Tato stránka byla automaticky přeložena a přesnost překladu není zaručena. Podívejte se prosím na anglická verze pro zdrojový text.

Clinical Applications of Round Window Imaging Anatomy in Cochlear Implant Surgery

15. prosince 2014 aktualizováno: MICHAL.LUNTZ, Bnai Zion Medical Center

Clinical Applications of Round Window High Resolution Computerised Tomography Anatomy in Cochlear Implant Surgery

The purpose of this study is to measure the size of the round window niche and its relation to the mastoid segment of the facial nerve and the mastoid cortex, using high resolution computerized tomography of the temporal bone, in order to assess preoperatively what is the extent of obstruction of the round window membrane and whether there is a surgical possibility of round window approach in the insertion of electrode array into the cochlea

Přehled studie

Postavení

Neznámý

Intervence / Léčba

Detailní popis

The assessment of the anatomy of the round window will be executed using the stractured measuring software used for imaging of the Bnai Zion medical center (CARESTREAM PACS Ver. 11.0, CARSTREAM HEALTH INC.) in IAC window (centered at 700 with a total width of 4000) in the available zoom by the software (usually 400-800%).

Measuring the length (mm) and angle will be executed by the software's structured rulers.

Measuring protocol:

  1. Measured scans: one taken in an orbito-meatal plane
  2. Chosen slices: where both the round window niche and the external ear canal are seen on the same slice
  3. Distances measured:

    1. Distance 1: between the anterior edge of the round window niche and the cortex of the mastoid, with a minimal distance of 0.5mm to the posterior wall of the external ear canal
    2. Distance 2: between the posterior edge of the round window niche and the cortex of the mastoid, with a minimal distance of 0.3mm to the anterior edge of the mastoid segment of the facial nerve.
    3. Distance 3: the size of the round window niche (from its anterior to posterior edges)
    4. Distance 4: between the anterior (most medial) edge of the round window membrane to a point at least 0.3mm anterior to the mastoid segment of the facial nerve.
    5. Distance 5: between the posterior (most lateral) edge of the round window membrane to a point at least 0.3mm anterior to the mastoid segment of the facial nerve
    6. Distance 6: size of round window membrane (anterior/medial to posterior/lateral)
    7. Distance 7: between the lateral edges of distance 1 and 2 marking the cortical size of the "working channel" created between the lines (from the cortex to the round window).
  4. Angles measured:

    1. Between distance 1 and 7 - marking the angle of the "working channel" relatively to the cortex
    2. Between distance 1, passing in the middle of distance 3 to the middle of distance 6 - marking the angle of possible insertion from the working channel into the cochlea

Typ studie

Pozorovací

Zápis (Aktuální)

100

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní místa

      • Haifa, Izrael
        • Bnai Zion Medical Center

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

20 let a starší (Dospělý, Starší dospělý)

Přijímá zdravé dobrovolníky

Ne

Pohlaví způsobilá ke studiu

Všechno

Metoda odběru vzorků

Vzorek nepravděpodobnosti

Studijní populace

100 patient who were suffering from profound sensory neural hearing loss and underwent a high resolution computerized tomography of the temporal bone prior to cochlear implantation surgery

Popis

Inclusion Criteria:

  • age 20 years old or older
  • high resolution computerized tomography of the temporal bone (slices ≤1mm) before the surgery
  • on the measured slices both the round window niche and the posterior wall of the external ear canal are seen

Exclusion Criteria:

  • inner, middle or external ear malformation
  • temporal bone malformation
  • status post cochlear implant
  • status post temporal bone trauma
  • slices were the round window niche and the posterior wall of the external ear canal are not seen on the same slice

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

  • Observační modely: Pouze případ
  • Časové perspektivy: Retrospektivní

Kohorty a intervence

Skupina / kohorta
Intervence / Léčba
CT of the temporal bone

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Časové okno
the size of round window niche and its relation to the cochlea
Časové okno: january-june 2014 (six months)
january-june 2014 (six months)

Sekundární výstupní opatření

Měření výsledku
Časové okno
sizes of working channel from the mastoid cortex into the round window membrane and its relation to the mastoid sagment of the facial nerve
Časové okno: january-june 2014 (six months)
january-june 2014 (six months)

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Vyšetřovatelé

  • Vrchní vyšetřovatel: Michal Luntz, Prof., chair of otorhinolaryngology department at the Bnai Zion medical center

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia

1. ledna 2014

Primární dokončení (Očekávaný)

1. června 2015

Termíny zápisu do studia

První předloženo

20. března 2014

První předloženo, které splnilo kritéria kontroly kvality

20. března 2014

První zveřejněno (Odhad)

21. března 2014

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Odhad)

16. prosince 2014

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

15. prosince 2014

Naposledy ověřeno

1. prosince 2014

Více informací

Termíny související s touto studií

Další identifikační čísla studie

  • 0140-13-BNZ (Jiné číslo grantu/financování: TRADIS GAT LTD. ISRAEL)

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .

Předplatit