Performance of the Poseidon System for Fluid Management During Water-aided Colonoscopy
August 29, 2022 updated by: WAE Medical
A Prospective, Pre-Market, Multicenter, Non-significant Risk Study to Validate the Performance of the Poseidon System for Fluid Management During Water-aided Colonoscopy
To validate the performance of the Poseidon System™ for fluid management during water-aided endoscopic procedures in the colon.
Study Overview
Status
Not yet recruiting
Conditions
Intervention / Treatment
Detailed Description
The Poseidon System is a fluid management system that is investigationally indicated to provide a pathway to control waste fluid during irrigation of the colon.
The Poseidon device is a manually placed and controlled device that provides support and sealing on the perimeter of an endoscope while managing fluids naturally exiting the anus, during a colonoscopy procedure.
The device consists of a introducer and hand piece that allows for passage of an endoscope with valves and a retention balloon that minimize fluid passage with a single-use waste bag for collecting fluid and debris.
The Poseidon™ System is not yet FDA 510(k) cleared.
Study Type
Interventional
Enrollment (Anticipated)
30
Phase
- Not Applicable
Contacts and Locations
This section provides the contact details for those conducting the study, and information on where this study is being conducted.
Study Locations
-
-
California
-
San Francisco, California, United States, 94109
- Sutter Health - 1101 Van Ness Ave
-
Contact:
- Laura Nguyen
- Email: Laura.Nguyen@sutterhealth.org
-
-
Participation Criteria
Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.
Eligibility Criteria
Ages Eligible for Study
18 years and older (Adult, Older Adult)
Accepts Healthy Volunteers
No
Genders Eligible for Study
All
Description
Inclusion Criteria:
- Patients 18 years of age or greater.
- Patients that have an indication to undergo water-aided colonoscopy.
- Subjects with the ability to understand the requirements of the study, who have provided written informed consent, and who are willing and able to return for the required follow-up assessments.
Exclusion Criteria:
- Subject unable or unwilling to provide informed consent.
- Subjects with prolapsing hemorrhoids that require intervention or hemorrhoids that have been treated within last 3 months.
- Prior TAMIS (Trans-anal minimally invasive surgery) or TEMS (Trans-anal micro endoscopic surgery).
- Any condition that in the opinion of the Investigator would create an unsafe clinical situation that would not allow the patient to safely undergo an endoscopic procedure.
- Pregnant or lactating women or women of childbearing potential who do not employ a reliable method of contraception as judged by the Investigator, and/or are not willing to use reliable contraception for the duration of study participation.
- Patient is enrolled in another trial that could interfere with the endpoint analyses of this trial.
Study Plan
This section provides details of the study plan, including how the study is designed and what the study is measuring.
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Experimental: Feasibility Assessment
The Poseidon System is investigational and indicated to provide a pathway to control waste fluid during irrigation of the colon.
All consented patients will receive the Device use during their colonoscopy procedure.
|
To validate the performance of the Poseidon System™ for fluid management during water-aided endoscopic procedures in the colon.
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Human Factors as assessed using the frequency of failure
Time Frame: 1 day
|
The design of the Poseidon System meets all acceptance criteria for design validation. User is able to operate device per the instructions for use. This criterion will be assessed in a pass/fail manner with an allowance of only 1 failure in the first 15 subjects and 1 failure in the second 15 subjects (if applicable). |
1 day
|
|
Colonoscope Control as assessed using a 5-point Likert scale from 1 (Strongly Disagree) to 5 (Strongly Agree).
Time Frame: 1 day
|
User shall not adversely influence typical actuation of a scope during colonoscopy procedure as assessed using a 5-point Likert scale.
|
1 day
|
|
Device Usability 1 as assessed using a 5-point Likert scale from 1 (Strongly Disagree) to 5 (Strongly Agree).
Time Frame: 1 day
|
User assessment of functional acceptability of Poseidon device ratchet location as assessed using a 5-point Likert scale.
|
1 day
|
|
Device Usability 2 as assessed using a 5-point Likert scale from 1 (Strongly Disagree) to 5 (Strongly Agree).
Time Frame: 1 day
|
User assessment of functional acceptability of Poseidon device intergluteal cleft fit as assessed using a 5-point Likert scale
|
1 day
|
|
Fluid retention as assessed using a 5-point Likert scale from 1 (Strongly Disagree) to 5 (Strongly Agree).
Time Frame: 1 day
|
The Poseidon System shall minimize passage of fluids through and around the scope lumen when a scope is in the device, as assessed using a 5-point Likert scale.
|
1 day
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Number of Adverse Events
Time Frame: 2 weeks
|
Safety defined as the occurrence of all adverse events measured from the Index Procedure through the 2 Week Post Procedure Follow-up Visit.
|
2 weeks
|
|
Time measured in minutes
Time Frame: 1 day
|
Procedure time measured in minutes from the point of scope insertion to the point of scope removal (scope-in / scope-out).
|
1 day
|
|
Number of Device Deficiencies
Time Frame: 1 day
|
Device deficiencies defined as an inadequacy of a medical device with respect to its identity, quality, durability, reliability, safety or performance including malfunctions, use errors, and inadequate labelling.
|
1 day
|
Collaborators and Investigators
This is where you will find people and organizations involved with this study.
Sponsor
Investigators
- Principal Investigator: Andrew Nettt, MD, Sutter Health
Study record dates
These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.
Study Major Dates
Study Start (Anticipated)
September 12, 2022
Primary Completion (Anticipated)
January 31, 2023
Study Completion (Anticipated)
March 31, 2023
Study Registration Dates
First Submitted
August 18, 2022
First Submitted That Met QC Criteria
August 19, 2022
First Posted (Actual)
August 23, 2022
Study Record Updates
Last Update Posted (Actual)
September 1, 2022
Last Update Submitted That Met QC Criteria
August 29, 2022
Last Verified
August 1, 2022
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- CLIN-0100
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
No
IPD Plan Description
Not applicable to this trial.
Trial and device validation will be used to commercially release product only.
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
No
Studies a U.S. FDA-regulated device product
Yes
product manufactured in and exported from the U.S.
Yes
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.