Self-application of single-use eyedrop containers in an elderly population: comparisons with standard eyedrop bottle and with younger patients

Thomas S Dietlein, Jens F Jordan, Christoph Lüke, Andrea Schild, Sven Dinslage, Guenter K Krieglstein, Thomas S Dietlein, Jens F Jordan, Christoph Lüke, Andrea Schild, Sven Dinslage, Guenter K Krieglstein

Abstract

Purpose: To test whether patients aged >or=80 years can safely and successfully apply eyedrops from a single-use eyedrop container without support, and to compare the results with those of younger patients using single-use containers and older patients using standard eyedrop bottles.

Methods: Patients aged >or=80 years who had no physical or mental conditions hindering self-application of eyedrops and actually did so because of glaucoma or dry eyes were included consecutively in the study group (n = 44) in order to perform self-application of eyedrops from single-use eyedrop containers. Patients were observed meticulously by two investigators, who documented practical problems during the procedure in a checklist. In control group A (n = 22), glaucoma or sicca patients aged between 50 and 65 years applied drops from single-use eyedrop containers; in control group B (n = 28), glaucoma or sicca patients aged >or=80 years used a traditional eyedrop bottle.

Results: Successful application of the drops into the conjunctival sac was achieved by 57% in the study group (95% and 89% in control groups A and B, respectively). Scratching of the eyedrop container along the conjunctiva or cornea was observed in 68% of the study group (41% and 61% in control groups A and B, respectively). Frequency of problems during opening and self-application of single-use eyedrop containers in the study group showed an inverse correlation to visual acuity in the better eye and previous experience with this kind of eyedrop container.

Conclusion: Older patients have massive problems in self-administering eyedrops from single-use containers. Factors influencing the success of self-application may include the patient's previous experience with this kind of eyedrop container and the patient's visual acuity.