Accuracy of Fitbit Devices: Systematic Review and Narrative Syntheses of Quantitative Data

Lynne M Feehan, Jasmina Geldman, Eric C Sayre, Chance Park, Allison M Ezzat, Ju Young Yoo, Clayon B Hamilton, Linda C Li, Lynne M Feehan, Jasmina Geldman, Eric C Sayre, Chance Park, Allison M Ezzat, Ju Young Yoo, Clayon B Hamilton, Linda C Li

Abstract

Background: Although designed as a consumer product to help motivate individuals to be physically active, Fitbit activity trackers are becoming increasingly popular as measurement tools in physical activity and health promotion research and are also commonly used to inform health care decisions.

Objective: The objective of this review was to systematically evaluate and report measurement accuracy for Fitbit activity trackers in controlled and free-living settings.

Methods: We conducted electronic searches using PubMed, EMBASE, CINAHL, and SPORTDiscus databases with a supplementary Google Scholar search. We considered original research published in English comparing Fitbit versus a reference- or research-standard criterion in healthy adults and those living with any health condition or disability. We assessed risk of bias using a modification of the Consensus-Based Standards for the Selection of Health Status Measurement Instruments. We explored measurement accuracy for steps, energy expenditure, sleep, time in activity, and distance using group percentage differences as the common rubric for error comparisons. We conducted descriptive analyses for frequency of accuracy comparisons within a ±3% error in controlled and ±10% error in free-living settings and assessed for potential bias of over- or underestimation. We secondarily explored how variations in body placement, ambulation speed, or type of activity influenced accuracy.

Results: We included 67 studies. Consistent evidence indicated that Fitbit devices were likely to meet acceptable accuracy for step count approximately half the time, with a tendency to underestimate steps in controlled testing and overestimate steps in free-living settings. Findings also suggested a greater tendency to provide accurate measures for steps during normal or self-paced walking with torso placement, during jogging with wrist placement, and during slow or very slow walking with ankle placement in adults with no mobility limitations. Consistent evidence indicated that Fitbit devices were unlikely to provide accurate measures for energy expenditure in any testing condition. Evidence from a few studies also suggested that, compared with research-grade accelerometers, Fitbit devices may provide similar measures for time in bed and time sleeping, while likely markedly overestimating time spent in higher-intensity activities and underestimating distance during faster-paced ambulation. However, further accuracy studies are warranted. Our point estimations for mean or median percentage error gave equal weighting to all accuracy comparisons, possibly misrepresenting the true point estimate for measurement bias for some of the testing conditions we examined.

Conclusions: Other than for measures of steps in adults with no limitations in mobility, discretion should be used when considering the use of Fitbit devices as an outcome measurement tool in research or to inform health care decisions, as there are seemingly a limited number of situations where the device is likely to provide accurate measurement.

Keywords: Fitbit; accuracy; data accuracy; distance; energy expenditure; energy metabolism; fitness trackers; review; sleep; steps; systematic review; time in activity; wearable activity tracker.

Conflict of interest statement

Conflicts of Interest: None declared.

©Lynne M Feehan, Jasmina Geldman, Eric C Sayre, Chance Park, Allison M Ezzat, Ju Young Yoo, Clayon B Hamilton, Linda C Li. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 09.08.2018.

Figures

Figure 1
Figure 1
Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) flow chart.
Figure 2
Figure 2
Percentage error distribution by sample size. Top: Step count in controlled settings. The blue oval indicates extreme outliers (n=4 comparisons). Bottom: Energy expenditure in controlled settings. Solid blue lines indicate mean error estimation. Dotted blue lines indicate 95% CI.
Figure 3
Figure 3
Step count percentage error in controlled settings. Speed (jog, normal, self-paced, slow, very slow) by body placement (torso, wrist, ankle) of the Fitbit device. Dark lines indicate mean (horizontal). Dashed lines indicate median (horizontal). Gray shading indicates ±3% measurement error.
Figure 4
Figure 4
Step count percentage error in controlled settings. Body placement (torso, wrist, ankle) of the Fitbit device by speed (jog, normal, self-paced, slow, very slow). Dark lines indicate mean (horizontal). Dashed lines indicate median (horizontal). Gray shading indicates ±3% measurement error.
Figure 5
Figure 5
Step count percentage error in controlled settings. Body motion (normal, constrained, exaggerated, variable) by speed (jog, normal, self-paced, slow, very slow). Dark lines indicate mean (horizontal). Dashed lines indicate median (horizontal).
Figure 6
Figure 6
Energy expenditure percentage error in controlled settings. Activity versus rest by body placement (torso, wrist). Dark lines indicate mean (horizontal). Dashed lines indicate median (horizontal). Triangles indicate measurement by direct calorimetry. Gray shading indicates ±3% measurement error.
Figure 7
Figure 7
Energy expenditure percentage error in controlled settings. Body placement (torso, wrist) by speed (jog, normal, self-paced, slow, very slow). Dark lines indicate mean (horizontal). Dashed lines indicate median (horizontal). Triangles indicate measurement by direct calorimetry. Gray shading indicates ±3% measurement error.
Figure 8
Figure 8
Energy expenditure percentage error in controlled settings. Speed (jog, normal, slow, self-paced, very slow) by body placement (torso, wrist). Dark lines indicate mean (horizontal). Dashed lines indicate median (horizontal). Triangles indicate measurement by direct calorimetry. Gray shading indicates ±3% measurement error.
Figure 9
Figure 9
Energy expenditure percentage error in controlled settings. Motion limitations (normal, constrained, exaggerated, variable) by speed (jog, normal, self-paced, slow, very slow). Dark lines indicate mean (horizontal). Dashed lines indicate median (horizontal). Triangles indicate measurement by direct calorimetry. Gray shading indicates ±3% measurement error.
Figure 10
Figure 10
Energy expenditure percentage error in controlled settings. Type of ambulation (continuous no incline, continuous incline, intermittent) by body placement (torso, wrist). Dark lines indicate mean (horizontal). Dashed lines indicate median (horizontal). Triangles indicate measurement by direct calorimetry. Gray shading indicates ±3% measurement error.

References

    1. Wearable tech: leveraging canadian innovation to improve health. 2014. [2018-03-14]. MaRS Mark Insights .
    1. Fitbit Reports $571M Q4’17 and $1.616B FY’17 Revenue. ; 2018. Feb 26, [2018-08-01]. .
    1. Bunn JA, Navalta JW, Fountaine CJ, Reece JD. Current state of commercial wearable technology in physical activity monitoring 2015-2017. Int J Exerc Sci. 2018;11(7):503–515.
    1. Mercer K, Li M, Giangregorio L, Burns C, Grindrod K. Behavior change techniques present in wearable activity trackers: a critical analysis. JMIR Mhealth Uhealth. 2016 Apr 27;4(2):e40. doi: 10.2196/mhealth.4461.
    1. Mishra A, Nieto A, Kitsiou S. Systematic review of mHealth interventions involving Fitbit activity tracking devices. IEEE International Conference on Healthcare Informatics; Aug 23-26, 2017; Park City, UT, USA. 2017.
    1. Noah B, Keller MS, Mosadeghi S, Stein L, Johl S, Delshad S, Tashjian VC, Lew D, Kwan JT, Jusufagic A, Spiegel BMR. Impact of remote patient monitoring on clinical outcomes: an updated meta-analysis of randomized controlled trials. npj Digit Med. 2018 Jan 15;1(1) doi: 10.1038/s41746-017-0002-4.
    1. Phillips SM, Cadmus-Bertram L, Rosenberg D, Buman MP, Lynch BM. Wearable technology and physical activity in chronic disease: opportunities and challenges. Am J Prev Med. 2018 Jan;54(1):144–150. doi: 10.1016/j.amepre.2017.08.015.
    1. US National Library of Medicine . [2018-08-01].
    1. Vooijs M, Alpay LL, Snoeck-Stroband JB, Beerthuizen T, Siemonsma PC, Abbink JJ, Sont JK, Rövekamp TA. Validity and usability of low-cost accelerometers for internet-based self-monitoring of physical activity in patients with chronic obstructive pulmonary disease. Interact J Med Res. 2014;3(4):e14. doi: 10.2196/ijmr.3056.
    1. Rosenberg D, Kadokura EA, Bouldin ED, Miyawaki CE, Higano CS, Hartzler AL. Acceptability of Fitbit for physical activity tracking within clinical care among men with prostate cancer. AMIA Annu Symp Proc. 2016;2016:1050–1059.
    1. Evenson KR, Goto MM, Furberg RD. Systematic review of the validity and reliability of consumer-wearable activity trackers. Int J Behav Nutr Phys Act. 2015 Dec 18;12:159. doi: 10.1186/s12966-015-0314-1.
    1. Wong CK, Mentis HM, Kuber R. The bit doesn't fit: Evaluation of a commercial activity-tracker at slower walking speeds. Gait Posture. 2018 Jan;59:177–181. doi: 10.1016/j.gaitpost.2017.10.010.
    1. O'Connell S, ÓLaighin G, Quinlan LR. When a step is not a step! Specificity analysis of five physical activity monitors. PLoS One. 2017;12(1):e0169616. doi: 10.1371/journal.pone.0169616.
    1. Dixon PM, Saint-Maurice PF, Kim Y, Hibbing P, Bai Y, Welk GJ. A primer on the use of equivalence testing for evaluating measurement agreement. Med Sci Sports Exerc. 2018 Apr;50(4):837–845. doi: 10.1249/MSS.0000000000001481.
    1. Mokkink LB, Terwee CB, Patrick DL, Alonso J, Stratford PW, Knol DL, Bouter LM, de Vet HCW. The COSMIN checklist for assessing the methodological quality of studies on measurement properties of health status measurement instruments: an international Delphi study. Qual Life Res. 2010 May;19(4):539–49. doi: 10.1007/s11136-010-9606-8.
    1. Terwee CB, Mokkink LB, Knol DL, Ostelo RWJG, Bouter LM, de Vet HCW. Rating the methodological quality in systematic reviews of studies on measurement properties: a scoring system for the COSMIN checklist. Qual Life Res. 2012 May;21(4):651–7. doi: 10.1007/s11136-011-9960-1.
    1. Popay J, Roberts H, Sowden A, Petticrew M, Arai L, Rodgers M, Britten N, Roen K, Duffy S. Guidance on the Conduct of Narrative Synthesis in Systematic Reviews. A Product From the ESRC Methods Programme. Version 1: April 2006. Lancaster, UK: Lancaster University; 2006. Apr,
    1. Campbell M, Katikireddi S, Sowden A, McKenzie J, Thomson H. Improving Conduct and Reporting of Narrative Synthesis of Quantitative Data (ICONS-Quant): protocol for a mixed methods study to develop a reporting guideline. BMJ Open. 2018 Feb;8(2):e020064.
    1. Bassett DR, Mahar MT, Rowe DA, Morrow JR. Walking and measurement. Med Sci Sports Exerc. 2008 Jul;40(7 Suppl):S529–36. doi: 10.1249/MSS.0b013e31817c699c.
    1. Schneider PL, Crouter SE, Lukajic O, Bassett DR. Accuracy and reliability of 10 pedometers for measuring steps over a 400-m walk. Med Sci Sports Exerc. 2003 Oct;35(10):1779–84. doi: 10.1249/01.MSS.0000089342.96098.C4.
    1. Schneider PL, Crouter SE, Bassett DR. Pedometer measures of free-living physical activity: comparison of 13 models. Med Sci Sports Exerc. 2004 Feb;36(2):331–5. doi: 10.1249/01.MSS.0000113486.60548.E9.
    1. Tudor-Locke C, Sisson SB, Lee SM, Craig CL, Plotnikoff RC, Bauman A. Evaluation of quality of commercial pedometers. Can J Public Health. 2006;97 Suppl 1:S10–5, S10.
    1. Moher D, Liberati A, Tetzlaff J, Altman DG, PRISMA Group Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. Int J Surg. 2010;8(5):336–41. doi: 10.1016/j.ijsu.2010.02.007.
    1. Balto JM, Kinnett-Hopkins DL, Motl RW. Accuracy and precision of smartphone applications and commercially available motion sensors in multiple sclerosis. Mult Scler J Exp Transl Clin. 2016;2:2055217316634754. doi: 10.1177/2055217316634754.
    1. Battenberg AK, Donohoe S, Robertson N, Schmalzried TP. The accuracy of personal activity monitoring devices. Semin Arthroplasty. 2017 Jun;28(2):71–75. doi: 10.1053/j.sart.2017.07.006.
    1. Beevi FHA, Miranda J, Pedersen CF, Wagner S. An evaluation of commercial pedometers for monitoring slow walking speed populations. Telemed J E Health. 2016 May;22(5):441–449. doi: 10.1089/tmj.2015.0120.
    1. Chen M, Kuo C, Pellegrini CA, Hsu M. Accuracy of wristband activity monitors during ambulation and activities. Med Sci Sports Exerc. 2016 Dec;48(10):1942–9. doi: 10.1249/MSS.0000000000000984.
    1. Chow JJ, Thom JM, Wewege MA, Ward RE, Parmenter BJ. Accuracy of step count measured by physical activity monitors: the effect of gait speed and anatomical placement site. Gait Posture. 2017 Sep;57:199–203. doi: 10.1016/j.gaitpost.2017.06.012.
    1. Diaz KM, Krupka DJ, Chang MJ, Shaffer JA, Ma Y, Goldsmith J, Schwartz JE, Davidson KW. Validation of the Fitbit One® for physical activity measurement at an upper torso attachment site. BMC Res Notes. 2016 Apr 12;9:213. doi: 10.1186/s13104-016-2020-8.
    1. Floegel TA, Florez-Pregonero A, Hekler EB, Buman MP. Validation of consumer-based hip and wrist activity monitors in older adults with varied ambulatory abilities. J Gerontol A Biol Sci Med Sci. 2017 Feb;72(2):229–236. doi: 10.1093/gerona/glw098.
    1. Fokkema T, Kooiman TJM, Krijnen WP. Reliability and validity of ten consumer activity trackers depend on walking speed. Med Sci Sports Exerc. 2017 Apr;49(4):793–800. doi: 10.1249/MSS.0000000000001146.
    1. Fulk GD, Combs SA, Danks KA, Nirider CD, Raja B, Reisman DS. Accuracy of 2 activity monitors in detecting steps in people with stroke and traumatic brain injury. Phys Ther. 2014 Feb;94(2):222–9. doi: 10.2522/ptj.20120525.
    1. Huang Y, Xu J, Yu B, Shull PB. Validity of FitBit, Jawbone UP, Nike+ and other wearable devices for level and stair walking. Gait Posture. 2016 Dec;48:36–41. doi: 10.1016/j.gaitpost.2016.04.025.
    1. Imboden MT, Nelson MB, Kaminsky LA, Montoye AH. Comparison of four Fitbit and Jawbone activity monitors with a research-grade ActiGraph accelerometer for estimating physical activity and energy expenditure. Br J Sports Med. 2017 May 08; doi: 10.1136/bjsports-2016-096990.
    1. Klassen TD, Simpson LA, Lim SB, Louie DR, Parappilly B, Sakakibara BM, Zbogar D, Eng JJ. “Stepping up” activity poststroke: ankle-positioned accelerometer can accurately record steps during slow walking. Phys Ther. 2016 Mar;96(3):355–60. doi: 10.2522/ptj.20140611.
    1. Kooiman TJM, Dontje ML, Sprenger SR, Krijnen WP, van der Schans CP, de Groot M. Reliability and validity of ten consumer activity trackers. BMC Sports Sci Med Rehabil. 2015;7:24. doi: 10.1186/s13102-015-0018-5.
    1. Nelson MB, Kaminsky LA, Dickin DC, Montoye AHK. Validity of consumer-based physical activity monitors for specific activity types. Med Sci Sports Exerc. 2016 Aug;48(8):1619–28. doi: 10.1249/MSS.0000000000000933.
    1. Modave F, Guo Y, Bian J, Gurka MJ, Parish A, Smith MD, Lee AM, Buford TW. Mobile device accuracy for step counting across age groups. JMIR Mhealth Uhealth. 2017 Jun 28;5(6):e88. doi: 10.2196/mhealth.7870.
    1. Montes J, Young JC, Tandy R, Navalta JW. Fitbit Flex: energy expenditure and step count evaluation. J Exerc Physiol Online. 2017 Oct;20(5):134–40.
    1. O'Connell S, ÓLaighin G, Kelly L, Murphy E, Beirne S, Burke N, Kilgannon O, Quinlan LR. These shoes are made for walking: sensitivity performance evaluation of commercial activity monitors under the expected conditions and circumstances required to achieve the international daily step goal of 10,000 steps. PLoS One. 2016;11(5):e0154956. doi: 10.1371/journal.pone.0154956.
    1. Park W, Lee VJ, Ku B, Tanaka H. Effect of walking speed and placement position interactions in determining the accuracy of various newer pedometers. J Exerc Sci Fit. 2014 Jun;12(1):31–37. doi: 10.1016/j.jesf.2014.01.003.
    1. Paul SS, Tiedemann A, Hassett LM, Ramsay E, Kirkham C, Chagpar S, Sherrington C. Validity of the Fitbit activity tracker for measuring steps in community-dwelling older adults. BMJ Open Sport Exerc Med. 2015;1(1):e000013. doi: 10.1136/bmjsem-2015-000013.
    1. Phillips LJ, Petroski GF, Markis NE. A comparison of accelerometer accuracy in older adults. Res Gerontol Nurs. 2015;8(5):213–9. doi: 10.3928/19404921-20150429-03.
    1. Schaffer SD, Holzapfel SD, Fulk G, Bosch PR. Step count accuracy and reliability of two activity tracking devices in people after stroke. Physiother Theory Pract. 2017 Oct;33(10):788–796. doi: 10.1080/09593985.2017.1354412.
    1. Simpson LA, Eng JJ, Klassen TD, Lim SB, Louie DR, Parappilly B, Sakakibara BM, Zbogar D. Capturing step counts at slow walking speeds in older adults: comparison of ankle and waist placement of measuring device. J Rehabil Med. 2015 Oct 05;47(9):830–5. doi: 10.2340/16501977-1993.
    1. Stackpool CM, Porcari JP, Mikat RP, Gillette C, Foster C. The accuracy of various activity trackers in estimating steps taken and energy expenditure. J Fit Res. 2014 Dec;3(3):32–48.
    1. Sushames A, Edwards A, Thompson F, McDermott R, Gebel K. Validity and reliability of fitbit flex for step count, moderate to vigorous physical activity and activity energy expenditure. PLoS One. 2016;11(9):e0161224. doi: 10.1371/journal.pone.0161224.
    1. Takacs J, Pollock CL, Guenther JR, Bahar M, Napier C, Hunt MA. Validation of the Fitbit One activity monitor device during treadmill walking. J Sci Med Sport. 2014 Sep;17(5):496–500. doi: 10.1016/j.jsams.2013.10.241.
    1. Treacy D, Hassett L, Schurr K, Chagpar S, Paul SS, Sherrington C. Validity of different activity monitors to count steps in an inpatient rehabilitation setting. Phys Ther. 2017 May 01;97(5):581–588. doi: 10.1093/ptj/pzx010.
    1. Steffen TM, Hacker TA, Mollinger L. Age- and gender-related test performance in community-dwelling elderly people: Six-Minute Walk Test, Berg Balance Scale, Timed Up & Go Test, and gait speeds. Phys Ther. 2002 Feb;82(2):128–37.
    1. Fritz S, Lusardi M. White paper: “walking speed: the sixth vital sign”. J Geriatr Phys Ther. 2009;32(2):46–9.
    1. Alharbi M, Bauman A, Neubeck L, Gallagher R. Validation of Fitbit-Flex as a measure of free-living physical activity in a community-based phase III cardiac rehabilitation population. Eur J Prev Cardiol. 2016 Sep;23(14):1476–1485. doi: 10.1177/2047487316634883.
    1. Brewer W, Swanson BT, Ortiz A. Validity of Fitbit's active minutes as compared with a research-grade accelerometer and self-reported measures. BMJ Open Sport Exerc Med. 2017;3(1):e000254. doi: 10.1136/bmjsem-2017-000254.
    1. Dominick GM, Winfree KN, Pohlig RT, Papas MA. Physical activity assessment between consumer- and research-grade accelerometers: a comparative study in free-living conditions. JMIR Mhealth Uhealth. 2016 Sep 19;4(3):e110. doi: 10.2196/mhealth.6281.
    1. Farina N, Lowry RG. The validity of consumer-level activity monitors in healthy older adults in free-living conditions. J Aging Phys Act. 2018 Jan 01;26(1):128–135. doi: 10.1123/japa.2016-0344.
    1. Ferguson T, Rowlands AV, Olds T, Maher C. The validity of consumer-level, activity monitors in healthy adults worn in free-living conditions: a cross-sectional study. Int J Behav Nutr Phys Act. 2015;12:42. doi: 10.1186/s12966-015-0201-9.
    1. Gomersall SR, Ng N, Burton NW, Pavey TG, Gilson ND, Brown WJ. Estimating physical activity and sedentary behavior in a free-living context: a pragmatic comparison of consumer-based activity trackers and ActiGraph accelerometry. J Med Internet Res. 2016 Sep 07;18(9):e239.
    1. Hargens TA, Deyarmin KN, Snyder KM, Mihalik AG, Sharpe LE. Comparison of wrist-worn and hip-worn activity monitors under free living conditions. J Med Eng Technol. 2017 Apr;41(3):200–207. doi: 10.1080/03091902.2016.1271046.
    1. Hui J, Heyden R, Bao T, Accettone N, McBay C, Richardson J, Tang A. Validity of the Fitbit One for measuring activity in community-dwelling stroke survivors. Physiother Can. 2018;70(1):81–89. doi: 10.3138/ptc.2016-40.ep.
    1. Middelweerd A, Van Der Ploeg HP, Van Halteren A, Twisk JWR, Brug J, Te Velde SJ. A validation study of the Fitbit One in daily life using different time intervals. Med Sci Sports Exerc. 2017 Jun;49(6):1270–1279. doi: 10.1249/MSS.0000000000001225.
    1. Reid RER, Insogna JA, Carver TE, Comptour AM, Bewski NA, Sciortino C, Andersen RE. Validity and reliability of Fitbit activity monitors compared to ActiGraph GT3X+ with female adults in a free-living environment. J Sci Med Sport. 2017 Jun;20(6):578–582. doi: 10.1016/j.jsams.2016.10.015.
    1. Thorup CB, Andreasen JJ, Sørensen EE, Grønkjær M, Dinesen BI, Hansen J. Accuracy of a step counter during treadmill and daily life walking by healthy adults and patients with cardiac disease. BMJ Open. 2017 Dec 31;7(3):e011742. doi: 10.1136/bmjopen-2016-011742.
    1. Van Blarigan EL, Kenfield SA, Tantum L, Cadmus-Bertram LA, Carroll PR, Chan JM. The Fitbit One physical activity tracker in men with prostate cancer: validation study. JMIR Cancer. 2017 Apr 18;3(1):e5. doi: 10.2196/cancer.6935.
    1. An HS, Jones GC, Kang SK, Welk GJ, Lee JM. How valid are wearable physical activity trackers for measuring steps? Eur J Sport Sci. 2017 Apr;17(3):360–368. doi: 10.1080/17461391.2016.1255261.
    1. Chu AHY, Ng SHX, Paknezhad M, Gauterin A, Koh D, Brown MS, Müller-Riemenschneider F. Comparison of wrist-worn Fitbit Flex and waist-worn ActiGraph for measuring steps in free-living adults. PLoS One. 2017;12(2):e0172535. doi: 10.1371/journal.pone.0172535.
    1. Rosenberger ME, Buman MP, Haskell WL, McConnell MV, Carstensen LL. 24 hours of sleep, sedentary behavior, and physical activity with nine wearable devices. Med Sci Sports Exerc. 2016 Mar;48(3):457–465. doi: 10.1249/MSS.0000000000000778.
    1. Tully MA, McBride C, Heron L, Hunter RF. The validation of Fibit Zip™ physical activity monitor as a measure of free-living physical activity. BMC Res Notes. 2014;7:952. doi: 10.1186/1756-0500-7-952.
    1. Adam NJ, Spierer DK, Gu J, Bronner S. Comparison of steps and energy expenditure assessment in adults of Fitbit Tracker and Ultra to the Actical and indirect calorimetry. J Med Eng Technol. 2013 Oct;37(7):456–62. doi: 10.3109/03091902.2013.831135.
    1. Bai Y, Welk GJ, Nam YH, Lee JA, Lee J, Kim Y, Meier NF, Dixon PM. Comparison of consumer and research monitors under semistructured settings. Med Sci Sports Exerc. 2016 Jan;48(1):151–158. doi: 10.1249/MSS.0000000000000727.
    1. Chowdhury EA, Western MJ, Nightingale TE, Peacock OJ, Thompson D. Assessment of laboratory and daily energy expenditure estimates from consumer multi-sensor physical activity monitors. PLoS One. 2017;12(2):e0171720. doi: 10.1371/journal.pone.0171720.
    1. Dannecker KL, Sazonova NA, Melanson EL, Sazonov ES, Browning RC. A comparison of energy expenditure estimation of several physical activity monitors. Med Sci Sports Exerc. 2013 Nov;45(11):2105–12. doi: 10.1249/MSS.0b013e318299d2eb.
    1. Dondzila C, Garner D. Comparative accuracy of fitness tracking modalities in quantifying energy expenditure. J Med Eng Technol. 2016 Aug;40(6):325–9. doi: 10.1080/03091902.2016.1197978.
    1. Dooley EE, Golaszewski NM, Bartholomew JB. Estimating accuracy at exercise intensities: a comparative study of self-monitoring heart rate and physical activity wearable devices. JMIR Mhealth Uhealth. 2017 Mar 16;5(3):e34. doi: 10.2196/mhealth.7043.
    1. Gusmer RJ, Bosch TA, Watkins AN, Ostrem JD, Dengel DR. Comparison of FitBit® Ultra to ActiGraphTM GT1M for assessment of physical activity in young adults during treadmill walking. Open Sports Med J. 2014 Apr 04;8(1):11–15. doi: 10.2174/1874387001408010011.
    1. Lee J, Kim Y, Welk GJ. Validity of consumer-based physical activity monitors. Med Sci Sports Exerc. 2014 Sep;46(9):1840–8. doi: 10.1249/MSS.0000000000000287.
    1. Montoye AHK, Mitrzyk JR, Molesky MJ. Comparative accuracy of a wrist-worn activity tracker and a smart shirt for physical activity assessment. Meas Phys Educ Exerc Sci. 2017 Jun 08;21(4):201–211. doi: 10.1080/1091367X.2017.1331166.
    1. Murakami H, Kawakami R, Nakae S, Nakata Y, Ishikawa-Takata K, Tanaka S, Miyachi M. Accuracy of wearable devices for estimating total energy expenditure: comparison with metabolic chamber and doubly labeled water method. JAMA Intern Med. 2016 Dec 01;176(5):702–3. doi: 10.1001/jamainternmed.2016.0152.
    1. Price K, Bird SR, Lythgo N, Raj IS, Wong JYL, Lynch C. Validation of the Fitbit One, Garmin Vivofit and Jawbone UP activity tracker in estimation of energy expenditure during treadmill walking and running. J Med Eng Technol. 2017 Apr;41(3):208–215. doi: 10.1080/03091902.2016.1253795.
    1. Sasaki JE, Hickey A, Mavilia M, Tedesco J, John D, Kozey KS, Freedson PS. Validation of the Fitbit wireless activity tracker for prediction of energy expenditure. J Phys Act Health. 2015 Feb;12(2):149–54. doi: 10.1123/jpah.2012-0495.
    1. Wallen MP, Gomersall SR, Keating SE, Wisløff U, Coombes JS. Accuracy of heart rate watches: implications for weight management. PLoS One. 2016;11(5):e0154420. doi: 10.1371/journal.pone.0154420.
    1. Brooke SM, An H, Kang S, Noble JM, Berg KE, Lee J. Concurrent validity of wearable activity trackers under free-living conditions. J Strength Cond Res. 2017 Apr;31(4):1097–1106. doi: 10.1519/JSC.0000000000001571.
    1. Cook JD, Prairie ML, Plante DT. Utility of the Fitbit Flex to evaluate sleep in major depressive disorder: a comparison against polysomnography and wrist-worn actigraphy. J Affect Disord. 2017 Aug 01;217:299–305. doi: 10.1016/j.jad.2017.04.030.
    1. Mantua J, Gravel N, Spencer RMC. Reliability of sleep measures from four personal health monitoring devices compared to research-based actigraphy and polysomnography. Sensors (Basel) 2016 Dec 05;16(5) doi: 10.3390/s16050646.
    1. Montgomery-Downs HE, Insana SP, Bond JA. Movement toward a novel activity monitoring device. Sleep Breath. 2012 Sep;16(3):913–7. doi: 10.1007/s11325-011-0585-y.
    1. Lee H, Lee H, Moon J, Lee T, Kim M, In H, Cho C, Kim L. Comparison of wearable activity tracker with actigraphy for sleep evaluation and circadian rest-activity rhythm measurement in healthy young adults. Psychiatry Investig. 2017 Mar;14(2):179–185. doi: 10.4306/pi.2017.14.2.179.
    1. Dickinson DL, Cazier J, Cech T. A practical validation study of a commercial accelerometer using good and poor sleepers. Health Psychol Open. 2016 Jul;3(2):2055102916679012. doi: 10.1177/2055102916679012.
    1. Wahl Y, Düking P, Droszez A, Wahl P, Mester J. Criterion-validity of commercially available physical activity tracker to estimate step count, covered distance and energy expenditure during sports conditions. Front Physiol. 2017;8:725. doi: 10.3389/fphys.2017.00725. doi: 10.3389/fphys.2017.00725.
    1. Li LC, Sayre EC, Xie H, Falck RS, Best JR, Liu-Ambrose T, Grewal N, Hoens AM, Noonan G, Feehan LM. Efficacy of a community-based technology-enabled physical activity counselling program for people with knee osteoarthritis: a proof-of-concept study. J Med Internet Res. 2018 Apr 30;20(4):e159. doi: 10.2196/jmir.8514.
    1. Li LC, Feehan LM, Shaw C, Xie H, Sayre EC, Aviña-Zubeita A, Grewal N, Townsend AF, Gromala D, Noonan G, Backman CL. A technology-enabled counselling program versus a delayed treatment control to support physical activity participation in people with inflammatory arthritis: study protocol for the OPAM-IA randomized controlled trial. BMC Rheumatol. 2017 Nov 28;1(1) doi: 10.1186/s41927-017-0005-4.
    1. Li LC, Sayre EC, Xie H, Clayton C, Feehan LM. A community-based physical activity counselling program for people with knee osteoarthritis: feasibility and preliminary efficacy of the Track-OA Study. JMIR Mhealth Uhealth. 2017 Jun 26;5(6):e86. doi: 10.2196/mhealth.7863.
    1. Henriksen A, Haugen MM, Woldaregay AZ, Muzny M, Hartvigsen G, Hopstock LA, Grimsgaard S. Using fitness trackers and smartwatches to measure physical activity in research: analysis of consumer wrist-worn wearables. J Med Internet Res. 2018 Mar 22;20(3):e110. doi: 10.2196/jmir.9157.

Source: PubMed

3
Subscribe