- ICH GCP
- US-Register für klinische Studien
- Klinische Studie NCT07928973
Clinical Application of a Novel Corneal Biomechanical Device in Refractive Surgery
A Study of the Clinical Applications of a Novel Corneal Biomechanical Device in Refractive Surgery
This study aims to evaluate the accuracy of corneal Young's modulus measurements (E_CID and E_Steady-State) obtained using a steady-state corneal biomechanical measurement device in patients scheduled to undergo refractive surgery and to explore their potential applications in assisting refractive surgical procedures.
Studienübersicht
Status
Bedingungen
Studientyp
Einschreibung (Geschätzt)
Phase
- Unzutreffend
Kontakte und Standorte
Studienorte
-
-
Tianjin Municipality
-
Tianjin, Tianjin Municipality, China, 300020
- Rekrutierung
- Tianjin Eye Hospital
-
Kontakt:
- Ruisi Xie
- Telefonnummer: 86+18202581417
- E-Mail: xieruisi2000@163.com
-
-
Teilnahmekriterien
Zulassungskriterien
Studienberechtigtes Alter
- Kind
- Erwachsene
- Älterer Erwachsener
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Beschreibung
Inclusion Criteria:
- Best corrected visual acuity (BCVA) ≥ 20/20;
- No other eye diseases except myopia and astigmatism;
- The cornea was transparent, and there was no cloud or pannus;
Exclusion Criteria:
- Corneal disease;
- Ocular trauma;
- Previous ocular surgery;
- Any anterior segment diseases except cataract;
- Patients were required to stop wearing soft contact lenses for at least 2 weeks and rigid contact lenses for at least 4 weeks before examination;
- Pregnant and lactating women;
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Behandlung
- Zuteilung: Zufällig
- Interventionsmodell: Parallele Zuordnung
- Maskierung: Verdreifachen
Waffen und Interventionen
Teilnehmergruppe / Arm |
Intervention / Behandlung |
|---|---|
|
Aktiver Komparator: Normal group
|
Morphological and biomechanical parameters were obtained by Pentacam and Corvis ST |
|
Experimental: Steady-State Corneal Biomechanical Measurement Group
|
Participants wear negative-pressure goggles, and a pressure test is performed to ensure an adequate seal. They then position their chin on the chinrest and fixate on a target while the operator aligns the imaging system with the cornea. The device applies controlled negative pressure and captures corneal deformation images using a Scheimpflug camera, with a coaxial imaging system assisting in alignment and monitoring eye movements. Following data acquisition, the software analyzes corneal biomechanical parameters and generates an assessment report. |
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Zeitfenster |
|---|---|
|
Sehschärfe
Zeitfenster: Ein Jahr
|
Ein Jahr
|
|
Postoperative residual refractive error
Zeitfenster: One year
|
One year
|
Mitarbeiter und Ermittler
Sponsor
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Primärer Abschluss (Geschätzt)
Studienabschluss (Geschätzt)
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Andere Studien-ID-Nummern
- KY-2026036
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .