could volume deplete patients and result in loss of residual renal function and overexposing the membrane to glucose unnecessarily. UF is a double-edged sword. The correct measure of UF is the bottom line of talking about target.
Measuring UF is supposed to be simple and straight forward. The most common way of measuring UF in clinical practice was to weight the effluent bag and minus the manufacture announced fill volume.
Until about 10 years ago, the society first aware that the measurement error in such way is not acceptable. Overfil (the actual volume of dialysate fill in the bag is more than announced) problem was raised from then.
However, there are several other problems around this issue. Firstly, when the product has just been produced overfill is different between manufactory.
Secondly, the overfill volume does change over transportation and storage. But it is not clear how big the change is.
Thirdly, most of the clinics weight the dialysate effluent rather than measure the volume in CAPD, although the specific gravity of dialysate is clearly not going to be 1g/ml.
Taking the fact measuring weight is much easier than measuring volume in CAPD, the question behind is to understand how big the difference is and consequently whether it is acceptable.
All the patients enrolled in the study would be asked to collect all dialysate effluent of the day of their routine peritoneal dialysis adequacy study and bring to the hospital. The exact weight of the bag for PET test (2.5% glucose concentration and dwell time of 4 hour) before and after the dwell and volume measured of the effluent. The dialysate electrolyte, glucose, protein and creatinine level would also be measured.
Study Overview
Status
Conditions
Study Type
Enrollment (Actual)
Contacts and Locations
Study Locations
-
-
Shanghai
-
Shanghai, Shanghai, China
- RenJi Hospital
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
Inclusion Criteria:
- Age >18 years
- on PD treatment for at least one month
- signed the consent
Exclusion Criteria:
- Peritonitis or recovery from peritonitis for less than one month.
- On any intra peritoneal treatment apart from peritoneal dialysis.
- Evidence of decompensated liver cirrhosis or heart failure.
- Evidence of extra peritoneal leakage, eg. leakage to thoracic cavity, post peritoneal, hernia.
Study Plan
How is the study designed?
Design Details
- Observational Models: Case-Only
- Time Perspectives: Cross-Sectional
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
specific gravity of effluent dialysate is different from water (1g/ml)
Time Frame: For each patient, the outcome would be cross sectional measured at the time the patient does his 6 monthly routine PET test. The data collection time period of the study is 6 month.
|
To describe the specific gravity of effluent dialysate, the exact weight and volume of effluent dialysate bags in the standard peritoneal equivalent test (PET, 2.5% glucose concentration, 2L, dwell time 4 hours) dwell would be measured in different patients.
|
For each patient, the outcome would be cross sectional measured at the time the patient does his 6 monthly routine PET test. The data collection time period of the study is 6 month.
|
Collaborators and Investigators
Sponsor
Investigators
- Principal Investigator: Zanzhe Yu, MD, RenJi Hospital
Publications and helpful links
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
- 仁济2018(078)
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.