Inadequate gastric preparation and its associated factors for magnetically controlled capsule endoscopy

Qing-Zhou Kong, Cheng Peng, Zhen Li, Bao-Ling Tian, Yue-Yue Li, Fei-Xue Chen, Xiu-Li Zuo, Yan-Qing Li, Qing-Zhou Kong, Cheng Peng, Zhen Li, Bao-Ling Tian, Yue-Yue Li, Fei-Xue Chen, Xiu-Li Zuo, Yan-Qing Li

Abstract

Goals: To explore factors associated with inadequate gastric preparation for MCE. Background: Factors associated with inadequate gastric preparation for magnetically controlled capsule endoscopy (MCE) remains unclear. Study: Data of patients who underwent MCE from June 2021 to July 2022 were prospectively collected. The gastric cleanliness score (GCS) of the six stomach regions (gastric cardia, fundus, body, angulus, antrum, and pylorus) was recorded. Patients with GCS score ≥18 were defined as the adequate preparation. Factors related to inadequate gastric preparation were analyzed using a logistic regression model with estimated odds ratios (OR). Results: The mean GCS score of 211 patients was 17.01 ± 2.82. In the multivariable analysis, proton pump inhibitor (PPI) use (OR 3.57; 95% CI 1.69-7.95; p < 0.01) and premedication time after administering simethicone <30 min (OR 2.86; 95% CI 1.10-7.39; p = 0.03) were independent risk factors for inadequate gastric preparation. Comparing the gastric cleanliness of different locations, the median GCS of the lower stomach [10.00, IQR (9.50, 11.00)] was significantly higher than that of the upper stomach [7.00, IQR (6.00, 8.00)] (p <0.001). Conclusion: PPI use and inadequate premedication time (<30 min) may reduce the quality of gastric preparation for MCE. The type, dose, duration of medication, and discontinuation time of PPIs was well worth further exploration. Appropriate control of the type and time of premedication may be the key to improving overall gastric cleanliness.

Keywords: gastric disease; magnetically controlled capsule endoscopy; preparation; proton pump inhibitor; simethicone.

Conflict of interest statement

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Copyright © 2023 Kong, Peng, Li, Tian, Li, Chen, Zuo and Li.

Figures

FIGURE 1
FIGURE 1
The 4-point grading scales for the gastric cleanliness of six gastric landmarks in MCE.
FIGURE 2
FIGURE 2
Comparison of upper and lower gastric cleanliness score. The median GCS of lower stomach was significantly higher than that of upper stomach (*** represents p <0.001).

References

    1. Anjiki H., Sanaka M., Kuyama Y. (2005). Dual effects of rabeprazole on solid-phase gastric emptying assessed by the 13C-octanoate breath test. Digestion 72, 189–194. 10.1159/000088465
    1. Bhandari P., Green S., Hamanaka H., Nakajima T., Matsuda T., Saito Y., et al. (2010). Use of gascon and pronase either as a pre-endoscopic drink or as targeted endoscopic flushes to improve visibility during gastroscopy: A prospective, randomized, controlled, blinded trial. Scand. J. Gastroenterol. 45, 357–361. 10.3109/00365520903483643
    1. Capsule Endoscopy Group of the Chinese Society of Digestive Endoscopy (2021). Capsule Endoscopy Collaborative Group of Chinese Society of D, et al. Chinese guideline on magnetically controlled capsule gastroscopy (2021, Shanghai). Chin. J. Dig. Endosc. 38, 949–963. 10.1111/1751-2980.13173
    1. Chang W. K., Yeh M. K., Hsu H. C., Chen H. W., Hu M. K. (2014). Efficacy of simethicone and N-acetylcysteine as premedication in improving visibility during upper endoscopy. J. Gastroenterol. Hepatol. 29, 769–774. 10.1111/jgh.12487
    1. Chinese Digestive Endoscopist Committee, Chinese Endoscopist Association, the Health Management and Physical Examination Committee of Digestive Endoscopy, Capsule Endoscopy Collaboration Group of Chinese Society of Digestive Endoscopy, Chinese Anti-Cancer Association, the Society of Oncological Endoscopy, Chinese Society of Health Management (2017). The China expert consensus of clinical practice for magnetically controlled capsule gastroscopy(2017, Shanghai). Zhonghua Nei Ke Za Zhi 56, 876–884. 10.3760/cma.j.issn.0578-1426.2017.11.023
    1. Eliakim R. (2017). Where do I see minimally invasive endoscopy in 2020: clock is ticking. Ann. Transl. Med. 5, 202. 10.21037/atm.2017.04.17
    1. Elvas L., Areia M., Brito D., Alves S., Saraiva S., Cadime A. T. (2017). Premedication with simethicone and N-acetylcysteine in improving visibility during upper endoscopy: A double-blind randomized trial. Endoscopy 49, 139–145. 10.1055/s-0042-119034
    1. Geropoulos G., Aquilina J., Kakos C., Anestiadou E., Giannis D. (2021). Magnetically controlled capsule endoscopy versus conventional gastroscopy: A systematic review and meta-analysis. J. Clin. Gastroenterol. 55, 577–585. 10.1097/MCG.0000000000001540
    1. Jiang X., Qiu X. O., Li Z., Pan J., Peng C., Zuo X. L., et al. (2022). Small-sized versus standard magnetic capsule endoscopy in adults: A two-center, double-blinded randomized controlled trial. Endoscopy 55, 52–57. 10.1055/a-1881-4369
    1. Keller J., Fibbe C., Volke F., Gerber J., Mosse A. C., Reimann-Zawadzki M., et al. (2011). Inspection of the human stomach using remote-controlled capsule endoscopy: A feasibility study in healthy volunteers (with videos). Gastrointest. Endosc. 73, 22–28. 10.1016/j.gie.2010.08.053
    1. Kim H., Hwang Y., Sung H., Jang J., Ahn C., Kim S. G., et al. (2018). Effectiveness of gastric cancer screening on gastric cancer incidence and mortality in a community-based prospective cohort. Cancer Res. Treat. 50, 582–589. 10.4143/crt.2017.048
    1. Li J., Li L., Fu Z. (2020). The effect of proton pump inhibitor on the image quality of magnetically controlled capsule endoscopy in aging patients. Gastroenterology 158, S565. 10.1016/S0016-5085(20)32115-6
    1. Li Z., Liu J., Ji C. R., Chen F. X., Liu F. G. (2021). Screening for upper gastrointestinal cancers with magnetically controlled capsule gastroscopy: A feasibility study. Endoscopy 53, 914–919. 10.1055/a-1333-2120
    1. Liao Z., Duan X. D., Xin L., Bo L. M., Wang X. H., Xiao G. H., et al. (2012). Feasibility and safety of magnetic-controlled capsule endoscopy system in examination of human stomach: A pilot study in healthy volunteers. J. Interv. Gastroenterol. 2, 155–160. 10.4161/jig.23751
    1. Liao Z., Hou X., Lin-Hu E. Q., Sheng J. Q., Ge Z. Z., Jiang B., et al. (2016). Accuracy of magnetically controlled capsule endoscopy, compared with conventional gastroscopy, in detection of gastric diseases. Clin. Gastroenterol. Hepatol. 14, 1266–1273. 10.1016/j.cgh.2016.05.013
    1. Liu X., Guan C. T., Xue L. Y., He S., Zhang Y. M., Zhao D. L., et al. (2018). Effect of premedication on lesion detection rate and visualization of the mucosa during upper gastrointestinal endoscopy: A multicenter large sample randomized controlled double-blind study. Surg. Endosc. 32, 3548–3556. 10.1007/s00464-018-6077-4
    1. Malfertheiner P., Megraud F., Rokkas T., Gisbert J. P., Liou J. M. (2022). Management of Helicobacter pylori infection: the maastricht VI/florence consensus report. Gut 71, 1724–1762. 10.1136/gutjnl-2022-327745
    1. Ota K., Takeuchi T., Kojima Y., Kawaguchi S., Iwatsubo T. (2021). Administration of a standard dose of vonoprazan fumarate delays gastric emptying in Japanese healthy adults: A prospective clinical trial. J. Gastroenterol. 56, 722–731. 10.1007/s00535-021-01801-3
    1. Parkman H. P., Urbain J. L., Knight L. C., Brown K. L., Trate D. M., Miller M. A., et al. (1998). Effect of gastric acid suppressants on human gastric motility. Gut 42, 243–250. 10.1136/gut.42.2.243
    1. Rahman I., Pioche M., Shim C. S., Sung I. K., Saurin J. C. (2016). Magnetic-assisted capsule endoscopy in the upper GI tract by using a novel navigation system (with video). Gastrointest. Endosc. 83, 889–895. 10.1016/j.gie.2015.09.015
    1. Rey J. F., Ogata H., Hosoe N., Ohtsuka K., Ogata N., Ikeda K., et al. (2012). Blinded nonrandomized comparative study of gastric examination with a magnetically guided capsule endoscope and standard videoendoscope. Gastrointest. Endosc. 75, 373–381. 10.1016/j.gie.2011.09.030
    1. Sanaka M., Anjiki H., Yamamoto T., Kuyama Y. (2007). Rabeprazole delays gastric emptying of a nutrient liquid. J. Gastroenterol. Hepatol. 22, 1806–1809. 10.1111/j.1440-1746.2006.04763.x
    1. Sanaka M., Yamamoto T., Kuyama Y. (2010). Effects of proton pump inhibitors on gastric emptying: A systematic review. Dig. Dis. Sci. 55, 2431–2440. 10.1007/s10620-009-1076-x
    1. Takahashi Y., Amano Y., Yuki T., Ose T., Miyake T., Kushiyama Y., et al. (2006). Influence of acid suppressants on gastric emptying: cross-over analysis in healthy volunteers. J. Gastroenterol. Hepatol. 21, 1664–1668. 10.1111/j.1440-1746.2006.04270.x
    1. Van Cutsem E., Sagaert X., Topal B., Haustermans K., Prenen H. (2016). Gastric cancer. Lancet 388, 2654–2664. 10.1016/S0140-6736(16)30354-3
    1. Wang Y. C., Pan J., Jiang X., Su X. J., Zhou W., Zou W. B., et al. (2019). Repetitive position change improves gastric cleanliness for magnetically controlled capsule gastroscopy. Dig. Dis. Sci. 64, 1297–1304. 10.1007/s10620-018-5415-7
    1. Woo J. G., Kim T. O., Kim H. J., Shin B. C., Seo E. H., Heo N. Y., et al. (2013). Determination of the optimal time for premedication with pronase, dimethylpolysiloxane, and sodium bicarbonate for upper gastrointestinal endoscopy. J. Clin. Gastroenterol. 47, 389–392. 10.1097/MCG.0b013e3182758944
    1. Wynants L., Bouwmeester W., Moons K. G., Moerbeek M., Timmerman D., Van Huffel S., et al. (2015). A simulation study of sample size demonstrated the importance of the number of events per variable to develop prediction models in clustered data. J. Clin. Epidemiol. 68, 1406–1414. 10.1016/j.jclinepi.2015.02.002
    1. Zhang X., Li M., Chen S., Hu J., Guo Q., Liu R., et al. (2018). Endoscopic screening in asian countries is associated with reduced gastric cancer mortality: A meta-analysis and systematic review. Gastroenterology 155, 347–354. 10.1053/j.gastro.2018.04.026
    1. Zhu S. G., Qian Y. Y., Tang X. Y., Zhu Q. Q., Zhou W., Du H., et al. (2018). Gastric preparation for magnetically controlled capsule endoscopy: A prospective, randomized single-blinded controlled trial. Dig. Liver Dis. 50, 42–47. 10.1016/j.dld.2017.09.129
    1. Zou W. B., Hou X. H., Xin L., Liu J., Bo L. M., Yu G. Y., et al. (2015). Magnetic-controlled capsule endoscopy vs. gastroscopy for gastric diseases: A two-center self-controlled comparative trial. Endoscopy 47, 525–528. 10.1055/s-0034-1391123

Source: PubMed

3
Subscribe