- ICH GCP
- Registr klinických studií v USA
- Klinická studie NCT07607977
Exploring Biomarkers in the Heat and Moisture Exchange Filters (HMEPRO)
When patients undergo major surgery, they are connected to a ventilator during anesthesia. A heat and moisture exchange filter (HME filter) is routinely placed in the ventilator tubing to ensure that the inhaled air is warm and humidified. Today, HME filters are used routinely in all ventilator treatments. They are typically replaced once a day and discarded as regular waste after use.
The purpose of this study is to investigate whether HME filters contain proteins and small biological particles from the patient's exhaled air.
Přehled studie
Postavení
Podmínky
Typ studie
Zápis (Odhadovaný)
Kontakty a umístění
Studijní kontakt
- Jméno: Inger L Gade, PhD
- Telefonní číslo: +45 20843941
- E-mail: inlg@rn.dk
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
- Dospělý
- Starší dospělý
Přijímá zdravé dobrovolníky
Metoda odběru vzorků
Studijní populace
Popis
Inclusion Criteria:
- ≥18 years, able to understand study information in Danish.
- Admitted for elective surgery for non-malignant conditions with either intravenous or inhalation anaesthesia and invasive mechanical ventilation according to standard practice.
- Expected invasive mechanical ventilation > 1 hour.
- Possess legal capacity.
- Informed, signed consent is obtained.
Exclusion Criteria:
- Patients who are transferred to the ICU for continuous invasive mechanical ventilation after end of elective surgery.
- Known chronic lung disease.
Studijní plán
Jak je studie koncipována?
Detaily designu
Kohorty a intervence
Skupina / kohorta |
|---|
|
Elective surgery patients with expected mechanical ventialtion > 2 hours
|
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Total endogenous protein amount captured in HME filters measured by standard biochemical assays.
Časové okno: Through study completion, an average of 3 months.
|
Quantification of the total amount of endogenous proteins recovered from heat moisture exchange (HME) filters using Biuret based analysis.
|
Through study completion, an average of 3 months.
|
Sekundární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Protein molecular weight and isoelectric point distribution in proteins captured by HME filters.
Časové okno: Through study completion, an average of 3 months.
|
Distribution and representation of captured proteins according to molecular weight and isoelectric point characteristics determined by proteomic analysis.
|
Through study completion, an average of 3 months.
|
Další výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Between-subject variation in exhaled breath protein concentration measured by proteomic analysis.
Časové okno: Through study completion, an average of 3 months.
|
Variation in protein concentration across HME filter samples collected from different participants, measured using protein quantification methods.
|
Through study completion, an average of 3 months.
|
Spolupracovníci a vyšetřovatelé
Sponzor
Publikace a užitečné odkazy
Obecné publikace
- Gade IL, Bodilsen J, Mariager T, Hertz S, Duerlund LS, Holm CK, Madsen PH, Bennike TB, Honore B. Exhaled breath protein composition in patients hospitalised during the first wave of COVID-19. J Breath Res. 2025 May 16;19(3). doi: 10.1088/1752-7163/add617.
- Gade IL, Riddersholm SJ, Stilling-Vinther T, Brondum RF, Bennike TB, Honore B. A clinical proteomics study of exhaled breath condensate and biomarkers for pulmonary embolism. J Breath Res. 2023 Nov 17;18(1). doi: 10.1088/1752-7163/ad0aaa.
- McNeil JB, Shaver CM, Kerchberger VE, Russell DW, Grove BS, Warren MA, Wickersham NE, Ware LB, McDonald WH, Bastarache JA. Novel Method for Noninvasive Sampling of the Distal Airspace in Acute Respiratory Distress Syndrome. Am J Respir Crit Care Med. 2018 Apr 15;197(8):1027-1035. doi: 10.1164/rccm.201707-1474OC.
- Bastarache JA, McNeil JB, Plosa EJ, Sucre JS, Kerchberger VE, Habegger LE, Weddle E, Sullivan B, Meegan JE, Wickersham NE, Shaver CM, Ware LB. Standardization of methods for sampling the distal airspace in mechanically ventilated patients using heat moisture exchange filter fluid. Am J Physiol Lung Cell Mol Physiol. 2021 May 1;320(5):L785-L790. doi: 10.1152/ajplung.00595.2020. Epub 2021 Mar 3.
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Aktuální)
Primární dokončení (Odhadovaný)
Dokončení studie (Odhadovaný)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další identifikační čísla studie
- F2025-193
- N-20250044 (Jiný identifikátor: North Denmark Regional Research Ethics Committee)
Plán pro data jednotlivých účastníků (IPD)
Plánujete sdílet data jednotlivých účastníků (IPD)?
Popis plánu IPD
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .
Klinické studie na Zánět dýchacích cest
-
Onze Lieve Vrouw HospitalUniversiteit Antwerpen; MSD Belgium BVBADokončenoRespirator-Gated Imaging TechnikyBelgie