Effect of Simethicone on Colon Preparation During Water Exchange Colonoscopy
23. června 2026 aktualizováno: Dalin Tzu Chi General Hospital
Effects of Simethicone on Colon Preparation in Water Exchange Colonoscopies: a Randomized Controlled Study
Background: Colonoscopy reduces colorectal cancer mortality by enabling early detection and removal of adenomas.
Its effectiveness, however, depends heavily on bowel preparation quality and mucosal visibility.
Simethicone, an anti-foaming agent, decreases intraluminal bubbles and improves visualization; studies in conventional air-insufflation colonoscopy generally show benefits for cleanliness and patient comfort, but evidence in water-exchange (WE) colonoscopy remains limited.Objective: To evaluate whether adding oral simethicone to a split-dose polyethylene glycol (PEG) regimen further improves bowel cleanliness and procedural performance in WE colonoscopy.Methods: Adults undergoing outpatient colonoscopy will be randomly assigned (1:1) to a simethicone group or a control group, with a planned enrollment of 180 participants.
All procedures will use the WE insertion technique, and endoscopists will be blinded to group allocation.
The primary endpoint is the Boston Bowel Preparation Scale (BBPS); adequate preparation is defined as a total score ≥6 with all segment scores ≥2.
Secondary endpoints include bubble score and CEBuS, adenoma detection rate (ADR), polyp detection rate (PDR), cecal intubation rate and time, withdrawal time, volume of water used and flushing/irrigation metrics, and patient-reported tolerability and satisfaction.Expected Results: Compared with PEG alone, adding simethicone is expected to (1) increase the proportion of adequate BBPS preparations, (2) reduce bubble coverage, (3) maintain or potentially improve ADR/PDR, and (4) enhance patient tolerability and satisfaction.Conclusion:
If effective, this intervention would provide a simple, low-cost strategy to optimize the quality of WE colonoscopy.
Přehled studie
Postavení
Zatím nenabíráme
Podmínky
Intervence / Léčba
Typ studie
Intervenční
Zápis (Odhadovaný)
180
Fáze
- Nelze použít
Kontakty a umístění
Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.
Studijní kontakt
- Jméno: Chih -Wei Tseng
- Telefonní číslo: +886-5-2648000
- E-mail: cwtseng2@gmail.com
Kritéria účasti
Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.
Kritéria způsobilosti
Věk způsobilý ke studiu
- Dospělý
- Starší dospělý
Přijímá zdravé dobrovolníky
Ano
Popis
Inclusion Criteria:
- Consecutive patients undergoing screening, surveillance, or diagnostic colonoscopy.
- Procedures performed by participating endoscopists.
- Ability to provide written informed consent.
Exclusion Criteria:
- Colonoscopy performed using air insufflation or water immersion technique.
- History of colorectal surgery (e.g., colectomy or colostomy).
- Known or suspected colonic obstruction or severe stricture.
- Requirement for inpatient bowel preparation.
- Known allergy or hypersensitivity to simethicone.
- Unable or unwilling to provide informed consent.
Studijní plán
Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.
Jak je studie koncipována?
Detaily designu
- Primární účel: Výzkum zdravotnických služeb
- Přidělení: Randomizované
- Intervenční model: Paralelní přiřazení
- Maskování: Dvojnásobek
Zbraně a zásahy
Skupina účastníků / Arm |
Intervence / Léčba |
|---|---|
|
Aktivní komparátor: Without simethicone group
follow a bowel preparation protocol consisting of 10 mg of bisacodyl and 2 liters of PEG solution.
|
All participants followed a standardized bowel preparation protocol consisting of 10 mg of bisacodyl and 2 liters of PEG solution administered in a split-dose regimen.
|
|
Experimentální: With simethicone group
Participants received a total of 30 mL of simethicone, with 15 mL added to each 1-liter dose of polyethylene glycol (PEG) solution in the split-dose regimen.
|
All participants followed a standardized bowel preparation protocol consisting of 10 mg of bisacodyl and 2 liters of PEG solution administered in a split-dose regimen.
Participants in the simethicone group additionally received 30 mL of simethicone (600 mg), with 15 mL added to each 1-liter dose of PEG solution.
|
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Boston bowel preparation scale (BBPS)
Časové okno: At the time of colonoscopy.
|
Bowel preparation quality assessed using the Boston Bowel Preparation Scale (BBPS).
Adequate preparation is defined as a total score ≥6 with all segment scores ≥2.
|
At the time of colonoscopy.
|
Sekundární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Bubble score assessed using a 4-point bubble scale
Časové okno: During the colonoscopy procedure.
|
Bubble score assessed during colonoscopy using a 4-point scale (0-3) for each colon segment, where higher scores indicate more bubbles.
|
During the colonoscopy procedure.
|
|
Colon Endoscopic Bubble Scale(CEBuS)
Časové okno: During the colonoscopy procedure.
|
Bowel cleanliness assessed using the Colon Endoscopic Bubble Scale (CEBuS), categorized based on the percentage of mucosal surface obscured by bubbles (e.g., <5%, 5-50%, >50%).Higher scores indicate poorer visibility due to bubbles.
|
During the colonoscopy procedure.
|
|
Adenoma detection rate (ADR)
Časové okno: one week
|
one week
|
|
|
Polyp detection rate (PDR)
Časové okno: one week
|
one week
|
|
|
Cecal intubation rate
Časové okno: At the time of colonoscopy.
|
Proportion of procedures in which the cecum is successfully reached.
|
At the time of colonoscopy.
|
|
Cecal intubation time
Časové okno: During the colonoscopy procedure.
|
Time from insertion to successful cecal intubation, measured in minutes.
|
During the colonoscopy procedure.
|
|
Withdrawal time
Časové okno: During the colonoscopy procedure.
|
Time from cecal intubation to scope withdrawal, measured in minutes.
|
During the colonoscopy procedure.
|
|
Volume of water infused
Časové okno: During the procedure.
|
Total volume of water infused during colonoscopy, measured in milliliters.
|
During the procedure.
|
|
Volume of fluid aspirated
Časové okno: During the procedure
|
Total volume of fluid aspirated during colonoscopy, measured in milliliters.
|
During the procedure
|
|
Patient-reported pain score
Časové okno: Immediately after the procedure.
|
Pain assessed using a visual analog scale (VAS) ranging from 0 (no pain) to 10 (worst pain imaginable).
|
Immediately after the procedure.
|
|
Patient satisfaction score
Časové okno: Immediately after the procedure.
|
Patient satisfaction assessed using a numeric rating scale from 0 to 10, where higher scores indicate greater satisfaction.
|
Immediately after the procedure.
|
Spolupracovníci a vyšetřovatelé
Zde najdete lidi a organizace zapojené do této studie.
Sponzor
Publikace a užitečné odkazy
Osoba odpovědná za zadávání informací o studiu tyto publikace poskytuje dobrovolně. Mohou se týkat čehokoli, co souvisí se studiem.
Obecné publikace
- Tongprasert S, Sobhonslidsuk A, Rattanasiri S. Improving quality of colonoscopy by adding simethicone to sodium phosphate bowel preparation. World J Gastroenterol. 2009 Jun 28;15(24):3032-7. doi: 10.3748/wjg.15.3032.
- Sung H, Ferlay J, Siegel RL, Laversanne M, Soerjomataram I, Jemal A, Bray F. Global Cancer Statistics 2020: GLOBOCAN Estimates of Incidence and Mortality Worldwide for 36 Cancers in 185 Countries. CA Cancer J Clin. 2021 May;71(3):209-249. doi: 10.3322/caac.21660. Epub 2021 Feb 4.
- Zauber AG, Winawer SJ, O'Brien MJ, Lansdorp-Vogelaar I, van Ballegooijen M, Hankey BF, Shi W, Bond JH, Schapiro M, Panish JF, Stewart ET, Waye JD. Colonoscopic polypectomy and long-term prevention of colorectal-cancer deaths. N Engl J Med. 2012 Feb 23;366(8):687-96. doi: 10.1056/NEJMoa1100370.
- Lebwohl B, Kastrinos F, Glick M, Rosenbaum AJ, Wang T, Neugut AI. The impact of suboptimal bowel preparation on adenoma miss rates and the factors associated with early repeat colonoscopy. Gastrointest Endosc. 2011 Jun;73(6):1207-14. doi: 10.1016/j.gie.2011.01.051. Epub 2011 Apr 8.
- Cao RR, Wang L, Gao C, Pan JH, Yoshida EM, Li HY, Qi XS. Effect of oral simethicone on the quality of colonoscopy: A systematic review and meta-analysis of randomized controlled trials. J Dig Dis. 2022 Mar;23(3):134-148. doi: 10.1111/1751-2980.13084. Epub 2022 Mar 14.
- Sun M, Yang G, Wang Y. Cleaning effect and tolerance of 16 bowel preparation regimens on adult patients before colonoscopy: a network meta-analysis. Int J Colorectal Dis. 2023 Mar 11;38(1):69. doi: 10.1007/s00384-023-04355-3.
- Zhang S, Zheng D, Wang J, Wu J, Lei P, Luo Q, Wang L, Zhang B, Wang H, Cui Y, Chen M. Simethicone improves bowel cleansing with low-volume polyethylene glycol: a multicenter randomized trial. Endoscopy. 2018 Apr;50(4):412-422. doi: 10.1055/s-0043-121337. Epub 2017 Nov 13.
- Joao M, Areia M, Alves S, Elvas L, Brito D, Saraiva S, Cadime AT. The Effect of Oral Simethicone in a Bowel Preparation in a Colorectal Cancer Screening Colonoscopy Setting: A Randomized Controlled Trial. GE Port J Gastroenterol. 2023 Jun 15;31(2):116-123. doi: 10.1159/000530866. eCollection 2024 Apr.
- Bai Y, Fang J, Zhao SB, Wang D, Li YQ, Shi RH, Sun ZQ, Sun MJ, Ji F, Si JM, Li ZS. Impact of preprocedure simethicone on adenoma detection rate during colonoscopy: a multicenter, endoscopist-blinded randomized controlled trial. Endoscopy. 2018 Feb;50(2):128-136. doi: 10.1055/s-0043-119213. Epub 2017 Oct 6.
- Moolla M, Dang JT, Shaw A, Dang TNT, Tian C, Karmali S, Sultanian R. Simethicone decreases bloating and improves bowel preparation effectiveness: a systematic review and meta-analysis. Surg Endosc. 2019 Dec;33(12):3899-3909. doi: 10.1007/s00464-019-07066-5. Epub 2019 Aug 26.
- Menees SB, Elliott E, Govani S, Anastassiades C, Judd S, Urganus A, Boyce S, Schoenfeld P. The impact of bowel cleansing on follow-up recommendations in average-risk patients with a normal colonoscopy. Am J Gastroenterol. 2014 Feb;109(2):148-54. doi: 10.1038/ajg.2013.243.
- Sharma P, Burke CA, Johnson DA, Cash BD. The importance of colonoscopy bowel preparation for the detection of colorectal lesions and colorectal cancer prevention. Endosc Int Open. 2020 May;8(5):E673-E683. doi: 10.1055/a-1127-3144. Epub 2020 Apr 17.
Termíny studijních záznamů
Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.
Hlavní termíny studia
Začátek studia (Odhadovaný)
1. srpna 2026
Primární dokončení (Odhadovaný)
1. května 2028
Dokončení studie (Odhadovaný)
1. září 2028
Termíny zápisu do studia
První předloženo
3. března 2026
První předloženo, které splnilo kritéria kontroly kvality
23. června 2026
První zveřejněno (Aktuální)
29. června 2026
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
29. června 2026
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
23. června 2026
Naposledy ověřeno
1. února 2026
Více informací
Termíny související s touto studií
Klíčová slova
Další relevantní podmínky MeSH
Další identifikační čísla studie
- A11403003
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Ne
Studuje produkt zařízení regulovaný americkým úřadem FDA
Ne
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .