- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT07715071
Clinical Trial on the Visual Function of Enhanced Monofocal and EDoF Intraocular Lenses
Randomized Clinical Trial to Evaluate the Visual Function of Enhanced Monofocal and Extended Depth of Field Intraocular Lenses
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Descripción detallada
Primary Objective
To evaluate whether the implantation of enhanced monofocal intraocular lenses during cataract surgery results in fewer adverse visual phenomena (dysphotopsias) than the implantation of extended depth-of-field (EDoF) intraocular lenses.
Secondary Objectives
To evaluate whether there are differences in best-corrected visual acuity at various distances, contrast sensitivity, visual quality, and quality of life between patients implanted with enhanced monofocal intraocular lenses and those implanted with extended depth-of-field intraocular lenses.
To evaluate whether there are differences in best-corrected visual acuity at various distances, contrast sensitivity, visual quality, and quality of life among the four enhanced monofocal intraocular lenses analyzed in the present study.
To evaluate whether there are differences in best-corrected visual acuity at various distances, contrast sensitivity, visual quality, and quality of life between the two extended depth-of-field intraocular lenses analyzed in the present study.
Tipo de estudio
Inscripción (Estimado)
Fase
- No aplica
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
- Adulto
- Adulto Mayor
Acepta Voluntarios Saludables
Descripción
INCLUSION CRITERIA:
- Patients with bilateral cataracts at different stages of development.
- Patients with functional visual demands.
- Age between 45 and 80 years.
- Male or female sex.
- Ability to provide informed consent.
EXCLUSION CRITERIA:
Preoperative Exclusion Criteria
• Medical criteria:
Corneal astigmatism greater than 1.0 diopter. Pre-existing ocular pathology. Previous refractive surgery. Previous corneal or intraocular implant. Poor general health status or potentially reduced neuroadaptation capacity due to previous stroke, Alzheimer's disease, other forms of dementia, etc.
Unrealistic postoperative visual expectations.
Intraoperative Withdrawal Criteria
- Vitreous loss.
- Pupillary trauma.
- Factors likely to affect the medium-term performance of the intraocular lens: Zonular damage, Capsulorhexis tear or injury, Capsular rupture, Endothelial damage.
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Tratamiento
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Doble
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Experimental: Group 1: Implantation of the Clareon Vivity intraocular lens
EDoF IOL
|
Implantation of intraocular lens
|
|
Experimental: Group 2: Implantation of the TECNIS Eyhance intraocular lens
Enhanced monofocal IOL
|
Implantation of intraocular lens
|
|
Experimental: Group 3: Implantation of the RayOne EMV intraocular lens
Enhanced monofocal IOL
|
Implantation of intraocular lens
|
|
Experimental: Group 4: Implantation of the IsoPure Serenity intraocular lens
Enhanced monofocal IOL
|
Implantation of intraocular lens
|
|
Experimental: Group 5: Implantation of the Vivinex Impress intraocular lens
Enhanced monofocal IOL
|
Implantation of intraocular lens
|
|
Experimental: Group 6: Implantation of the TECNIS PureSee intraocular lens
EDoF IOL
|
Implantation of intraocular lens
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Visual acuity at different distances
Periodo de tiempo: 1 month, 3 months, 6 months
|
Far vision, intermediate vision, near vision
|
1 month, 3 months, 6 months
|
|
Dysphotopsias
Periodo de tiempo: 1 month, 3 months, 6 months
|
Dysphotopsias after the IOL implantation
|
1 month, 3 months, 6 months
|
Colaboradores e Investigadores
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Estimado)
Finalización primaria (Estimado)
Finalización del estudio (Estimado)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- IIBSP-LEN-2024-38
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .
Ensayos clínicos sobre Intraocular lens
-
The Hong Kong Polytechnic UniversityBausch & Lomb IncorporatedActivo, no reclutando
-
University of Texas Southwestern Medical CenterRetirado
-
Carl Zeiss Meditec AGTerminado
-
Abbott Medical OpticsTerminado
-
Saglik Bilimleri UniversitesiTerminadoPresión intraocular | Hernia inguinalTurquía (Türkiye)
-
Glostrup University Hospital, CopenhagenTerminado
-
Prim. Prof. Dr. Oliver Findl, MBADesconocidoCatarata | AstigmatismoAustria
-
Abbott Medical OpticsTerminadoCatarataEstados Unidos, Reino Unido
-
Hospital Civil de GuadalajaraDesconocidoPresión intraocular | Aumento de la presión intracraneal | Niños, Solo | Trauma, CerebroMéxico