Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Yield Rate for Procurement the Histologic Core With Endoscopic Ultrasound-guided Fine Needle Biopsy With 20-gauge Ultrasound Biopsy Needles for Solid Pancreatic Masses: Pilot Study

17 de mayo de 2018 actualizado por: Yonsei University
To investigate the technical feasibility and diagnostic yield of new 20-gauge Procore needle for EUS-guided fine needle biopsy in pancreatic solid lesions.

Descripción general del estudio

Descripción detallada

Pancreatic ductal adenocarcinoma is the fourth cause of death in the Western world. Surgery remains the only treatment offering an advantage in terms of overall survival (5-year survival range, 15-25%), but unfortunately only 10-20% of patients present resectable disease at the time of diagnosis.

Regarding the diagnosis of pancreatic cancer, proper tool with high diagnostic yield is very important. The investigators investigated the technical feasibility and diagnostic yield of recent-developed new 20-gauge Procore needle for EUS-guided fine needle biopsy in pancreatic solid lesions.

The investigators applied the 20-gauge procore needle for EUS-guided fine needle biopsy in the diagnosis of pancreatic solid mass. A total of 30 patients will be enrolled for the present pilot study.

Tipo de estudio

Intervencionista

Inscripción (Actual)

30

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

20 años y mayores (Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

No

Géneros elegibles para el estudio

Todos

Descripción

Inclusion Criteria:

  • patients who are at least 20 years of age
  • patients who require endoscopic ultrasound-guided fine needle aspiration cytology or biopsy because of pancreatic or peripancreatic solid mass.

Exclusion Criteria:

  • Cystic pancreatic mass in imaging tests such as CT or MRI or US
  • haemodynamically unstable patients
  • severe coagulopathy (international normalized ratio [INR] > 1.5 or platelet count < 50,000 cells/cubic millimeter [cmm3])
  • patients unable to quit anticoagulant/anti-platelet therapy
  • pregnancy

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Diagnóstico
  • Asignación: N / A
  • Modelo Intervencionista: Asignación de un solo grupo
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: Intervention group
EUS-FNB using 20-gauge procore needle

The investigators will prospectively collect data base including patients who underwent EUS-guided biopsy with the 20-gauge ProCore histology needle for the evaluation of Pancreatic solid mass.

EUS procedures will be performed under sedation with linear echoendoscopes. Once the lesion will be penetrated, the stylet will be removed, and suction will be applied for 10 to 20 seconds by using a 10-ml syringe while moving the needle to and fro. All samples will processed at the pathology departments for histological analysis with documentation.

Otros nombres:
  • 20G Echotip ProCore Fine Needle Biopsy (FNB) device(Echotip ProCore; Cook Endoscopy Inc, Limerick, Ireland)

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Procurement of the histologic core
Periodo de tiempo: 7 days after the procedure
The sample quality is evaluated as optimal for histological evaluation; the presence of optimal histological core including recognizable structures
7 days after the procedure
Diagnostic accuracy
Periodo de tiempo: 7 days after the procedure

[Standard diagnosis]

  • In operated patients; based on the surgical resection specimen
  • In non-operated patients; based on the conclusions of the diagnostic work-up and confirmed by a compatible clinical disease course
7 days after the procedure

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Technical success
Periodo de tiempo: 7 days after the procedure
Technical failure is defined as malfunction of the needle before the investigators reached a diagnosis
7 days after the procedure

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Publicaciones y enlaces útiles

La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

11 de julio de 2016

Finalización primaria (Actual)

10 de julio de 2017

Finalización del estudio (Actual)

10 de julio de 2017

Fechas de registro del estudio

Enviado por primera vez

10 de enero de 2017

Primero enviado que cumplió con los criterios de control de calidad

10 de enero de 2017

Publicado por primera vez (Estimar)

11 de enero de 2017

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

22 de mayo de 2018

Última actualización enviada que cumplió con los criterios de control de calidad

17 de mayo de 2018

Última verificación

1 de mayo de 2018

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • 4-2016-0429

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

NO

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Ensayos clínicos sobre Cancer de pancreas

Ensayos clínicos sobre 20-gauge ProCore FNB needle

Suscribir