Does variability in automated perfusion software outputs for acute ischemic stroke matter? Reanalysis of EXTEND perfusion imaging

Andrew Bivard, Leonid Churilov, Henry Ma, Christopher Levi, Bruce Campbell, Nawaf Yassi, Atte Meretoja, Henry Zhao, Gagan Sharma, Chushuang Chen, Stephen Davis, Geoffrey Donnan, Bernard Yan, Mark Parsons, EXTEND investigators, Andrew Bivard, Leonid Churilov, Henry Ma, Christopher Levi, Bruce Campbell, Nawaf Yassi, Atte Meretoja, Henry Zhao, Gagan Sharma, Chushuang Chen, Stephen Davis, Geoffrey Donnan, Bernard Yan, Mark Parsons, EXTEND investigators

Abstract

Aims: We reprocessed the Extending the time for Thrombolysis in Emergency Neurological Deficits (EXTEND) perfusion imaging with a different automated software with the aim of comparing mismatch eligibility and outcomes.

Methods: EXTEND baseline perfusion imaging data were reprocessed using autoMIStar software to identify patients who were eligible based on the same target mismatch criteria as per the original trial.

Results: From the 225 patients fulfilling RAPID-based mismatch criteria randomized in the EXTEND study, 196 (87%) patients met the revised mismatch criteria. Most common reasons for not meeting revised criteria were core >70 ml (n = 9), and no perfusion lesion/lack of penumbral tissue (n = 20). The revised perfusion lesion volumes were significantly smaller compared to the original RAPID volumes (median 68 ml IQR 34-102 ml vs. 42 ml 16-92 ml, p = 0.036). Of the patients who met the revised mismatch criteria, 40% receiving alteplase had modified Rankin Scale (mRS) 0-1 at 3-month compared to 28% with placebo (Adjusted Odds Ratio (OR) = 2.23, CI 1.08-4.58, p = 0.028). In contrast, in the original mismatch cohort, 35% receiving alteplase had mRS 0-1 at 3-month compared to 30% with placebo (adjusted OR = 1.88, p = 0.056).

Conclusions: These data reinforce the benefit of alteplase in the later time window, and suggest that differences in automated perfusion imaging software outputs may be clinically relevant.

Trial registration: ClinicalTrials.gov NCT00887328 NCT01580839.

Keywords: CT perfusion; ischemic stroke; target mismatch; thrombolysis.

Conflict of interest statement

Dr. Davis, receiving advisory board fees from AstraZeneca and Boehringer Ingelheim; and Dr. Donnan, receiving advisory board fees from AstraZeneca Australia, Bayer, Boehringer Ingelheim, Merck, Pfizer, and Servier; Dr. Parsons reports receiving advisory board fees from Boehringer Ingelheim, and research partnerships with Canon Medical Systems, Apollo Medical Imaging, and Siemens. No other potential conflict of interest relevant to this article were reported.

© 2021 The Authors. CNS Neuroscience & Therapeutics Published by John Wiley & Sons Ltd.

Figures

FIGURE 1
FIGURE 1
Modified Rankin Scale Scores at 90 days of the participants meeting the revised target mismatch criteria in the EXTEND study. Patients in the rtPA group have improved functional outcome at 90 days

References

    1. Nogueira RG, Jadhav AP, Haussen DC, et al. Thrombectomy 6 to 24 Hours after Stroke with a Mismatch between Deficit and Infarct. N Engl J Med. 2018;378:11‐21.
    1. Albers GW, Marks MP, Kemp S, et al. Thrombectomy for stroke at 6 to 16 hours with selection by perfusion imaging. N Engl J Med. 2018;378:708‐718.
    1. Ma H, Campbell BCV, Parsons MW, et al. Thrombolysis guided by perfusion imaging up to 9 hours after onset of stroke. N Engl J Med. 2019;380:1795‐1803.
    1. Campbell BC, Christensen S, Levi CR, et al. Cerebral blood flow is the optimal CT perfusion parameter for assessing infarct core. Stroke; J Cereb Circ. 2011;42:3435‐3440.
    1. Bivard A, Spratt N, Levi C, Parsons M. Perfusion computer tomography: imaging and clinical validation in acute ischaemic stroke. Brain: J Neurol. 2011;134:3408‐3416.
    1. Bivard A, Levi C, Spratt N, Parsons M. Perfusion CT in acute stroke: a comprehensive analysis of infarct and penumbra. Radiology. 2013;267:543‐550.
    1. Lin L, Bivard A, Kleinig T, et al. Correction for delay and dispersion results in more accurate cerebral blood flow ischemic core measurement in acute stroke. Stroke; J Cereb Circ. 2018;49:924‐930.
    1. Campbell BC, Christensen S, Levi CR, et al. Comparison of computed tomography perfusion and magnetic resonance imaging perfusion‐diffusion mismatch in ischemic stroke. Stroke; J Cereb Circ. 2012;43:2648‐2653.
    1. Lin L, Bivard A, Levi CR, Parsons MW. Comparison of computed tomographic and magnetic resonance perfusion measurements in acute ischemic stroke: back‐to‐back quantitative analysis. Stroke; J Cereb Circ. 2014;45:1727‐1732.
    1. Garcia‐Esperon C, Bivard A, Levi C, Parsons M. Use of computed tomography perfusion for acute stroke in routine clinical practice: complex scenarios, mimics, and artifacts. Int J Stroke: Off J Int Stroke Soc. 2018;13:469‐472.
    1. Ma H, Parsons MW, Christensen S, et al. A multicentre, randomized, double‐blinded, placebo‐controlled Phase III study to investigate EXtending the time for Thrombolysis in Emergency Neurological Deficits (EXTEND). Int J Stroke: Off J Int Stroke Soc. 2012;7:74‐80.
    1. Lin L, Bivard A, Krishnamurthy V, Levi CR, Parsons MW. Whole‐brain CT perfusion to quantify acute ischemic penumbra and core. Radiology. 2016;279:876‐887.
    1. Bivard A, Levi C, Krishnamurthy V, et al. Perfusion computed tomography to assist decision making for stroke thrombolysis. Brain: J Neurol. 2015;138:1919‐1931.
    1. Lin L, Chen C, Tian H, et al. Perfusion computed tomography accurately quantifies collateral flow after acute ischemic stroke. Stroke; J Cereb Circ. 2020;51:1006‐1009.
    1. Cereda CW, Christensen S, Campbell BCV, et al. A benchmarking tool to evaluate computer tomography perfusion infarct core predictions against a DWI standard. J Cereb Blood Flow Metab: Off J Int Soc Cereb Blood Flow Metab. 2016;36:1780‐1789.
    1. Bivard A, Lou M, Levi CR, et al. Too good to treat? ischemic stroke patients with small computed tomography perfusion lesions may not benefit from thrombolysis. Ann Neurol. 2016;80:286‐293.
    1. Vagal A, Wintermark M, Nael K, et al. Automated CT perfusion imaging for acute ischemic stroke: pearls and pitfalls for real‐world use. Neurology. 2019;93:888‐898.
    1. Wintermark M, Albers GW, Broderick JP, et al. Acute stroke imaging research roadmap II. Stroke; J Cereb Circ. 2013;44:2628‐2639.
    1. Austein F, Riedel C, Kerby T, et al. Comparison of perfusion CT software to predict the final infarct volume after thrombectomy. Stroke; J Cereb Circ. 2016;47:2311‐2317.
    1. Rava RA, Snyder KV, Mokin M, et al. Assessment of computed tomography perfusion software in predicting spatial location and volume of infarct in acute ischemic stroke patients: a comparison of Sphere, Vitrea, and RAPID. J NeuroIntervent Surg. 2021;13:130‐135.

Source: PubMed

3
Subscribe