Clinical Application of a Novel Corneal Biomechanical Device in Refractive Surgery
A Study of the Clinical Applications of a Novel Corneal Biomechanical Device in Refractive Surgery
This study aims to evaluate the accuracy of corneal Young's modulus measurements (E_CID and E_Steady-State) obtained using a steady-state corneal biomechanical measurement device in patients scheduled to undergo refractive surgery and to explore their potential applications in assisting refractive surgical procedures.
Studie Overzicht
Toestand
Studietype
Inschrijving (Geschat)
Fase
- Niet toepasbaar
Contacten en locaties
Studie Locaties
-
-
Tianjin Municipality
-
Tianjin, Tianjin Municipality, China, 300020
- Werving
- Tianjin Eye Hospital
-
Contact:
- Ruisi Xie
- Telefoonnummer: 86+18202581417
- E-mail: xieruisi2000@163.com
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
- Kind
- Volwassen
- Oudere volwassene
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- Best corrected visual acuity (BCVA) ≥ 20/20;
- No other eye diseases except myopia and astigmatism;
- The cornea was transparent, and there was no cloud or pannus;
Exclusion Criteria:
- Corneal disease;
- Ocular trauma;
- Previous ocular surgery;
- Any anterior segment diseases except cataract;
- Patients were required to stop wearing soft contact lenses for at least 2 weeks and rigid contact lenses for at least 4 weeks before examination;
- Pregnant and lactating women;
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Behandeling
- Toewijzing: Gerandomiseerd
- Interventioneel model: Parallelle opdracht
- Masker: Verdrievoudigen
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Actieve vergelijker: Normal group
|
Morphological and biomechanical parameters were obtained by Pentacam and Corvis ST |
|
Experimenteel: Steady-State Corneal Biomechanical Measurement Group
|
Participants wear negative-pressure goggles, and a pressure test is performed to ensure an adequate seal. They then position their chin on the chinrest and fixate on a target while the operator aligns the imaging system with the cornea. The device applies controlled negative pressure and captures corneal deformation images using a Scheimpflug camera, with a coaxial imaging system assisting in alignment and monitoring eye movements. Following data acquisition, the software analyzes corneal biomechanical parameters and generates an assessment report. |
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Tijdsspanne |
|---|---|
|
Gezichtsscherpte
Tijdsspanne: Een jaar
|
Een jaar
|
|
Postoperative residual refractive error
Tijdsspanne: One year
|
One year
|
Medewerkers en onderzoekers
Sponsor
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Geschat)
Studie voltooiing (Geschat)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Andere studie-ID-nummers
- KY-2026036
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .