The use of wearable inertial motion sensors in human lower limb biomechanics studies: a systematic review

Daniel Tik-Pui Fong, Yue-Yan Chan, Daniel Tik-Pui Fong, Yue-Yan Chan

Abstract

Wearable motion sensors consisting of accelerometers, gyroscopes and magnetic sensors are readily available nowadays. The small size and low production costs of motion sensors make them a very good tool for human motions analysis. However, data processing and accuracy of the collected data are important issues for research purposes. In this paper, we aim to review the literature related to usage of inertial sensors in human lower limb biomechanics studies. A systematic search was done in the following search engines: ISI Web of Knowledge, Medline, SportDiscus and IEEE Xplore. Thirty nine full papers and conference abstracts with related topics were included in this review. The type of sensor involved, data collection methods, study design, validation methods and its applications were reviewed.

Keywords: accelerometers; gyroscopes; inertial sensors; joint kinematics; magnetic sensors; motion analysis.

Figures

Figure 1.
Figure 1.
Research method of this study.

References

    1. Cooper G, Sheret I, McMillian L, Siliverdis K, Sha N, Hodgins D, Kenney L, Howard D. Inertial sensor-based knee flexion/extension angle estimation. J Biomech. 2009;42:2678–1685.
    1. Coley B, Najafi B, Paraschiv-Ionescu A, Aminian K. Stair climbing detection during daily physical activity using a miniature gyroscope. Gait Posture. 2005;22:287–294.
    1. Willemsen ATM, Frigo C, Boom HBK. Lower extremity angle measurement with accelerometers-error and sensitivity analysis. IEEE Trans Biomed Eng. 1991;38:1186–1193.
    1. Heyn A, Mayagoitia RE, Nene AV, Veltink P. The kinematics of the swing phase obtained from accelerometer and gyroscope measurements. Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society; Amsterdam, The Netherlands. 31 October–3 November 1996; pp. 463–464.
    1. Morris JRW. Accelerometry—A technique for the measurement of human body movements. J Biomech. 1973;6:729–736.
    1. O’Donovan KJ, Kamnik R, O’Keeffe DT, Lyons GM. An inertial and magnetic sensor based technique for joint angle measurement. J Biomech. 2007;40:2604–2611.
    1. Favre J, Jolles BM, Aissaoui R, Aminian K. Ambulatory measurement of 3D knee joint angle. J Biomech. 2008;41:1029–1035.
    1. Favre J, Luthi F, Jolles BM, Siegrist O, Najafi B, Aminian K. A new ambulatory system for comparative evaluation of the three-dimensional knee kinematics, applied to anterior cruciate ligament injuries. Knee Surg Sports Traumatol Ar. 2006;14:592–604.
    1. Cutti AG, Ferrari A, Garofalo P, Raggi M, Cappello A, Ferrari A. Outwalk: A protocol for clinical gait analysis based on inertial and magnetic sensors. Med Biol Eng Comput. 2010;48:17–25.
    1. Music J, Kamnik R, Munih M. Model based inertial sensing of human body motion kinematics in sit-to-stand movement. Simul Model Pract Theory. 2008;16:933–944.
    1. van den Noort JC, Scholtes VA, Harlaar J. Evaluation of clinical spasticity assessment in Cerebral palsy using inertial sensors. Gait Posture. 2009;30:138–143.
    1. Kawano K, Kobashi S, Yagi M, Kondo K, Yoshiya S, Hata T. Analyzing 3D knee kinematics using accelerometers, gyroscopes and magnetometers. Proceedings of IEEE Conference on Systems Engineering 2007; San Antonio, TX, USA. 16–18 April 2007; pp. 1–6.
    1. Kawano K, Kobashi S, Tsumori Y, Shibanuma N, Imawaki S, Yagi M, Yoshiya S, Hata Y. Evaluation of pivot shift in the anterior cruciate ligament-injured knee using inertial and magnetic sensors. Proceedings of Automation Congress; Waikoloa, HI, USA. 28 September–2 October 2008; pp. 1–6.
    1. Zijlstra A, Goosen JHM, Verheyen CCPM, Zijlstra W. A body-fixed-sensor based analysis of compensatory trunk movements during unconstrained walking. Gait Posture. 2008;27:164–167.
    1. Andrews DM, Dowling JJ. Mechanical modeling of tibial axial accelerations following impulsive heel impact. J Appl Biomech. 2000;16:276–288.
    1. Avor JK. An approach to sensor fusion in medical robots. Proceedings of IEEE 11th International Conference on Rehabilitation Robotics; Kyoto, Japan. 23–26 June 2009; pp. 818–822.
    1. Chan YY, Fong DTP, Chung MML, Li WJ, Liao WH, Yung PSH, Chan KM. Identification of ankle sprain motion from common sporting activities by dorsal foot kinematics data. J Biomech. 2010;43:1965–1969.
    1. Dejnabadi H, Jolles BM, Aminian K. A new approach to accurate measurement of uniaxial joint angles based on a combination of accelerometers and gyroscopes. IEEE Trans Biomed Eng. 2005;52:1478–1484.
    1. Dejnabadi H, Jolles BM, Casanova E, Fua P. Estimation and visualization of sagittal kinematics of lower limbs orientation using body-fixed sensors. IEEE Trans Biomed Eng. 2006;53:1385–1393.
    1. Ermes M, Pärkkä J. Detection of daily activities and sports with wearable sensors in controlled and uncontrolled conditions. IEEE Trans Inf Technol Biomed. 2008;12:20–26.
    1. Favre J, Aissaoui R, Jolles BM, de Guise JA, Aminian K. Functional calibration procedure for 3D knee joint angle description using inertial sensors. J Biomech. 2009;42:2330–2335.
    1. Findlow A, Goulermas JS, Nester C, Howard D, Kenney LPJ. Predicting lower limb joint kinematics using wearable motion sensors. Gait Posture. 2008;28:120–126.
    1. Hanlon M, Anderson R. Real-time gait event detection using wearable sensors. Gait Posture. 2009;30:523–527.
    1. Helot R, Pissard-Gibollet R, Espiau B, Favre-Reguillon F. Continuous identification of gait phase for robotics and rehabilitation using microsensors. Proceedings of IEEE 12th International Conference on Advanced Robotics; Seattle, WA, USA. 18–20 July 2005; pp. 686–691.
    1. Kendell C. Effect of mobility devices on orientation sensors that contain magnetometers. J Rehabil Res Dev. 2009;46:957–962.
    1. Lau HY, Tong KY, Zhu H. Support vector machine for classification of walking conditions of persons after stroke with dropped foot. Hum Movement Sci. 2009;28:504–514.
    1. L’Hemette M, Savatier X, Baudry L, Tourny-Chollet C, Dujardin F. A new portable device for assessing locomotor performance. Int J Sports Med. 2008;29:322–326.
    1. Liu T, Inoue Y, Shibata K. Measurement of muscle motion for improving accuracy of body-mounted motion sensor. Proceedings of IEEE/ASME International Conference on Advanced Intelligent Mechatronics; Xi’an, China. 2–5 July 2008; pp. 1325–1330.
    1. Liu K, Liu T, Shibata K, Inoue Y, Zheng R. Novel approach to ambulatory assessment of human segmental orientation on a wearable sensor system. J Biomech. 2009;42:2747–2752.
    1. Mamizuka N, Sakane M, Kaneoka K, Hori N, Ochiai N. Kinematic quantitation of the patellar tendon reflex using a tri-axial accelerometer. J Biomech. 2007;40:2107–2111.
    1. Mayagoitia RE, Nene AV, Veltink PH. Accelerometer and rate gyroscope measurement of kinematics: An inexpensive alternative to optical motion analysis systems. J Biomech. 2002;35:537–542.
    1. Picermo P, Cereatti A, Cappozzo A. Joint kinematics estimate using wearable inertial and magnetic sensing modules. Gait Posture. 2008;28:588–595.
    1. Saber-Sheikh K, Bryant EC, Glazzard C, Hamel A, Lee RYW. Feasibility of using inertial sensors to assess human movement. Man Ther. 2010;15:122–125.
    1. Simcox S, Parker S, Davis GM, Smith RW, Middleton JW. Performance of orientation sensors for use with a functional electrical stimulation mobility system. J Biomech. 2005;38:1185–1190.
    1. Tong K, Granat MH. A practical gait analysis system using gyroscopes. Med Eng Phys. 1999;21:87–94.
    1. Willemsen AT, van Alste JA, Boom HB. Real-time gait assessment utilizing a new way of accelerometry. J Biomech. 1990;23:859–863.
    1. Zhang Z, Wu JK, Huang Z. Gaussian particle filter for tracking hip angle in gait cycles. Proceedings of 10th International Conference on e-health Networking, Applications and Services, 2008; Singapore. 7–9 July 2008; pp. 177–181.
    1. Ahmadi A, Rowlands DD, James DA. Investigating the translational and rotational motion of the swing using accelerometers for athlete skill assessment. Proceedings of 5th IEEE Conference on Sensors; Daegu, Korea. 22–25 October 2006; pp. 980–983.
    1. Clark RA, Bartold S, Bryant AL. Tibial acceleration variability during consecutive gait cycles is influenced by the menstrual cycle. Clin Biomech. 2010;25:557–562.

Source: PubMed