The effects of professional continuous glucose monitoring as an adjuvant educational tool for improving glycemic control in patients with type 2 diabetes

Dulce Adelaida Rivera-Ávila, Alejandro Iván Esquivel-Lu, Carlos Rafael Salazar-Lozano, Kyla Jones, Svetlana V Doubova, Dulce Adelaida Rivera-Ávila, Alejandro Iván Esquivel-Lu, Carlos Rafael Salazar-Lozano, Kyla Jones, Svetlana V Doubova

Abstract

Background: The study objective was to evaluate the effects of professional continuous glucose monitoring (CGM) as an adjuvant educational tool for improving glycemic control in patients with type 2 diabetes (T2D).

Methods: We conducted a three-month quasi-experimental study with an intervention (IGr) and control group (CGr) and ex-ante and ex-post evaluations in one family medicine clinic in Mexico City. Participants were T2D patients with HbA1c > 8% attending a comprehensive diabetes care program. In addition to the program, the IGr wore a professional CGM sensor (iPro™2) during the first 7 days of the study. Following this period, IGr participants had a medical consultation for the CGM results and treatment adjustments. Additionally, they received an educational session and personalized diet plan from a dietitian. After 3 months, the IGr again wore the CGM sensor for 1 week. The primary outcome variable was HbA1c level measured at baseline and 3 months after the CGM intervention. We analyzed the effect of the intervention on HbA1c levels by estimating the differences-in-differences treatment effect (Diff-in-Diff). Additionally, baseline and three-month CGM and dietary information were recorded for the IGr and analyzed using the Student's paired t-test and mixed-effects generalized linear models to control for patients' baseline characteristics.

Results: Overall, 302 T2D patients participated in the study (IGr, n = 150; control, n = 152). At the end of the three-month follow-up, we observed 0.439 mean HbA1C difference between groups (p = 0.004), with an additional decrease in HbA1c levels in the IGr compared with the CGr (Diff-in-Diff HbA1c mean of - 0.481% points, p = 0.023). Moreover, compared with the baseline, the three-month CGM patterns showed a significant increase in the percentage of time in glucose range (+ 7.25; p = 0.011); a reduction in the percentage of time above 180 mg/dl (- 6.01; p = 0.045), a decrease in glycemic variability (- 3.94, p = 0.034); and improvements in dietary patterns, shown by a reduction in total caloric intake (- 197.66 Kcal/day; p = 0.0001).

Conclusion: Professional CGM contributes to reducing HbA1c levels and is an adjuvant educational tool that can improve glycemic control in patients with T2D.

Trial registration: ClinicalTrials.gov: NCT04667728 . Registered 16/12/2020.

Keywords: Educational tool; Glycemic control; Professional continuous glucose monitoring; Type 2 diabetes.

Conflict of interest statement

KJ is an employee of Medtronic PLC. The authors declare their complete independence from Medtronic PLC during the entire research process and are solely responsible for the methods, results, concepts, and conclusions contained in this manuscript.

References

    1. International Diabetes Federation. IDF diabetes atlas. 9th ed: International Diabetes Federation; 2019. Available at:
    1. Rodriguez-Gutierrez R, Gonzalez-Gonzalez JG, Zuñiga-Hernandez JA, McCoy RG. Benefits and harms of intensive glycemic control in patients with type 2 diabetes. BMJ. 2019;367:l5887. doi: 10.1136/bmj.l5887.
    1. Ratner RE. Glycemic control in the prevention of diabetic complications. Clin Cornerstone. 2001;4(2):24–37. doi: 10.1016/s1098-3597(01)90027-4.
    1. Manne-Goehler J, Geldsetzer P, Agoudavi K, Andall-Brereton G, Aryal KK, Bicaba BW, Bovet P, Brian G, Dorobantu M, Gathecha G, Singh Gurung M, Guwatudde D, Msaidie M, Houehanou C, Houinato D, Jorgensen JMA, Kagaruki GB, Karki KB, Labadarios D, Martins JS, Mayige MT, McClure RW, Mwalim O, Mwangi JK, Norov B, Quesnel-Crooks S, Silver BK, Sturua L, Tsabedze L, Wesseh CS, Stokes A, Marcus M, Ebert C, Davies JI, Vollmer S, Atun R, Bärnighausen TW, Jaacks LM. Health system performance for people with diabetes in 28 low- and middle-income countries: a cross-sectional study of nationally representative surveys. PLoS Med. 2019;16(3):e1002751. doi: 10.1371/journal.pmed.1002751.
    1. Krhač M, Lovrenčić MV. Update on biomarkers of glycemic control. World J Diabetes. 2019;10(1):1–15. doi: 10.4239/wjd.v10.i1.1.
    1. Kumar R, Raviteja KV, Sachdeva N, Dayal D. Feasibility and acceptability of professional continuous glucose monitoring system in children with type 1 diabetes mellitus: an observational study. J Diabetol. 2019;10(1):15–20. doi: 10.4103/jod.jod_13_18.
    1. Carlson AL, Mullen DM, Bergenstal RM. Clinical use of continuous glucose monitoring in adults with type 2 diabetes. Diabetes Technol Ther. 2017;19(S2):S4–S11. doi: 10.1089/dia.2017.0024.
    1. Park C, Le QA. The effectiveness of continuous glucose monitoring in patients with type 2 diabetes: a systematic review of literature and meta-analysis. Diabetes Technol Ther. 2018;20(9):613–621. doi: 10.1089/dia.2018.0177.
    1. Taylor PJ, Thompson CH, Brinkworth GD. Effectiveness and acceptability of continuous glucose monitoring for type 2 diabetes management: a narrative review. J Diabetes Investig. 2018;9(4):713–725. doi: 10.1111/jdi.12807.
    1. Murphy HR, Rayman G, Lewis K, Kelly S, Johal B, Duffield K, Fowler D, Campbell PJ, Temple RC. Effectiveness of continuous glucose monitoring in pregnant women with diabetes: randomised clinical trial. BMJ. 2008;337(sep25 2):a1680. doi: 10.1136/bmj.a1680.
    1. Teodoro de Oliveira AO, Bartholomew K, Lavin-Tompkins J, Sperl-Hillen J. Use of continuous glucose monitoring as an educational tool in the primary care setting. Diabetes Spectr. 2013;26(2):120–123. doi: 10.2337/diaspect.26.2.120.
    1. Gill M, Zhu C, Shah M, Chhabra H. Health care costs, hospital admissions, and glycemic control using a standalone, real-time, continuous glucose monitoring system in commercially insured patients with type 1 diabetes. J Diabetes Sci Technol. 2018;12(4):800–807. doi: 10.1177/1932296818777265.
    1. Parkin CG, Graham C, Smolskis J. Continuous glucose monitoring use in type 1 diabetes: longitudinal analysis demonstrates meaningful improvements in HbA1c and reductions in health care utilization. J Diabetes Sci Technol. 2017;11(3):522–528. doi: 10.1177/1932296817693253.
    1. Bruttomesso D, Laviola L, Avogaro A, Bonora E, del Prato S, Frontoni S, Orsi E, Rabbone I, Sesti G, Purrello F, of the Italian Diabetes Society (SID) The use of real time continuous glucose monitoring or flash glucose monitoring in the management of diabetes: a consensus view of Italian diabetes experts using the Delphi method. Nutr Metab Cardiovasc Dis. 2019;29(5):421–431. doi: 10.1016/j.numecd.2019.01.018.
    1. Reddy N, Verma N, Dungan K, et al. Monitoring technologies- continuous glucose monitoring, mobile technology, biomarkers of glycemic control. In: Feingold KR, Anawalt B, Boyce A, et al., editors. Endotext. South Dartmouth: , Inc.; 2000.
    1. Basto-Abreu A, Barrientos-Gutiérrez T, Rojas-Martínez R, Aguilar-Salinas CA, López-Olmedo N, de la Cruz-Góngora V, Rivera-Dommarco J, Shamah-Levy T, Romero-Martínez M, Barquera S, López-Ridaura R, Hernández-Ávila M, Villalpando S. Prevalence of diabetes and poor glycemic control in Mexico: results from Ensanut 2016. Salud Publica Mex. 2020;62(1):50–59. doi: 10.21149/10752.
    1. ISSSTE. Estadística. Anuarios 2019. Capítulo 1. Estadísticas de población. Población Amparada por Entidad Federativa. Mexico; 2019. Availabale at: . Accessed 7 Aug 2020.
    1. Instituto de Seguridad y Servicios Sociales de los Trabajadores del Estado. Mexico. Prensa 14 de Noviembre de 2019. ; . Accessed 22 Feb 2020.
    1. Blanco-Cornejo M, Riva-Palacio-Chiang-Sam IL, Sánchez-Díaz I, et al. New model for diabetes primary health care based on patient empowerment and the right to preventive health: the MIDE program. Rev Panam Salud Publica. 2017;41:e128. doi: 10.26633/RPSP.2017.128.
    1. Danne T, Nimri R, Battelino T, Bergenstal RM, Close KL, DeVries JH, Garg S, Heinemann L, Hirsch I, Amiel SA, Beck R, Bosi E, Buckingham B, Cobelli C, Dassau E, Doyle FJ, III, Heller S, Hovorka R, Jia W, Jones T, Kordonouri O, Kovatchev B, Kowalski A, Laffel L, Maahs D, Murphy HR, Nørgaard K, Parkin CG, Renard E, Saboo B, Scharf M, Tamborlane WV, Weinzimer SA, Phillip M. International consensus on use of continuous glucose monitoring. Diabetes Care. 2017;40(12):1631–1640. doi: 10.2337/dc17-1600.
    1. Rosner B. Fundamentals of biostatistics. 5. Pacific Grove: Duxbury Ress; 2000.
    1. Villa JM. Diff: simplifying the estimation of difference-in-differences treatment effects. Stata J. 2016;16(1):52–71. doi: 10.1177/1536867X1601600108.
    1. Dziura JD, Post LA, Zhao Q, Fu Z, Peduzzi P. Strategies for dealing with missing data in clinical trials: from design to analysis. Yale J Biol Med. 2013;86(3):343–358.
    1. Hernán MA, Robins JM. Causal inference. Boca Raton: Chapman & Hall/CRC; 2015.
    1. Seaman SR, White IR. Review of inverse probability weighting for dealing with missing data. Stat Methods Med Res. 2013;22(3):278–295. doi: 10.1177/0962280210395740.
    1. Bergenstal RM. Role of continuous glucose monitoring in diabetes treatment. Arlington: American Diabetes Association; 2018. Understanding continuous glucose monitoring data.
    1. Lawton J, Blackburn M, Allen J, Campbell F, Elleri D, Leelarathna L, Rankin D, Tauschmann M, Thabit H, Hovorka R. Patients’ and caregivers’ experiences of using continuous glucose monitoring to support diabetes self-management: qualitative study. BMC Endocr Disord. 2018;18(1):12. doi: 10.1186/s12902-018-0239-1.
    1. Aleppo G. Role of continuous glucose monitoring in diabetes treatment. Arlington: American Diabetes Association; 2018. Approaches for successful outcomes with continuous glucose monitoring.
    1. Glooko. Annual diabetes report 2017. Available from . Accessed 3 Mar 2018.
    1. Rodbard D. Continuous glucose monitoring: a review of recent studies demonstrating improved glycemic outcomes. Diabetes Technol Ther. 2017;19(S3):S25–S37. doi: 10.1089/dia.2017.0035.
    1. Yoo HJ, An HG, Park SY, Ryu OH, Kim HY, Seo JA, Hong EG, Shin DH, Kim YH, Kim SG, Choi KM, Park IB, Yu JM, Baik SH. Use of a real time continuous glucose monitoring system as a motivational device for poorly controlled type 2 diabetes. Diabetes Res Clin Pract. 2008;82(1):73–79. doi: 10.1016/j.diabres.2008.06.015.
    1. Cox DJ, Taylor AG, Moncrief M, Diamond A, Yancy WS, Jr, Hegde S, McCall AL. Continuous glucose monitoring in the self-management of type 2 diabetes: a paradigm shift. Diabetes Care. 2016;39(5):E71–E73. doi: 10.2337/dc15-2836.
    1. Sherwani SI, Khan HA, Ekhzaimy A, Masood A, Sakharkar MK. Significance of HbA1c test in diagnosis and prognosis of diabetic patients. Biomark Insights. 2016;11:95–104. doi: 10.4137/BMI.S38440.
    1. Zhang Y, Hu G, Yuan Z, Chen L. Glycosylated hemoglobin in relationship to cardiovascular outcomes and death in patients with type 2 diabetes: a systematic review and meta-analysis. PLoS One. 2012;7(8):e42551. doi: 10.1371/journal.pone.0042551.
    1. Sierra JA, Shah M, Gill MS, Flores Z, Chawla H, Kaufman FR, Vigersky R. Clinical and economic benefits of professional CGM among people with type 2 diabetes in the United States: analysis of claims and lab data. J Med Econ. 2018;21(3):225–230. doi: 10.1080/13696998.2017.1390474.

Source: PubMed

3
Subscribe