- ICH GCP
- Registr klinických studií v USA
- Klinická studie NCT03017599
Yield Rate for Procurement the Histologic Core With Endoscopic Ultrasound-guided Fine Needle Biopsy With 20-gauge Ultrasound Biopsy Needles for Solid Pancreatic Masses: Pilot Study
Přehled studie
Postavení
Intervence / Léčba
Detailní popis
Pancreatic ductal adenocarcinoma is the fourth cause of death in the Western world. Surgery remains the only treatment offering an advantage in terms of overall survival (5-year survival range, 15-25%), but unfortunately only 10-20% of patients present resectable disease at the time of diagnosis.
Regarding the diagnosis of pancreatic cancer, proper tool with high diagnostic yield is very important. The investigators investigated the technical feasibility and diagnostic yield of recent-developed new 20-gauge Procore needle for EUS-guided fine needle biopsy in pancreatic solid lesions.
The investigators applied the 20-gauge procore needle for EUS-guided fine needle biopsy in the diagnosis of pancreatic solid mass. A total of 30 patients will be enrolled for the present pilot study.
Typ studie
Zápis (Aktuální)
Fáze
- Nelze použít
Kontakty a umístění
Studijní místa
-
-
-
Seoul, Korejská republika, 03722
- Severance Hospital, Yonsei University
-
-
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Popis
Inclusion Criteria:
- patients who are at least 20 years of age
- patients who require endoscopic ultrasound-guided fine needle aspiration cytology or biopsy because of pancreatic or peripancreatic solid mass.
Exclusion Criteria:
- Cystic pancreatic mass in imaging tests such as CT or MRI or US
- haemodynamically unstable patients
- severe coagulopathy (international normalized ratio [INR] > 1.5 or platelet count < 50,000 cells/cubic millimeter [cmm3])
- patients unable to quit anticoagulant/anti-platelet therapy
- pregnancy
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Diagnostický
- Přidělení: N/A
- Intervenční model: Přiřazení jedné skupiny
- Maskování: Žádné (otevřený štítek)
Zbraně a zásahy
Skupina účastníků / Arm |
Intervence / Léčba |
|---|---|
|
Experimentální: Intervention group
EUS-FNB using 20-gauge procore needle
|
The investigators will prospectively collect data base including patients who underwent EUS-guided biopsy with the 20-gauge ProCore histology needle for the evaluation of Pancreatic solid mass. EUS procedures will be performed under sedation with linear echoendoscopes. Once the lesion will be penetrated, the stylet will be removed, and suction will be applied for 10 to 20 seconds by using a 10-ml syringe while moving the needle to and fro. All samples will processed at the pathology departments for histological analysis with documentation.
Ostatní jména:
|
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Procurement of the histologic core
Časové okno: 7 days after the procedure
|
The sample quality is evaluated as optimal for histological evaluation; the presence of optimal histological core including recognizable structures
|
7 days after the procedure
|
|
Diagnostic accuracy
Časové okno: 7 days after the procedure
|
[Standard diagnosis]
|
7 days after the procedure
|
Sekundární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Technical success
Časové okno: 7 days after the procedure
|
Technical failure is defined as malfunction of the needle before the investigators reached a diagnosis
|
7 days after the procedure
|
Spolupracovníci a vyšetřovatelé
Sponzor
Publikace a užitečné odkazy
Obecné publikace
- Siddiqui UD, Rossi F, Rosenthal LS, Padda MS, Murali-Dharan V, Aslanian HR. EUS-guided FNA of solid pancreatic masses: a prospective, randomized trial comparing 22-gauge and 25-gauge needles. Gastrointest Endosc. 2009 Dec;70(6):1093-7. doi: 10.1016/j.gie.2009.05.037. Epub 2009 Jul 28.
- Lee JH, Stewart J, Ross WA, Anandasabapathy S, Xiao L, Staerkel G. Blinded prospective comparison of the performance of 22-gauge and 25-gauge needles in endoscopic ultrasound-guided fine needle aspiration of the pancreas and peri-pancreatic lesions. Dig Dis Sci. 2009 Oct;54(10):2274-81. doi: 10.1007/s10620-009-0906-1. Epub 2009 Aug 11.
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Aktuální)
Primární dokončení (Aktuální)
Dokončení studie (Aktuální)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Odhad)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Další identifikační čísla studie
- 4-2016-0429
Plán pro data jednotlivých účastníků (IPD)
Plánujete sdílet data jednotlivých účastníků (IPD)?
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .
Klinické studie na 20-gauge ProCore FNB needle
-
Seung Bae YoonSeoul St. Mary's HospitalDokončenoNovotvary pankreatuKorejská republika
-
Société Française d'Endoscopie DigestiveDokončenoNádor pankreatu | PropíchnoutFrancie