- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT07715071
Clinical Trial on the Visual Function of Enhanced Monofocal and EDoF Intraocular Lenses
Randomized Clinical Trial to Evaluate the Visual Function of Enhanced Monofocal and Extended Depth of Field Intraocular Lenses
Przegląd badań
Szczegółowy opis
Primary Objective
To evaluate whether the implantation of enhanced monofocal intraocular lenses during cataract surgery results in fewer adverse visual phenomena (dysphotopsias) than the implantation of extended depth-of-field (EDoF) intraocular lenses.
Secondary Objectives
To evaluate whether there are differences in best-corrected visual acuity at various distances, contrast sensitivity, visual quality, and quality of life between patients implanted with enhanced monofocal intraocular lenses and those implanted with extended depth-of-field intraocular lenses.
To evaluate whether there are differences in best-corrected visual acuity at various distances, contrast sensitivity, visual quality, and quality of life among the four enhanced monofocal intraocular lenses analyzed in the present study.
To evaluate whether there are differences in best-corrected visual acuity at various distances, contrast sensitivity, visual quality, and quality of life between the two extended depth-of-field intraocular lenses analyzed in the present study.
Typ studiów
Zapisy (Szacowany)
Faza
- Nie dotyczy
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
- Dorosły
- Starszy dorosły
Akceptuje zdrowych ochotników
Opis
INCLUSION CRITERIA:
- Patients with bilateral cataracts at different stages of development.
- Patients with functional visual demands.
- Age between 45 and 80 years.
- Male or female sex.
- Ability to provide informed consent.
EXCLUSION CRITERIA:
Preoperative Exclusion Criteria
• Medical criteria:
Corneal astigmatism greater than 1.0 diopter. Pre-existing ocular pathology. Previous refractive surgery. Previous corneal or intraocular implant. Poor general health status or potentially reduced neuroadaptation capacity due to previous stroke, Alzheimer's disease, other forms of dementia, etc.
Unrealistic postoperative visual expectations.
Intraoperative Withdrawal Criteria
- Vitreous loss.
- Pupillary trauma.
- Factors likely to affect the medium-term performance of the intraocular lens: Zonular damage, Capsulorhexis tear or injury, Capsular rupture, Endothelial damage.
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Leczenie
- Przydział: Randomizowane
- Model interwencyjny: Przydział równoległy
- Maskowanie: Podwójnie
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Eksperymentalny: Group 1: Implantation of the Clareon Vivity intraocular lens
EDoF IOL
|
Implantation of intraocular lens
|
|
Eksperymentalny: Group 2: Implantation of the TECNIS Eyhance intraocular lens
Enhanced monofocal IOL
|
Implantation of intraocular lens
|
|
Eksperymentalny: Group 3: Implantation of the RayOne EMV intraocular lens
Enhanced monofocal IOL
|
Implantation of intraocular lens
|
|
Eksperymentalny: Group 4: Implantation of the IsoPure Serenity intraocular lens
Enhanced monofocal IOL
|
Implantation of intraocular lens
|
|
Eksperymentalny: Group 5: Implantation of the Vivinex Impress intraocular lens
Enhanced monofocal IOL
|
Implantation of intraocular lens
|
|
Eksperymentalny: Group 6: Implantation of the TECNIS PureSee intraocular lens
EDoF IOL
|
Implantation of intraocular lens
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Visual acuity at different distances
Ramy czasowe: 1 month, 3 months, 6 months
|
Far vision, intermediate vision, near vision
|
1 month, 3 months, 6 months
|
|
Dysphotopsias
Ramy czasowe: 1 month, 3 months, 6 months
|
Dysphotopsias after the IOL implantation
|
1 month, 3 months, 6 months
|
Współpracownicy i badacze
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Szacowany)
Zakończenie podstawowe (Szacowany)
Ukończenie studiów (Szacowany)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- IIBSP-LEN-2024-38
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .
Badania kliniczne na Zaćma
-
RxSight, Inc.Rejestracja na zaproszenie
-
Adaptilens, Inc.Jeszcze nie rekrutacjaAphakia Cataract
Badania kliniczne na Intraocular lens
-
Tianjin Medical University Eye HospitalJeszcze nie rekrutacjaPostępująca krótkowzroczność | Miopia dziecięca | Postęp krótkowzroczności związany z ortokorekcją
-
CooperVision International Limited (CVIL)University of California, BerkeleyRekrutacyjnyDalekowzroczność starczaStany Zjednoczone
-
McGill UniversityZakończony
-
Alcon ResearchZakończonyWilgoć soczewek kontaktowychStany Zjednoczone
-
Kingston Health Sciences CentreProvidence Health & ServicesJeszcze nie rekrutacjaŁagodne upośledzenie funkcji poznawczychKanada
-
Centro de Miopía Fernández-VelázquezAktywny, nie rekrutujący
-
Vistakon PharmaceuticalsZakończonyAlergiczne zapalenie spojówekStany Zjednoczone
-
Korea UniversitySamsung Medical Center; Asan Medical Center; Seoul National University Hospital; Korea University Anam Hospital i inni współpracownicyRekrutacyjnyMarskość wątroby | Rak wątrobowokomórkowy | NadzórRepublika Korei