Observational Study on the Preparation of the Implant Site With Piezosurgery vs Drill: Comparison Between the Two Methods in Terms of Post-operative Pain, Surgical Times and Operational Advantages

June 5, 2019 updated by: Bevilacqua Lorenzo, University of Trieste

Purpose: Recent advances showed that ultrasonic implant site osteotomy is related with a decreased trauma and a better post operative healing of the surgical site if compared to the traditional drilling techniques. The micrometric bone cutting control and the operative advantages related to the piezoelectric approach is also characterized by a learning curve for the clinician in surgical practice and an increased operative duration of the procedure. The aim of this investigation was to compare the operative time, the post operative pain and the patients frequency of intake of painkillers in the healing period.

Methods: A total of 75 patients were treated at the Unit of Oral Surgery (Department of Medical Sciences, Surgery and Health, University of Trieste, Italy) in a split mouth model: 75 drill-inserted implants (G1) and 75 piezoelectric device- inserted implants (G2). The Visual Analogue Scale (VAS) was performed to evaluate the post-operative pain at 15 days from the surgery. The operative time and frequency of intake of painkillers was measured.

Study Overview

Detailed Description

Materials and Methods The study was conducted after the approval of the local ethical Comettee (n. 88-10.05.2018) University of Trieste.

The following study took into account adult patients undergoing implant therapy with insertion of two contralateral conical implants with a diameter between 3.8 and 4.5 mm with a maximum torque of 35 Ncm. One site was prepared with Ultrasonic device (Esacrom, Imola, Italy) while the contralateral was prepared with micromotor and dedicated drills. All patients were treated at the Unit of Oral Surgery (Department of Medical Sciences, Surgery and Health, University of Trieste, Italy). Seventy-five patients were enrolled in the study, 44 women and 31 men, aged between 45 and 70, who underwent implant therapy in the period between January 2013 and December 2017. The inclusion criteria were: edentulous or partly edentulous with a bilateral loss of teeth in the maxillary or mandible and bone type D2 or D3, following Misch classification16.

The exclusion criteria included: general contraindications to implant surgery, severe coagulation disorders, leukocyte or metabolic diseases, immunosuppressed or immunocompromised patients, patients receiving chemotherapy for less than 1 year, patients on therapy or having taken amino- bisphosphonates intravenously, patients irradiated to the head or neck, patients with uncontrolled diabetes, pregnant and lactating patients, patients with poor oral hygiene and motivation, patients needing maxillary sinus lift concomitant with implant insertion, post-extraction sites with acute or purulent infections.

The final sample of the implants inserted was 150 (75 per technique) then identifying two dependent groups: the drill-inserted implants (G1) and the ultrasonic device- inserted implants (G2). Each patient subscribed an informed written consent and underwent a pre-operative oral hygiene session. Two grams of Amoxicillin were administered to each patient in the preoperative phase. Before surgery, each patient made a rinse with a 0.2% chlorhexidine mouthwash for one minute. The surgery was always performed by the same operator (M.M.) to reduce the bias of the study. Loco-regional anesthesia was performed with Mepivacaine hydrochloride with 1:100000 adrenaline.

For the preparation of implant sites using traditional methods, the drills were used following manufacturer's protocol by the implant system in use (WINSIX®- BioSAF IN s.r.l, Trezzano Rosa, Trezzano Rosa, Milano - Italy).

For the preparation of sites was used ultrasonic device, (Surgysonic II, Esacrom S.r.l., Imola, Italy). For the final preparation and insertion of implants, 5-6 ultrasound inserts were used in sequence as follows: tip-shape 1st insert (ES012X) and 2nd insert (ES052XG), crown-shape 3rd insert (ES040), 4th insert (ES041), 5 ° insert (ES043) and 6th insert (ES044).

The implant insertion was performed with a maximum torque of 35 Ncm. Finally, the cap screws were positioned, and the flaps were sutured in Vycril® 3.0.

Each patient was prescribed a 0.2% chlorhexidine mouthwash to be used twice a day for two weeks and paracetamol 1000 mg (maximum 3 tablets a day) as a pain-relieving therapy.

Each patient included in the study was therefore in possession of two questionnaires, one per technique, for the evaluation of the treatment. In the questionnaire the patient was asked to trace an "X" representing the level of pain experienced. The questionnaire recorded the individual symptoms experienced during the surgery, after 8 hours, from the 1st to the 7th day and finally any persistence

of the symptoms on the 15th day after surgery. In the same questionnaire was also asked to indicate the possible intake of painkillers and the related dose, after surgery and in the following six days; moreover, after the fifteenth day, the patient was asked if he have repeated the experience of the implant surgery. Then, for each patient, a postoperative check was scheduled: after one week all the patients were recalled for a post-operative control and the removal of the sutures.

For the subjective analysis of the effects of the two methods, it was decided to use the Visual Analogue Scale (VAS). This linear scale is the visual representation of the amplitude of pain that the patient perceives. It is a horizontal line 100 mm long, in which one end indicates the absence of pain, while the other represents the worst pain imaginable.

During the surgical procedure the preparation times of the implant site were measured from the preparation of the flap up to the insertion of the implant.

Immediately after the end of the surgical procedure, a questionnaire on the operative difficulty was compiled by the operator. In particular, the two techniques were compared considering two factors: the easiness in obtaining a correct axis of implants insertion and the quality of visibility. Furthermore, a cumulative judgement has been done for the whole procedure, as "simple", "of medium difficulty", "difficult".

Statistical Analysis SPSS software (SPSS Inc. Chicago, IL) was used for statistical analysis. A value of p <0.05 was used in rejecting the null hypothesis.

In addition, continuous data were analyzed using non-parametric tests given the asymmetric distribution of some data sets.

Friedman test was used to evaluate the significance of VAS differences within groups over time. Wilcoxon test was used to evaluate the significance of VAS differences within groups and between groups at each time point.

A Cochrane test was used to assess the significance of differences in the frequency of intake of painkillers within groups over time. Subsequently, a McNemar test was used for post-hoc analysis and to assess the significance of differences in the frequency of intake of painkillers between groups each time point.

After having calculated the mean operative times for G1 and G2 Mann-Whitney test was used to compare the differences in surgical times between D2 and D3 bone type within each group while Wilcoxon test was used to intercept the differences between groups in bone type D2 and D3, respectively.

The same McNemar test was used to test the differences in the operator questionnaire answers between groups.

Study Type

Observational

Enrollment (Actual)

75

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • Italy, Trieste
      • Trieste, Italy, Trieste, Italy, 34127
        • Department of Medical Sciences, University of Trieste

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

45 years to 70 years (ADULT, OLDER_ADULT)

Accepts Healthy Volunteers

Yes

Genders Eligible for Study

All

Sampling Method

Non-Probability Sample

Study Population

. Seventy-five patients were enrolled in the study, 44 women and 31 men, aged between 45 and 70

Description

Inclusion Criteria:

  • edentulous or partly edentulous with a bilateral loss of teeth in the maxillary or mandible
  • bone type D2 or D3, following Misch classification

Exclusion Criteria:

  • general contraindications to implant surgery
  • severe coagulation disorders
  • immunosuppressed or immunocompromised patients
  • patients receiving chemotherapy for less than 1 year
  • patients on therapy or having taken amino-bisphosphonates intravenously
  • patients irradiated to the head or neck
  • patients with uncontrolled diabetes
  • pregnant and lactating patients
  • patients with poor oral hygiene and motivation
  • patients needing maxillary sinus lift concomitant with implant insertion
  • post-extraction sites with acute or purulent infections.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

Cohorts and Interventions

Group / Cohort
Intervention / Treatment
the drill-inserted implants (G1)

The surgery was always performed by the same operator (M.M.) to reduce the bias of the study. Loco-regional anesthesia was performed with Mepivacaine hydrochloride with 1:100000 adrenaline.

For the preparation of implant sites using traditional methods, the drills were used following manufacturer's protocol by the implant system in use (WINSIX®- BioSAF IN s.r.l, Trezzano Rosa, Trezzano Rosa, Milano - Italy).

For the preparation of sites was used ultrasonic device, (Surgysonic II, Esacrom S.r.l., Imola, Italy). For the final preparation and insertion of implants, 5-6 ultrasound inserts were used in sequence as follows: tip-shape 1st insert (ES012X) and 2nd insert (ES052XG), crown-shape 3rd insert (ES040), 4th insert (ES041), 5 ° insert (ES043) and 6th insert (ES044).

The implant insertion was performed with a maximum torque of 35 Ncm. Finally, the cap screws were positioned, and the flaps were sutured in Vycril® 3.0.

the ultrasonic device- inserted implants (G2)

The surgery was always performed by the same operator (M.M.) to reduce the bias of the study. Loco-regional anesthesia was performed with Mepivacaine hydrochloride with 1:100000 adrenaline.

For the preparation of implant sites using traditional methods, the drills were used following manufacturer's protocol by the implant system in use (WINSIX®- BioSAF IN s.r.l, Trezzano Rosa, Trezzano Rosa, Milano - Italy).

For the preparation of sites was used ultrasonic device, (Surgysonic II, Esacrom S.r.l., Imola, Italy). For the final preparation and insertion of implants, 5-6 ultrasound inserts were used in sequence as follows: tip-shape 1st insert (ES012X) and 2nd insert (ES052XG), crown-shape 3rd insert (ES040), 4th insert (ES041), 5 ° insert (ES043) and 6th insert (ES044).

The implant insertion was performed with a maximum torque of 35 Ncm. Finally, the cap screws were positioned, and the flaps were sutured in Vycril® 3.0.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Time Frame
level of pain experienced
Time Frame: 1.1.2013-31.12.2017
1.1.2013-31.12.2017

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (ACTUAL)

January 1, 2013

Primary Completion (ACTUAL)

December 31, 2017

Study Completion (ACTUAL)

December 31, 2017

Study Registration Dates

First Submitted

June 3, 2019

First Submitted That Met QC Criteria

June 5, 2019

First Posted (ACTUAL)

June 7, 2019

Study Record Updates

Last Update Posted (ACTUAL)

June 7, 2019

Last Update Submitted That Met QC Criteria

June 5, 2019

Last Verified

June 1, 2019

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Preparation of the Implant Site With Piezosurgery vs Drill

Clinical Trials on preparation of the implant site with Piezosurgery vs drill

3
Subscribe