Clinical Application of a Novel Corneal Biomechanical Device in Refractive Surgery
A Study of the Clinical Applications of a Novel Corneal Biomechanical Device in Refractive Surgery
This study aims to evaluate the accuracy of corneal Young's modulus measurements (E_CID and E_Steady-State) obtained using a steady-state corneal biomechanical measurement device in patients scheduled to undergo refractive surgery and to explore their potential applications in assisting refractive surgical procedures.
Studieoversikt
Status
Forhold
Studietype
Registrering (Antatt)
Fase
- Ikke aktuelt
Kontakter og plasseringer
Studiesteder
-
-
Tianjin Municipality
-
Tianjin, Tianjin Municipality, Kina, 300020
- Rekruttering
- Tianjin Eye Hospital
-
Ta kontakt med:
- Ruisi Xie
- Telefonnummer: 86+18202581417
- E-post: xieruisi2000@163.com
-
-
Deltakelseskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
- Barn
- Voksen
- Eldre voksen
Tar imot friske frivillige
Kjønn som er kvalifisert for studier
Beskrivelse
Inclusion Criteria:
- Best corrected visual acuity (BCVA) ≥ 20/20;
- No other eye diseases except myopia and astigmatism;
- The cornea was transparent, and there was no cloud or pannus;
Exclusion Criteria:
- Corneal disease;
- Ocular trauma;
- Previous ocular surgery;
- Any anterior segment diseases except cataract;
- Patients were required to stop wearing soft contact lenses for at least 2 weeks and rigid contact lenses for at least 4 weeks before examination;
- Pregnant and lactating women;
Studieplan
Hvordan er studiet utformet?
Designdetaljer
- Primært formål: Behandling
- Tildeling: Randomisert
- Intervensjonsmodell: Parallell tildeling
- Masking: Trippel
Våpen og intervensjoner
Deltakergruppe / Arm |
Intervensjon / Behandling |
|---|---|
|
Aktiv komparator: Normal group
|
Morphological and biomechanical parameters were obtained by Pentacam and Corvis ST |
|
Eksperimentell: Steady-State Corneal Biomechanical Measurement Group
|
Participants wear negative-pressure goggles, and a pressure test is performed to ensure an adequate seal. They then position their chin on the chinrest and fixate on a target while the operator aligns the imaging system with the cornea. The device applies controlled negative pressure and captures corneal deformation images using a Scheimpflug camera, with a coaxial imaging system assisting in alignment and monitoring eye movements. Following data acquisition, the software analyzes corneal biomechanical parameters and generates an assessment report. |
Hva måler studien?
Primære resultatmål
Resultatmål |
Tidsramme |
|---|---|
|
Synsskarphet
Tidsramme: Ett år
|
Ett år
|
|
Postoperative residual refractive error
Tidsramme: One year
|
One year
|
Samarbeidspartnere og etterforskere
Sponsor
Studierekorddatoer
Studer hoveddatoer
Studiestart (Faktiske)
Primær fullføring (Antatt)
Studiet fullført (Antatt)
Datoer for studieregistrering
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Faktiske)
Oppdateringer av studieposter
Sist oppdatering lagt ut (Faktiske)
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Andre studie-ID-numre
- KY-2026036
Legemiddel- og utstyrsinformasjon, studiedokumenter
Studerer et amerikansk FDA-regulert medikamentprodukt
Studerer et amerikansk FDA-regulert enhetsprodukt
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .