Seldinger Technique for Placement of "Peripheral" Internal Jugular Line: Novel Approach for Emergent Vascular Access

Adam J Ash, Christopher Raio, Adam J Ash, Christopher Raio

Abstract

This is a case report describing the ultrasound-guided placement of a peripheral intravenous catheter into the internal jugular vein of a patient with difficult vascular access. Although this technique has been described in the past, this case is novel in that the Seldinger technique was used to place the catheter. This allows for safer placement of a longer catheter (2.25″) without the need for venous dilation, which is potentially hazardous.

Figures

Figure 1
Figure 1
AccuCath® 2.25″ BC catheter.
Figure 2
Figure 2
A) Cross-sectional view of the left internal jugular vein with needle in lumen. B) Longitudinal view of guidewire in lumen of left internal jugular vein.

References

    1. Costantino TG, Parikh TK, Satz WA, et al. Ultrasonography-guided peripheral intravenous access versus traditional approach in patients with difficult intravenous access. Ann Emerg Med. 2005;46(5):456–61.
    1. Jones SE, Nespert P, Alcoaloumre E. Prehospital intravenous line placement: a prospective study. Ann Emerg Med. 1989;18:244–6.
    1. Panebianco NL, Fredette JM, Szyld D, et al. What you see (sonographically) is what you get: vein and patient characteristics associated with successful ultrasound-guided peripheral intravenous placement in patients with difficult access. Acad Emerg Med. 2009;16:1298–303.
    1. Teismann NA, Knight RS, Rehrer M, et al. The ultrasound guided “peripheral IJ”: Internal jugular vein catheterization using a standard intravenous catheter. JEM. 2013;44(1):150–4.
    1. Moayedi S. Ultrasound-guided venous access with a single lumen catheter into the internal jugular vein. JEM. 2009;37(4):419–24.
    1. Higgs Z, Macafee D, Braithwaite D, et al. The Seldinger technique: 50 years on. Lancet. 2005;366:1407–9.
    1. Hind D, Calvert N, McWilliams R, et al. Ultrasonic locating devices for central venous cannulation: metaanalysis. BMJ. 2003;327:361–4.
    1. Blaivas M. Video analysis of accidental arterial cannulation with dynamic ultrasound guidance for central venous access. J Ultrasound Med. 2009;28:1239–44.
    1. Gillman LM, Blaivas M, Lord J, et al. Ultrasound confirmation of guidewire position may eliminate accidental arterial dilatation during central venous cannulation. Scand J Trauma Resusc Emerg Med. 2010;18:39.
    1. Khasawneh FA, Smalligan RD. Guidewire related complications during central venous catheter placement: A case report and review of the literature. Case Rep Crit Care. 2011