Clinical Application of a Novel Corneal Biomechanical Device in Refractive Surgery
A Study of the Clinical Applications of a Novel Corneal Biomechanical Device in Refractive Surgery
This study aims to evaluate the accuracy of corneal Young's modulus measurements (E_CID and E_Steady-State) obtained using a steady-state corneal biomechanical measurement device in patients scheduled to undergo refractive surgery and to explore their potential applications in assisting refractive surgical procedures.
Studieoversigt
Status
Betingelser
Undersøgelsestype
Tilmelding (Anslået)
Fase
- Ikke anvendelig
Kontakter og lokationer
Studiesteder
-
-
Tianjin Municipality
-
Tianjin, Tianjin Municipality, Kina, 300020
- Rekruttering
- Tianjin Eye Hospital
-
Kontakt:
- Ruisi Xie
- Telefonnummer: 86+18202581417
- E-mail: xieruisi2000@163.com
-
-
Deltagelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
- Barn
- Voksen
- Ældre voksen
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Beskrivelse
Inclusion Criteria:
- Best corrected visual acuity (BCVA) ≥ 20/20;
- No other eye diseases except myopia and astigmatism;
- The cornea was transparent, and there was no cloud or pannus;
Exclusion Criteria:
- Corneal disease;
- Ocular trauma;
- Previous ocular surgery;
- Any anterior segment diseases except cataract;
- Patients were required to stop wearing soft contact lenses for at least 2 weeks and rigid contact lenses for at least 4 weeks before examination;
- Pregnant and lactating women;
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Behandling
- Tildeling: Randomiseret
- Interventionel model: Parallel tildeling
- Maskning: Tredobbelt
Våben og indgreb
Deltagergruppe / Arm |
Intervention / Behandling |
|---|---|
|
Aktiv komparator: Normal group
|
Morphological and biomechanical parameters were obtained by Pentacam and Corvis ST |
|
Eksperimentel: Steady-State Corneal Biomechanical Measurement Group
|
Participants wear negative-pressure goggles, and a pressure test is performed to ensure an adequate seal. They then position their chin on the chinrest and fixate on a target while the operator aligns the imaging system with the cornea. The device applies controlled negative pressure and captures corneal deformation images using a Scheimpflug camera, with a coaxial imaging system assisting in alignment and monitoring eye movements. Following data acquisition, the software analyzes corneal biomechanical parameters and generates an assessment report. |
Hvad måler undersøgelsen?
Primære resultatmål
Resultatmål |
Tidsramme |
|---|---|
|
Synsstyrke
Tidsramme: Et år
|
Et år
|
|
Postoperative residual refractive error
Tidsramme: One year
|
One year
|
Samarbejdspartnere og efterforskere
Sponsor
Datoer for undersøgelser
Studer store datoer
Studiestart (Faktiske)
Primær færdiggørelse (Anslået)
Studieafslutning (Anslået)
Datoer for studieregistrering
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Andre undersøgelses-id-numre
- KY-2026036
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .