Comparison of the McGrath videolaryngoscope and the Macintosh laryngoscope for double lumen endobronchial tube intubation in patients with manual in-line stabilization: A randomized controlled trial

Ji Young Yoo, Sung Yong Park, Jong Yeop Kim, Myungseob Kim, Seok Jin Haam, Dae Hee Kim, Ji Young Yoo, Sung Yong Park, Jong Yeop Kim, Myungseob Kim, Seok Jin Haam, Dae Hee Kim

Abstract

Background: Double lumen endobronchial tube (DLT) intubation is commonly used for one-lung ventilation in thoracic surgery. However, because of its large size and shape, it is difficult to perform intubation compared with a single lumen tube. The aim of this randomized controlled trial was to determine whether the McGrath videolaryngoscope has any advantage over the direct Macintosh laryngoscope for DLT intubation in patients with a simulated difficult airway.

Methods: Forty-four patients (19-60 years of age); scheduled to undergo general anesthesia with one-lung ventilation were assigned to 1 of 2 groups: DLT intubation with the McGrath videolaryngoscope (ML group [n = 22]); or conventional Macintosh laryngoscope (DL group [n = 22]). After manual in-line stabilization was applied as a way of simulating a difficult airway, the time required for intubation and the quality of glottic view were evaluated.

Results: The time to successful intubation was not different between the 2 groups (ML group, 45 s [interquartile range, 38-52 s] versus DL group, 54 s [45-59 s]; P = .089). The McGrath videolaryngoscope, however, provided a significantly better glottic view. Modified Cormack and Lehane grade was better (P < .001), and the percentage of glottis opening score was higher in the ML group (P < .001). Overall intubation difficulty scale score was lower in the ML group (1 [0-2]) versus the DL group (3 [2-4]) (P < .001).

Conclusion: The McGrath videolaryngoscope improved glottic view and resulted in lower overall intubation difficulty scale score in patients with in-line stabilization.

Conflict of interest statement

The authors have no conflicts of interest to disclose.

Figures

Figure 1
Figure 1
CONSORT flow diagram of recruitment and assessment of study participants.

References

    1. Rai MR, Dering A, Verghese C. The Glidescope system: a clinical assessment of performance. Anaesthesia 2005;60:60–4.
    1. Asai T. Videolaryngoscopes: do they truly have roles in difficult airways? Anesthesiology 2012;116:515–7.
    1. Asai T, Murao K, Shingu K. Training method of applying pressure on the neck for laryngoscopy: use of a videolaryngoscope. Anaesthesia 2003;58:602–3.
    1. Shippey B, Ray D, McKeown D. Case series: the McGrath videolaryngoscope—an initial clinical evaluation. Can J Anaesth 2007;54:307–13.
    1. Shippey B, Ray D, McKeown D. Use of the McGrath videolaryngoscope in the management of difficult and failed tracheal intubation. Br J Anaesth 2008;100:116–9.
    1. Byhahn C, Iber T, Zacharowski K, et al. Tracheal intubation using the mobile C-MAC video laryngoscope or direct laryngoscopy for patients with a simulated difficult airway. Minerva Anestesiol 2010;76:577–83.
    1. Enomoto Y, Asai T, Arai T, et al. Pentax-AWS, a new videolaryngoscope, is more effective than the Macintosh laryngoscope for tracheal intubation in patients with restricted neck movements: a randomized comparative study. Br J Anaesth 2008;100:544–8.
    1. McElwain J, Laffey JG. Comparison of the C-MAC(R), Airtraq(R), and Macintosh laryngoscopes in patients undergoing tracheal intubation with cervical spine immobilization. Br J Anaesth 2011;107:258–64.
    1. Liu EH, Goy RW, Tan BH, et al. Tracheal intubation with videolaryngoscopes in patients with cervical spine immobilization: a randomized trial of the Airway Scope and the GlideScope. Br J Anaesth 2009;103:446–51.
    1. Theiler L, Hermann K, Schoettker P, et al. SWIVIT—Swiss video-intubation trial evaluating video-laryngoscopes in a simulated difficult airway scenario: study protocol for a multicenter prospective randomized controlled trial in Switzerland. Trials 2013;14:94.
    1. Bathory I, Frascarolo P, Kern C, et al. Evaluation of the GlideScope for tracheal intubation in patients with cervical spine immobilisation by a semi-rigid collar. Anaesthesia 2009;64:1337–41.
    1. Taylor AM, Peck M, Launcelott S, et al. The McGrath(R) Series 5 videolaryngoscope vs the Macintosh laryngoscope: a randomised, controlled trial in patients with a simulated difficult airway. Anaesthesia 2013;68:142–7.
    1. Yao WL, Wan L, Xu H, et al. A comparison of the McGrath(R) Series 5 videolaryngoscope and Macintosh laryngoscope for double-lumen tracheal tube placement in patients with a good glottic view at direct laryngoscopy. Anaesthesia 2015;70:810–7.
    1. Yang M, Kim JA, Ahn HJ, et al. Double-lumen tube tracheal intubation using a rigid video-stylet: a randomized controlled comparison with the Macintosh laryngoscope. Br J Anaesth 2013;111:990–5.
    1. Hsu HT, Chou SH, Chen CL, et al. Left endobronchial intubation with a double-lumen tube using direct laryngoscopy or the Trachway(R) video stylet. Anaesthesia 2013;68:851–5.
    1. Kido H, Komasawa N, Matsunami S, et al. Comparison of McGRATH MAC and Macintosh laryngoscopes for double-lumen endotracheal tube intubation by anesthesia residents: a prospective randomized clinical trial. J Clin Anesth 2015;27:476–80.
    1. Purugganan RV, Jackson TA, Heir JS, et al. Video laryngoscopy versus direct laryngoscopy for double-lumen endotracheal tube intubation: a retrospective analysis. J Cardiothorac Vasc Anesth 2012;26:845–8.
    1. Lin W, Li H, Liu W, et al. A randomised trial comparing the CEL-100 videolaryngoscope(TM) with the Macintosh laryngoscope blade for insertion of double-lumen tubes. Anaesthesia 2012;67:771–6.
    1. Russell T, Slinger P, Roscoe A, et al. A randomised controlled trial comparing the GlideScope((R)) and the Macintosh laryngoscope for double-lumen endobronchial intubation. Anaesthesia 2013;68:1253–8.
    1. Poon KH, Liu EH. The Airway Scope for difficult double-lumen tube intubation. J Clin Anesth 2008;20:319.
    1. Hughes CG, Mathews L, Easdown J, et al. The McGrath video laryngoscope in unstable cervical spine surgery: a case series. J Clin Anesth 2010;22:575–6.
    1. Mallampati SR, Gatt SP, Gugino LD, et al. A clinical sign to predict difficult tracheal intubation: a prospective study. Can Anaesth Soc J 1985;32:429–34.
    1. Yentis SM, Lee DJ. Evaluation of an improved scoring system for the grading of direct laryngoscopy. Anaesthesia 1998;53:1041–4.
    1. Ochroch EA, Hollander JE, Kush S, et al. Assessment of laryngeal view: percentage of glottic opening score vs Cormack and Lehane grading. Can J Anaesth 1999;46:987–90.
    1. Adnet F, Borron SW, Racine SX, et al. The intubation difficulty scale (IDS): proposal and evaluation of a new score characterizing the complexity of endotracheal intubation. Anesthesiology 1997;87:1290–7.
    1. Campos JH, Hallam EA, Van Natta T, et al. Devices for lung isolation used by anesthesiologists with limited thoracic experience: comparison of double-lumen endotracheal tube, Univent torque control blocker, and Arndt wire-guided endobronchial blocker. Anesthesiology 2006;104:261–6. discussion 5A.
    1. O’Leary AM, Sandison MR, Myneni N, et al. Preliminary evaluation of a novel videolaryngoscope, the McGrath series 5, in the management of difficult and challenging endotracheal intubation. J Clin Anesth 2008;20:320–1.
    1. Noppens RR, Mobus S, Heid F, et al. Evaluation of the McGrath Series 5 videolaryngoscope after failed direct laryngoscopy. Anaesthesia 2010;65:716–20.
    1. Sun DA, Warriner CB, Parsons DG, et al. The GlideScope Video Laryngoscope: randomized clinical trial in 200 patients. Br J Anaesth 2005;94:381–4.
    1. van Zundert A, Maassen R, Lee R, et al. A Macintosh laryngoscope blade for videolaryngoscopy reduces stylet use in patients with normal airways. Anesth Analg 2009;109:825–31.
    1. Niforopoulou P, Pantazopoulos I, Demestiha T, et al. Video-laryngoscopes in the adult airway management: a topical review of the literature. Acta Anaesthesiol Scand 2010;54:1050–61.
    1. Xue FS, Zhang GH, Liu J, et al. The clinical assessment of glidescope in orotracheal intubation under general anesthesia. Minerva Anestesiol 2007;73:451–7.
    1. Pott LM, Murray WB. Review of video laryngoscopy and rigid fiberoptic laryngoscopy. Curr Opin Anaesthesiol 2008;21:750–8.
    1. Thong SY, Lim Y. Video and optic laryngoscopy assisted tracheal intubation—the new era. Anaesth Intensive Care 2009;37:219–33.
    1. Nolan JP, Wilson ME. Orotracheal intubation in patients with potential cervical spine injuries. An indication for the gum elastic bougie. Anaesthesia 1993;48:630–3.
    1. Thiboutot F, Nicole PC, Trepanier CA, et al. Effect of manual in-line stabilization of the cervical spine in adults on the rate of difficult orotracheal intubation by direct laryngoscopy: a randomized controlled trial. Can J Anaesth 2009;56:412–8.
    1. Wood PR. Direct laryngoscopy and cervical spine stabilisation. Anaesthesia 1994;49:77–8.

Source: PubMed

3
Subscribe