Clinical Trial on the Visual Function of Enhanced Monofocal and EDoF Intraocular Lenses
Randomized Clinical Trial to Evaluate the Visual Function of Enhanced Monofocal and Extended Depth of Field Intraocular Lenses
Přehled studie
Detailní popis
Primary Objective
To evaluate whether the implantation of enhanced monofocal intraocular lenses during cataract surgery results in fewer adverse visual phenomena (dysphotopsias) than the implantation of extended depth-of-field (EDoF) intraocular lenses.
Secondary Objectives
To evaluate whether there are differences in best-corrected visual acuity at various distances, contrast sensitivity, visual quality, and quality of life between patients implanted with enhanced monofocal intraocular lenses and those implanted with extended depth-of-field intraocular lenses.
To evaluate whether there are differences in best-corrected visual acuity at various distances, contrast sensitivity, visual quality, and quality of life among the four enhanced monofocal intraocular lenses analyzed in the present study.
To evaluate whether there are differences in best-corrected visual acuity at various distances, contrast sensitivity, visual quality, and quality of life between the two extended depth-of-field intraocular lenses analyzed in the present study.
Typ studie
Zápis (Odhadovaný)
Fáze
- Nelze použít
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
- Dospělý
- Starší dospělý
Přijímá zdravé dobrovolníky
Popis
INCLUSION CRITERIA:
- Patients with bilateral cataracts at different stages of development.
- Patients with functional visual demands.
- Age between 45 and 80 years.
- Male or female sex.
- Ability to provide informed consent.
EXCLUSION CRITERIA:
Preoperative Exclusion Criteria
• Medical criteria:
Corneal astigmatism greater than 1.0 diopter. Pre-existing ocular pathology. Previous refractive surgery. Previous corneal or intraocular implant. Poor general health status or potentially reduced neuroadaptation capacity due to previous stroke, Alzheimer's disease, other forms of dementia, etc.
Unrealistic postoperative visual expectations.
Intraoperative Withdrawal Criteria
- Vitreous loss.
- Pupillary trauma.
- Factors likely to affect the medium-term performance of the intraocular lens: Zonular damage, Capsulorhexis tear or injury, Capsular rupture, Endothelial damage.
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Léčba
- Přidělení: Randomizované
- Intervenční model: Paralelní přiřazení
- Maskování: Dvojnásobek
Zbraně a zásahy
Skupina účastníků / Arm |
Intervence / Léčba |
|---|---|
|
Experimentální: Group 1: Implantation of the Clareon Vivity intraocular lens
EDoF IOL
|
Implantation of intraocular lens
|
|
Experimentální: Group 2: Implantation of the TECNIS Eyhance intraocular lens
Enhanced monofocal IOL
|
Implantation of intraocular lens
|
|
Experimentální: Group 3: Implantation of the RayOne EMV intraocular lens
Enhanced monofocal IOL
|
Implantation of intraocular lens
|
|
Experimentální: Group 4: Implantation of the IsoPure Serenity intraocular lens
Enhanced monofocal IOL
|
Implantation of intraocular lens
|
|
Experimentální: Group 5: Implantation of the Vivinex Impress intraocular lens
Enhanced monofocal IOL
|
Implantation of intraocular lens
|
|
Experimentální: Group 6: Implantation of the TECNIS PureSee intraocular lens
EDoF IOL
|
Implantation of intraocular lens
|
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Visual acuity at different distances
Časové okno: 1 month, 3 months, 6 months
|
Far vision, intermediate vision, near vision
|
1 month, 3 months, 6 months
|
|
Dysphotopsias
Časové okno: 1 month, 3 months, 6 months
|
Dysphotopsias after the IOL implantation
|
1 month, 3 months, 6 months
|
Spolupracovníci a vyšetřovatelé
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Odhadovaný)
Primární dokončení (Odhadovaný)
Dokončení studie (Odhadovaný)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další relevantní podmínky MeSH
Další identifikační čísla studie
- IIBSP-LEN-2024-38
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .
Klinické studie na Intraocular lens
-
Biotech Healthcare Holding GmbhNáborMyopie, degenerativní | Myopický astigmatismus | Myopie, středníNěmecko, Indie
-
CooperVision International Limited (CVIL)Centre for Ocular Research & Education, CanadaNábor
-
CooperVision International Limited (CVIL)University of California, BerkeleyNábor
-
Essilor InternationalDokončeno
-
Menicon Co., Ltd.DokončenoZraková ostrost | Kontaktní čočky ComfortKanada
-
Shahid Beheshti UniversityNeznámýKeratokonusÍrán, Islámská republika
-
Johns Hopkins UniversityNational Eye Institute (NEI)NáborRetinální vaskulární porucha | Diabetická retinopatie | Okluze retinální žíly | Hypertenze, esenciálníSpojené státy
-
Yonsei UniversityDokončenoPresbyopieKorejská republika
-
Bausch & Lomb IncorporatedDokončeno