A Polylactide Bioresorbable Scaffold Eluting Everolimus for Treatment of Coronary Stenosis: 5-Year Follow-Up

Patrick W Serruys, John Ormiston, Robert-Jan van Geuns, Bernard de Bruyne, Dariusz Dudek, Evald Christiansen, Bernard Chevalier, Pieter Smits, Dougal McClean, Jacques Koolen, Stephan Windecker, Robert Whitbourn, Ian Meredith, Luc Wasungu, Divine Ediebah, Susan Veldhof, Yoshinobu Onuma, Patrick W Serruys, John Ormiston, Robert-Jan van Geuns, Bernard de Bruyne, Dariusz Dudek, Evald Christiansen, Bernard Chevalier, Pieter Smits, Dougal McClean, Jacques Koolen, Stephan Windecker, Robert Whitbourn, Ian Meredith, Luc Wasungu, Divine Ediebah, Susan Veldhof, Yoshinobu Onuma

Abstract

Background: Long-term benefits of coronary stenosis treatment with an everolimus-eluting bioresorbable scaffold are unknown.

Objectives: This study sought to evaluate clinical and imaging outcomes 5 years after bioresorbable scaffold implantation.

Methods: In the ABSORB multicenter, single-arm trial, 45 (B1) and 56 patients (B2) underwent coronary angiography, intravascular ultrasound (IVUS), and optical coherence tomography (OCT) at different times. At 5 years, 53 patients without target lesion revascularization underwent final imaging.

Results: Between 6 months/1 year and 5 years, angiographic luminal late loss remained unchanged (B1: 0.14 ± 19 mm vs. 0.13 ± 0.33 mm; p = 0.7953; B2: 0.23 ± 0.28 mm vs. 0.18 ± 0.32 mm; p = 0.5685). When patients with a target lesion revascularization were included, luminal late loss was 0.15 ± 0.20 mm versus 0.15 ± 0.24 mm (p = 0.8275) for B1 and 0.30 ± 0.37 mm versus 0.32 ± 0.48 mm (p = 0.8204) for B2. At 5 years, in-scaffold and -segment binary restenosis was 7.8% (5 of 64) and 12.5% (8 of 64). On IVUS, the minimum lumen area of B1 decreased from 5.23 ± 0.97 mm(2) at 6 months to 4.89 ± 1.81 mm(2) at 5 years (p = 0.04), but remained unchanged in B2 (4.95 ± 0.91 mm(2) at 1 year to 4.84 ± 1.28 mm(2) at 5 years; p = 0.5). At 5 years, struts were no longer discernable by OCT and IVUS. On OCT, the minimum lumen area in B1 decreased from 4.51 ± 1.28 mm(2) at 6 months to 3.65 ± 1.39 mm(2) at 5 years (p = 0.01), but remained unchanged in B2, 4.35 ± 1.09 mm(2) at 1 year and 4.12 ± 1.38 mm(2) at 5 years (p = 0.24). Overall, the 5-year major adverse cardiac event rate was 11.0%, without any scaffold thrombosis.

Conclusions: At 5 years, bioresorbable scaffold implantation in a simple stenotic lesion resulted in stable lumen dimensions and low restenosis and major adverse cardiac event rates. (ABSORB Clinical Investigation, Cohort B [ABSORB B]; NCT00856856).

Keywords: angiography; coronary artery disease; follow-up studies; intravascular imaging; long-term; optical coherence; tomography.

Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.