Criteria for enhancing mucus transport: a systematic scoping review

Alison Pieterse, Susan D Hanekom, Alison Pieterse, Susan D Hanekom

Abstract

Background: Uncertainty exists regarding the physiological basis of physiotherapy strategies to facilitate mucus clearance. The aim of this review was to describe the physiological factors and intrinsic conditions that facilitate airway mucus transport.

Method: A scoping review was performed. A systematic literature search of six databases was executed. Eligibility criteria were applied by two researchers to reach the aim of the review. Papers were identified independently by two reviewers on title, abstract and full-text level. Any discrepancies were discussed with a third reviewer.

Results: The search identified 35 papers published between 1975 and 2015. These differed significantly in terms of outcome measures, measurement techniques and methodologies and included animal studies, laboratory investigations, and the use of small human samples. Nine key factors influencing mucus transport were identified. These include: temperature and humidity, bronchial perfusion, ATP, forced expiratory technique and cough, generation of oscillation, ventilation patterns/airflow, epithelial differences, mucus properties and positioning.

Conclusion: This review provides a framework for factors/conditions influencing mucus transport. Existing physiotherapy strategies for augmentation of airway mucus clearance can now be evaluated against the framework and new modalities informed.

Keywords: Airway mucus clearance; Mucus transport; Scoping review.

Conflict of interest statement

Manuscript not reviewed by an ethics committee as no research intervention delivered.The authors declare that they have no competing interests.Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Figures

Fig. 1
Fig. 1
Review process flow diagram

References

    1. WHO. The End TB Strategy. WHO. 2017. . Accessed 24 Dec 2017.
    1. Datta S, Shah L, Gilman RH, Evans CA. Comparison of sputum collection methods for tuberculosis diagnosis: a systematic review and pairwise and network meta-analysis. Lancet Glob Health. 2017;5(8):e760–e771. doi: 10.1016/S2214-109X(17)30201-2.
    1. Randell SH, Boucher RC. Effective mucus clearance is essential for respiratory health. Am J Respir Cell Mol Biol. 2006;35:20–28. doi: 10.1165/rcmb.2006-0082SF.
    1. Sears PR, Yin W-N, Ostrowski LE. Continuous mucociliary transport by primary human airway epithelial cells in vitro. Am J Physiol - Lung Cell Mol Physiol. 2015;309:L99–108. doi: 10.1152/ajplung.00024.2015.
    1. Van Der Schans CP, Postma DS, Koëter GH, Rubin BK. Physiotherapy and bronchial mucus transport. Eur Respir J. 1999;13:1477–1486. doi: 10.1183/09031936.99.13614879.
    1. Pryor JA. Physiotherapy for airway clearance in adults. Eur Respir J. 1999;14:1418–1424. doi: 10.1183/09031936.99.14614189.
    1. Langenderfer B. Alternatives to percussion and postural drainage. A review of mucus clearance therapies: percussion and postural drainage, autogenic drainage, positive expiratory pressure, flutter valve, intrapulmonary percussive ventilation, and high-frequency chest compression with the Thairapy Vest. J Cardpulm Rehabil. 1998;18:283–9.
    1. Hristara-Papadopoulou A, Tsanakas J, Diomou G, Papadopoulou O. Current devices of respiratory physiotherapy. Hippokratia. 2008;12:211–220.
    1. Bhowmik A, Chahal K, Austin G, Chakravorty I. Improving mucociliary clearance in chronic obstructive pulmonary disease. Respir Med. 2009;103:496–502. doi: 10.1016/j.rmed.2008.10.014.
    1. Sethi S, Maloney J, Grove L, Anderson P. Comparison of the lung flute with the acapella in the treatment of COPD with chronic bronchitis. . Accessed 24 Apr 2018.
    1. Panaligan R, Mesina F, Mateo M. Comparison of active cycle breathing technique (ACBT)/forced expiration technique (FET) vs. Flutter device in facilitating sputum expectoration among stable COPD patients at UST hospital. Eur Respir J. 2012;40:no pagination. .
    1. Arksey H, O’Malley L. Scoping studies: towards a methodological framework. Int J Soc Res Methodol Theory Pract. 2005;8:19–32. doi: 10.1080/1364557032000119616.
    1. Moher D, Liberati A, Tetzlaff J, Altman DG, The PRISMA Group. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med. 2009;6(7):e1000097.
    1. Button B, Picher M, Boucher RC. Differential effects of cyclic and constant stress on ATP release and mucociliary transport by human airway epithelia. J Physiol. 2007;580:577–592. doi: 10.1113/jphysiol.2006.126086.
    1. Volpe MS, Adams AB, Amato MBP, Marini JJ. Ventilation patterns influence airway secretion movement. Respir Care. 2008;53:1287–1294.
    1. Li Bassi G, Saucedo L, Marti JD, Rigol M, Esperatti M, Luque N, et al. Effects of duty cycle and positive end-expiratory pressure on mucus clearance during mechanical ventilation*. Crit Care Med. 2012;40:895–902.
    1. Kim CS, Iglesias AJ, Sackner MA. Mucus clearance by two-phase gas-liquid flow mechanism: asymmetric periodic flow model. J Appl Physiol. 1987;62:959–971. doi: 10.1152/jappl.1987.62.3.959.
    1. Zahm JM, Pierrot D, Vaquez-Girod S, Duvivier C, King M, Puchelle E. The role of mucus sol phase in clearance by simulated cough. Biorheology. 1989;26:747–752. doi: 10.3233/BIR-1989-26407.
    1. Ragavan AJ, Evrensel CA, Krumpe P. Interactions of airflow oscillation, tracheal inclination, and mucus elasticity significantly improve simulated cough clearance. Chest. 2010;137:355–361. doi: 10.1378/chest.08-2096.
    1. King M. The role of mucus viscoelasticity in cough clearance. Biorheology. 1987;24:589–597. doi: 10.3233/BIR-1987-24611.
    1. Agarwal M, King M, Shukla JB. Mucous gel transport in a simulated cough machine: effects of longitudinal grooves representing spacings between arrays of cilia. Biorheology. 1994;31:11–19. doi: 10.3233/BIR-1994-31102.
    1. Eckerbom B, Lindholm C-E, Mannting F. Mucociliary transport with and without the use of a heat and moisture exchanger. An animal study. Acta Anaesthesiol Scand. 1991;35:297–301. doi: 10.1111/j.1399-6576.1991.tb03293.x.
    1. King M, Phillips DM, Gross D, Vartian V, Chang HK, Zidulka A. Enhanced tracheal mucus clearance with high frequency chest wall compression. Am Rev Respir Dis. 1983;128:511–515. doi: 10.1164/arrd.1983.128.3.511.
    1. King M, Phillips DM, Zidulka A, Chang HK. Tracheal mucus clearance in high-frequency oscillation. II: chest wall versus mouth oscillation. Am Rev Respir Dis. 1984;130:703–706.
    1. King M, Zidulka A, Phillips DM, Wight D, Gross D, Chang HK. Tracheal mucus clearance in high-frequency oscillation: effect of peak flow rate bias. Eur Respir J. 1990;3:6–13.
    1. Gross D, Zidulka A, O’Brien C, Wight D, Fraser R, Rosenthal L, et al. Peripheral mucociliary clearance with high-frequency chest wall compression. J Appl Physiol. 1985;58:1157–1163. doi: 10.1152/jappl.1985.58.4.1157.
    1. Rubin EM, Scantlen GE, Chapman GA, Eldridge M, Menendez R, Wanner A. Effect of chest wall oscillation on mucus clearance: comparison of two vibrators. Pediatr Pulmonol. 1989;6:122–126. doi: 10.1002/ppul.1950060213.
    1. Martí JD, Li Bassi G, Rigol M, Saucedo L, Ranzani OT, Esperatti M, et al. Effects of manual rib cage compressions on expiratory flow and mucus clearance during mechanical ventilation*. Crit Care Med. 2013;41:850–856. doi: 10.1097/CCM.0b013e3182711b52.
    1. Radford R, Barutt J, Billingsley J, Lawson W, Willich B. A rational basis for percussion-augmented Mucociliary clearance. Respir Care. 1982;27:556–563.
    1. Freitag L, Long WM, Kim CS, Wanner A. Removal of excessive bronchial secretions by asymmetric high-frequency oscillations. J Appl Physiol. 1989;67:614–619. doi: 10.1152/jappl.1989.67.2.614.
    1. Li Bassi G, Zanella A, Cressoni M, Stylianou M, Kolobow T. Following tracheal intubation, mucus flow is reversed in the semirecumbent position: possible role in the pathogenesis of ventilator–associated pneumonia. Crit Care Med. 2008;36:518–525. doi: 10.1097/01.CCM.0000299741.32078.E9.
    1. Bennett WD, Foster WM, Chapman WF, Michael W, Chapman F, Hill C, et al. Cough-enhanced mucus clearance in the normal lung. J Appl Physiol. 1990;69:1670–1675. doi: 10.1152/jappl.1990.69.5.1670.
    1. Kilgour E, Rankin N, Ryan S, Pack R. Mucociliary function deteriorates in the clinical range of inspired air temperature and humidity. Intensive Care Med. 2004;30:1491–1494. doi: 10.1007/s00134-004-2235-3.
    1. Lippmann M, Albert RE, Yeates DB, Berger JM, Foster WM, Bohning DE. Factors affecting tracheobronchial mucociliary transport. Inhaled Part. 1975;4(Pt 1):305–319.
    1. Puchelle E, Zahm JM, Jacquot J, Pierrot D. Effect of air humidity on spinability and transport capacity of canine airway secretions. Biorheology. 1989;26:315–322. doi: 10.3233/BIR-1989-26215.
    1. Wagner EM, Foster WM. Importance of airway blood flow on particle clearance from the lung. J Appl Physiol. 1996;81:1878–1883. doi: 10.1152/jappl.1996.81.5.1878.
    1. Gatto LA, Houck BM. Mucociliary transport and epithelial morphology with elongation and collapse in rat trachea. Exp Lung Res. 1989;15:239–251. doi: 10.3109/01902148909087856.
    1. Piccin VS, Calciolari C, Yoshizaki K, Gomes S, Albertini-Yagi C, Dolhnikoff M, et al. Effects of different mechanical ventilation strategies on the mucociliary system. Intensive Care Med. 2011;37:132–140. doi: 10.1007/s00134-010-2056-5.
    1. Wong JW, Keens TG, Wannamaker EM, Crozier DN, Levison H, Aspin N. Effects of gravity on tracheal mucus transport rates in normal subjects and in patients with cystic fibrosis. Pediatrics. 1977;60:146–152.
    1. Mortensen J, Jensen C, Groth S, Lange P. The effect of forced expirations on mucociliary clearance in patients with chronic bronchitis and in healthy subjects. Clin Physiol. 1991;11:439–450. doi: 10.1111/j.1475-097X.1991.tb00816.x.
    1. Diesel DA, Lebel JL, Tucker A. Pulmonary particle deposition and airway mucociliary clearance in cold-exposed calves. Am J Vet Res. 1991;52:1665–1671.
    1. Tatkov S, Pack RJ. Symmetrical-waveform high-frequency oscillation increases artificial mucus flow without changing basal mucus transport in in vitro ovine trachea. Respir Care. 2011;56:435–441. doi: 10.4187/respcare.00809.
    1. Freitag L, Kim CS, Long WM, Venegas J, Wanner A. Mobilization of mucus by airway oscillations. Acta Anaesthesiol Scand. 1989;33:93–101. doi: 10.1111/j.1399-6576.1989.tb03012.x.
    1. Trawöger R, Kolobow T, Patroniti N, Forcier K. Intratracheal pulmonary ventilation keeps tracheal tubes clean without impairing mucociliary transport. Scand J Clin Lab Invest. 2002;62:351–356. doi: 10.1080/00365510260296500.
    1. Kim CS, Greene MA, Sankaran S, Sackner MA, Rodriguez CR, Eldridge MA, et al. Mucus transport in the airways by two-phase gas-liquid flow mechanism: continuous flow model. J Appl Physiol. 1986;60:908–917. doi: 10.1152/jappl.1986.60.3.908.
    1. King M, Zahm JM, Pierrot D, Vaquez-Girod S, Puchelle E. The role of mucus gel viscosity, spinnability, and adhesive properties in clearance by simulated cough. Biorheology. 1989;26:737–745. doi: 10.3233/BIR-1989-26406.
    1. Yang T, Majima Y, Guo Y, Harada T, Shimizu T, Takeuchi K. Mucociliary transport function and damage of ciliated epithelium. Am J Rhinol. 2002;16:215–219.
    1. Lannefors L, Wollmer P. Mucus clearance with three chest physiotherapy regimes in cystic fibrosis: a comparison between postural drainage, PEP and physical exercise. Eur Respir J. 1992;5:748–753.
    1. Hooijmans CR, Rovers MM, De Vries RBM, Leenaars M, Ritskes-hoitinga M, Langendam MW. SYRCLE ’ s risk of bias tool for animal studies. BMC Med Res Methodol. 2014;14:1–9. doi: 10.1186/1471-2288-14-43.

Source: PubMed

3